HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
r SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. Lot Zone of Contribution: In
Out Acreage
Street: Commercial:___ Residential:
Village: _---
Floor Plan: #Bedrooms:
Owner: --
Address: Installer:
Phone: Phone:
Builder:
Address: Engineer:
Phone: Phone:
1. Re.uired#of copies received N/A = NO
2. Date of soils exam and .ercolation test not older than 2 years '
3. 4-5 ft of naturalI occurrin• .ervious material, above water table
4: Foundation 2 ft above hi•h •oint of road
Mat
5. Water line 10 ft from s-.tic com.onents Var Fnd: Var.:
6. Benchmark indicated and shown-NGVD if near wetlands f -
7. Se.tie tank minimum 10 ft from foundation, deck -
8. Leachin• minimum 20 ft full, I5 ft crawl, 10 ft slab Var.: __AMINE
9. Leachin• I _-
minimum 100 ft from wetlands I _
Var.:
10. Leaclun• minimum 150 ft from drinking welU25 ft irrigation well Var.:
1111111111111111111111
lt,.':,.: :„<um IO ft from .ro.eft line Var.: __
12.System meets all other setback re uirements _
13. Uses ad'ustment for maximum hiah groundwater Var.: \
14. Leaching set 4-5 ft above ad.. water or bottom of test hole Var.`
15. System not in toe or subsoil (A,B horizons)or 5' removal
16. Pro.osed contours are suitable
17. System meets slope re.uirements-min. 1/8", V."preferred 11111111111111
-
]8. S stem meets breakout re uirements PVC liner: Wall: ( -�
_
19. S.ecified tee sizes are .ro.er, aas baffle on outlet tee
20. Sewaae is under 10,000 A.d for .arcel - _
21.No oarbaoe dis.osal _
22. System ade uately sized for its intended use _-
23.Minimum 6"stone or com•acted below tank and dbox - Mil
24. Manhole covers within 6"of grade, 'um. chamber cover to grade ®-
25. Ins.ection •ort on elastic chambers/leach field1111111,1111111.1111111
26. Electrical .ermit for 'urn. chamber/Se.arate meter for du.lexes __-
27.Puma system-2"line,wee• hole,check valve, tee in dbox, •ump size -_
28. Se.tic tank/gums chamber to be factory wate .roofed111111111111.11111
29. Vent .rovided if leachin below 3 feet,under drivew ayi.arkino _MMEMINIII-
30.Buo anc calculations for-tank/sums um. chamber �_
31. En_'neer to ins•ect and certi soils:
__
32. En_'neer/Re_istered Sanitarian and Land Surve or stam.s/sianature commercial: _�
33.H-20 loading is sub-ect to vehicular traffic, : oundwater --
34.Title V A.•lication and .ermit fee, installer si• •ature
35. Foundation footing min. 2 feet above ad'usted ground water for new house --36.Deed Restriction re•uired max. oms: --
37- Check area lots for ground�vater/Label • ound eateor Assessor's Ma. dMIN
Plan reviewed by: '! (,)`