HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M.__ Lot Zone of Contribution: In Out
Acreage
Street: Commercial:_ Residential:
Village: -----
Floor Plan:
Bedrooms:__
Owner:
Address: Installer:
Phone: Phone:
Builder:
Address: Engineer:
Phone: Phone:
1. Re.uired#of copies received a
2. Date of soils exam and .ercolation test not older than 2 years '
3. 4-5 ft of naturall occurrin• servious material, above water table
4.Foundation 2 ft above hi•h .oint of road
H.P.. Fnd: Var.: _5. Water line 10 ft from s-.tic com.onents
ar.:
6. Benchmark indicated and shown-NGVD if near wetlands I _
7. Seetic tank minimum 10 ft from foundation, deck Var.: _
8. Leachin. minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: _
9. Leachin. minimum 100 ft from wetlands _
410 Leachin• minimum 150 ft from drinkine well/25 ft irricati n well Var.: IMIIMINIIIIIIMIll
12 System meets a l'other setback f re uirements hne Var.:Var.:
111.1.1111111111
13. Uses ad-ustment for maximum hi h groundwater Var.: IIIIIIIIIIIIMMIIIIII
14. Leachincy set 4-5 ft above adf. water or bottom of test hole Var.:
15. System not in top or subsoil (A,B horizons)or 5' removal a
16. Pro.osed contours are suitable
17. System meets slope re.uirements-min. 1/8", V."preferred -IIIIIIIIII -
18. S stem meets breakout re•uirements �_
19. S.ecified tee sizes are .ro.er, oas baffle on outlet tee PVC liner: Wall: _�20. Sewaae is under 10,000 :,.d for .arcel __
21. No oazbage dis.osal IIIIMIMIIIIIIIIIIIII
22. System ade uately sized for its intended use -_
23. Minimum 6"stone or com.acted below tank and dbox S
24. Manhole covers within 6"of grade, sump chamber cover to grade S-
25. Ins section sort on elastic chambers/leach field111111111.1111111
26. Electrical .erm m
it for .u . chamber/Se.arate meter for du.lexes IIIIIIII-
27.Puma s stem-2"line,wee. hole,check valve, tee in dbox, I,um. size __
28. Se.tic tank/.um. chamber to be factory wate .roofed
29. Vent .rovided if leachin below 3 feet,under driveway/parkin° _IIIIIIIIIIIIIIIIIII
30. Buo anc calculations for-tank/sums chamber
31. En:'neer to ins sect and certi S
32. En:'neer/Re:istered Sanitarian and Land Survesor stam.s/siwgnature commercial: --
33.H-20 loading is sub-ect to vehicular traffic, : oundwater IIIIIIIIIIIII_--
34.Title V Ape lication and .ermit fee, installer si• .ature -
35.Foundation footing min. 2 feet above ad'usted around water for new house --
36.Deed Restriction re.uired max. #bedrooms: niax. flow: 1.d
37. Check area lots for groundwater/Label groundwater in Assessor's Ma.
Plan reviewed by: