Loading...
HomeMy WebLinkAboutEngineer PlanT.O.F. EL.= 23,0'± PROPOSED EXTENSION RISER WITH COVER OVER INLET & OUTLET TO WITHIN 6" OF F.G. FINISH GRADE @ FND. EL.= 22.5'± F.G. OVER TANK EL. = 22.0'± -11-: i 4 4,:, PROPOSED 4" ._. _ �_. , _ �._ SCH. 40 PVC SEWER PIPE � r ; 3" DROP MAX 3" 9 --- _ _-__-__-_-- 2" DROP MIN ----- _- - - --- �-_-. -- ----- MIN. SLOPE '!% 14" CONTRACTOR TO PROVIDE - 'M1= SPECIFIED DROP BETWEEN INLET AND OUTLET CONTRACTOR SHALL VERIFY SIZE AND CONDITION OF EXISTING SEPTIC TANK CONTRACTOR SHALL' VERIFY CONDITION OF EXISTING TEES AND REPLACE AS NECESSARY OUTLET TEE GAS BAFFLE EXISTING 1,000 GALLON CONCRETE SEPTIC TANK SEPTIC T,�1� l�lFFll NOT TO SCALE a d a � o cn cm 4" SCHEDULE 40 PVC MIN. SLOPE INSPECTION PORT WITH ACCESS BOX TO WITHIN 3" OF F.G. PLAN FOR • • FLOORCRAWL • (THEREFORE ` .581 aX. •• • • • PROVIDE WATERTIGHT • ^ tia ��iii�ii is ii ii i..i i"i ice;. • Jolt, i r'i i • • PVC OUT TO ! • i"i i i i i ii i i i i ii i rr'ra s i l� i s i i= i'i ii it i`F �• LEACHING FACILI i� fi•i .It Ira ii ii 1ii ii i-i i!� trrli ii • �• ; •FLAT) • , �� • • -a FINISHED GRADE OVER CHAMBERS = 21.2 - 21,8' , SLOPE @ 2% MIN. GENERAL NOTES ES I. UNLESS OTHERWISE NOTED, ALL SYSTEM COMPONENTS AND CONSTRUCTION METHODS SHALL BE IN ACCORDANCE WiTH TITLE 5 OF THE STATE ENVIRONMENTAL _ CODE AND ANY APPLICABLE LOCAL RULES PROVIDE FILTER FABRIC OVER ENTIRE LEACHING FACILITY (SEE FABRIC NOTE # 1 BELOW) VP)�'i (TYP.) 7.13' 2. ANY CHANGES TO THiS PLAN MUST BE APPROVED BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 3. 4" SCHEDULE 40 PVC PIPE WITH WATER TIGHT JOINTS SHALL BE USED IN DISPOSAL SYSTEM UNLESS OTHERWISE NOTED. 4. TO PREVENT BREAKOUT, THE PROPOSED FINISHED GRADE SHALL NOT BE LESS THAN ELEVATION=19.58' FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE SAS. UNLESS A 13" 40 MIL GEOMEMBRANE LINER IS PLACE AT LEAST FIVE FEET FROM S.A.S. AND THE TOP OF THE LINER IS NOT LESS THAN THE BREAKOUT ELEVATION. SLOPE ALL SOLID PIPE-ATI DO/. MINIMUM 2.875' (34.5" )� (STONELESS SYSTEM) r 6. THS SYSTEM IS NOT DESIGNED FOR A GARBAGE DISPOSAL.) ( ) 4 CHAMBERS WIDE I. LOCAL BOARD OF HEALTH AND DESIGN ENGINEER TO BE NOTIFIED PRIOR TO BACK 11.5' FILLING WHEN SYSTEM IS NEARLY COMPLETE AND READY FOR INSPECTION. SYSTEM IS NOT TO BE BACK FILLED WITHOUT FIRST OBTAINING APPROVAL FROM BOARD OF HEALTH MIN. REQ'D AND DESIGN ENGINEER. _ PROP. (See Gen. Note #221 8. ELEVATIONS BASED ON APPROXIMATE . MEAN SEA LEVEL (MSL) DATUMSEE BENCHMARK TO BE INSTALLED ON A LEVEL STABLE GROUND WATER ELEV.= 14.50' (mottling) LOCATION AND ELEVATION SHOWN ON PLAN. BASE. FIRST TWO FEET OF OUTLET CHAMMER PROFILE CHAMBER END VIEW 9. CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS PRIOR TO CONSTRUCTION PIPES TO BE LAiD LEVEL. CROSS SECTION VIEW FILTER FABRIC NOTE#1: DRAPE THE FABRIC TO COMPLETELY COVER THE LOUVERED SIDEWALLS OF THE CHAMBERS TO , I d ,� x ,, O I R 1 U I 1 1` BOX DETAIL PREVENT SOIL INTRUSION. FABRIC: SPUN BONDED, MADE UP OF � C I�, ��1 i B- E f R: S y �'�� 1 a 1 3 NOT TO SCALE NYLON FIBERS, HYDROPHILIC IN NATURE • WEIGHT: 0.35 -1 OZ/YD2 NOT TO SCALE % �* NOTES: 1. MAGNETIC MARKING TAPE SHALL BE PLACED ALONG THE TOP N, EDGE OF EACH SEPTIC SYSTEM COMPONENT. 2. CONTRACTOR SHALL VERIFY SOIL CONDITIONS IN THE LOCATION ` ` OF THE PROPOSED LEACHING FACILITY TO ENSURE CONSISTENCY WITH TEST PIT DATA SHOWN ON THIS PLAN. W. REPORT TO ENGINEER AND LOCAL BOARD OF HEALTH IF SOILS ARE NOT CONSISTENT WITH TEST PIT DATA. rs 3. ENTIRE PROPERTY IS NOT LOCATED WITHIN A MASS DEP ZONE II. 4. SWING TIES SHOWN ON THIS PLAN ARE PROVIDED ONLY AS A COURTESY FOR THE INSTALLER. INSTALLER SHALL VERIFY SWING TIE MEASUREMENTS IN THE FIELD PRIOR TO INSTALLING THE SYSTEM. CONTRACTOR SHALL NOTIFY ENGINEER iF MEASUREMENTS APPEAR TO BE INCORRECT IN THE FIELD. I �\� Benchmarks (; Comer of Wall I Elevation = 20.36' 7 V.x 21.2 Approx. M.S.L. � \.,, � 't DESCRIPTION HCA HC-2 CORNER OF STONE (1) 47.5' 17.3' CORNER OF STONE (2) 50.4' 28.8' CORNER OF STONE (3) 74.3' 38.1' CORNER OF STONE (4) 72.4' 30.4' i x19.6 , l x21.3 ,W ; ` � �. ALL ` '' •.., MAP 107 i �� , - - -� -- �,` � ' ''' . "' . , Cf27, LOT 5 12" EXI aTltvG i G 2-BEDR00*M1 DWELLING t HC-2 01 x21.1 ,� TOF=23.0'+ C!?At;'i_ FL. GARAG- .EL.=i0.6'± et x21.2 / V MAP 107 ��� ; t • . I LOT 6 o TP 1 62,090t S.F. k� J 1 t t PROPOSED TOTAL 20 o f �i ARC 36 (Model # 13) m- �•' PROP. ' ` ; ` 'F. OA/C AP' PL4STIC CHAMBERS I\J A 'J 6" D-BOX ` ^. 2 R0 FlE2 CONFIGURATt7N HC-1-> r 2 y:., 25.qE7h x21.6 ` 1) \3 1• :~ �b MAP 107 PROPOSED INSPECTION ORT WITH ACCESS LOT 7 L / " �`� BOX TO GRADE , - -22- 1-2 100 ) } r fi,r ' R=145.00 _30.00'� ~, z1_ ° 08' Y Y 6:':'. 'r ' 60.00' / ` t ` \ / /_\f S85° 08' 00"E L=9.59_.. G "--'' _t,%� ` •,, r--" GAS-- GAS Gt�SGAS �' r.--__-- • GkS rrc --"CAS . CAS r - CAS •�' �r _ ! - � .. , . _ '' " _r ! : , «! T .. i � "-r'._...,...,.. ,,, .. 20 .......a...._-. ,.. ,.. ,_.-..i - --• 7"� GE CyF�E't`�E�T E t k S.' ' •.J .. i y � .__.__'iry.•-t,"... -` ,. '-'.-r-.",. r-t^, r.e � �:'i<<, ii'' !'`_ .., ^1,._ ...-, - _, r_ ,p.-rI, e.-, '.`5''; t; ! �vtr WADSW ORTH LANE (40' WIDE LAYOUT) SITE PLAN SCALE: 1" =10' I -- ZONE 11v, LOCUS PLAN SCALE: 1" =1000' E\S1Gk! DATA NUMBER OF BEDROOMS (EXISTING) t 2� `2 NUMBER OF BEDROOMS (DESIGN) (��..3,� MIN. PER TITLE 5 DESIGN FLOW 110 GAL/DAYBEDROOM -� TOTAL DESIGN FLOW 330 i GAUDAY DESIGN FLOW x 200 % ��660 GAUDAY USE EXISTING (1,000 I GALiDNISEPTIC TANK \1/ INSTALL 20 ARC 36 PLASTIC CHAMBERS SYSTEM CAPACITY (TOTAL L.F. OF CHAMBERS) (4.8 SF/LF)f0.74 GPD/SQ.FT.) = GPD (100.0') (4.8 SF/LF) (0.74 GAUSQ.FT.) = 3� 5-5 2-\GAL. LEACHING / DAY TOTALS: TOTAL NUMBER OF CHAMBERS: 20 TOTAL LEACHING AREA: 480.0 TOTAL LEACHING CAPACITY: r 355.2 NOTE: EFFECTIVE LEACHING AREA OF 4.80 SFILF OBTAINED FROM THE DEPARTMENT OF ENVIRONMENTAL PROTECTION APPROVAL LETTER CERTIFICATION FOR GENERAL USE ISSUED TO INFILTRATOR SYSTEMS, INC., DATE OF REVISION: JUNE 12, 2015; TRANSMITTAL NUMBER = X264258. RESERVED FOR BOARD OF HEALTH USE THROUGH DiG-SAFE AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE AT 1-888-DIG-SAFE AND ANY OTHER APPLICABLE AGENCIES. REPORT ANY DISCREPANCIES TO THE DESIGN ENGINEER. 10. ALL JOINTS WHERE PIPE ENTERS AND EXITS CONC. STRUCTURES SHALL BE MADE WATERTIGHT. i 11. NO DETERMINTION HAS BEEN3_ AS TO COMPLIANCE WITH DEEDED E T 1 T D T A REGULAT O SA OWNER/APPLiCANTD S TO OBTAIN SUCH DETERMINATIONOFROMNING i i PERC NO. �t I)A __ APPROPRIATE AUTHORITY. I INSPECTOR: Barry Lewis (BOHj\ 12. ALL SEPTIC SYSTEM COMPONENTS SHALL WITHSTAND H-10 LOADING UNLESS LOCATED EVALUATOR: 'michael Pimentet, EIT, CSE i UNDER MORE THAN 3 FEET OF COVER OR LOCATED UNDER PAVEMENT, DRIVES, OR ' TRAVELED WAYS IN WHICH CASE THEY SHALL WITHSTAND H-20 LOADING. C.S.E. APPROVAL DATE Oct. 27, 1999 13 DOUBLE WASHED CRUSHED STONE SHALL BE FREE OF ALL DIRT, DUST AND FINES. DATE: June 6, 2024 TEST PIT #: 1 14. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL LOAM, SUBSOIL AND UNSUITABLE I MATERIAL IN AREA BENEATH AND FOR 5 FT. ON ALL SIDES OF LEACHING FACILITY. ELEV TOP = 21.50' REPLACE ALL UNSUITABLE MATERIAL WITH CLEAN COARSE SAND FREE FROM CLAY, FINES OR OTHER UNSUITABLE MATERIAL IN ACCORDANCE WITH 310 CMR 15.255(5). ELEV WATER = < 17.30' i 15. CONTRACTOR SHALL NOTIFY DESIGN ENGINEER OF ANY DISCREPANCIES FOUND IN PERC RATE _ < 2 min./inch SITE CONDITIONS FROM THOSE SHOWN PRIOR TO CONTINUATION OF WORK. DEPTH OF PERC = 3" - 21" 16. PROPOSED PROJECT IS LOCATED WITHIN: TEXTURAL CLASS: 1 ASSESSOR'S MAP 107 LOT 6 ( OWNER OF RECORD: KIM D. & MARY P. RAINERI 0" - 21.50' ADDRESS: 27 WADSWORTH LANE Fill 3" 21.25' Perc B 21 Med. to Fine Sand 19.75' 10Yr 5/6 30" 19.00, Fine Sand C 2.5Y 6/4_ 8 r. MOttlin �-4 84 50' @ _ C7 1 2° 6tandinq @a 102 `V i .00' 120" 1 ' 11.50, YARMOUTHPORT MA 02675 FEMA FLOOD ZONE X & X(<500) COMMUNITY PANEL# 25001CO579J 17. DEED REFERENCE: BOOK 13146, PAGE 241 18. PLAN REFERENCES: 1) P.B. 390, PG. 94 2) P.B. 381, PG. 91 3) P.B. 331, PG. 40 19. ALL DISTURBED AREAS SHALL BE RESTORED TO ORIGINAL CONDITION. 20. PROPERTY LINE INFORMATION IS ONLY APPROXIMATE. THIS PLAN IS TO BE USED ONLY FOR SEPTIC SYSTEM UPGRADE. JC ENGINEERING WILL NOT ASSUME ANY LIABILITY FOR USES OF THIS PLAN OTHER THAN iTS INTENDED PURPOSE. 21. OWNER / APPLICANT / CONTRACTOR SHALL BE RESPONSIBLE TO OBTAIN ANY AND ALL REQUIRED PERMITS AND APPROVALS FOR THIS PROJECT. 22. iN ACCORDANCE WiTH 310 CMR 15A01-15.405, THE FOLLOWING LOCAL UPGRADE APPROVAL IS REQUESTED FROM 310 CMR 15.212(1): 1.) A 1.0' WAIVER (5.0' - 4.0') FOR THE SEPARATION BETWEEN THE SAS AND ESHGW. 50x0' --- 50 - - - 50 CAS OIH I�%, -_ 9 i%1 i! I � Yarmouth IT-mna Dvert=enil: �D 1 9 L ECG ENO EXISTING SPOT GRADE EXISTING CONTOUR PROPOSED CONTOUR PROPOSED SPOT GRADE EXISTING GAS LINE EXISTING OVERHEAD UTILITIES JUL Q 2 2024 HEALTH DEPT. EXISTING WATER LINE EXISTING LANDSCAPED AREA TEST PIT LOCATION EXISTING 1,000 GALLON SEPTIC TANK PROPOSED 4" SOLID SCHEDULE 40 PVC PIPE PROPOSED DISTRIBUTION BOX PROPOSED ARC 36 PLASTIC CHAMBER REV. DATE TI BY APP'D. DESCRIPTION PROPOSED SEPTIC SYSTEM UPGRADE rEi, r: Mr, r d PREPARED FOR ROBERT B. OUR CO., INC. LOCATED AT 27 WADSWORTH LANE k ` " YARMOUTH, MA SCALE. 1 INCH = 10 FT. DATE: JUNE 28, 2024 ------ - ��a . 0 5 10 20 40 FEET .rc tN un t PREPARED BY CHURCH'' I JC ENGINEERING, INC. 2854 CRANBERRY HIGHWAY ' EAST WAREHAM, MA 02538 508.273.0377 Drawn By: MKV Designed By: MCP i Checked By: JLC 1 JOB No. 7829