Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M.__ Lot Zone of Contribution: In Out Acreage Street: Commercial:_ Residential: Village: ----- Floor Plan: Bedrooms:__ Owner: Address: Installer: Phone: Phone: Builder: Address: Engineer: Phone: Phone: 1. Re.uired#of copies received a 2. Date of soils exam and .ercolation test not older than 2 years ' 3. 4-5 ft of naturall occurrin• servious material, above water table 4.Foundation 2 ft above hi•h .oint of road H.P.. Fnd: Var.: _5. Water line 10 ft from s-.tic com.onents ar.: 6. Benchmark indicated and shown-NGVD if near wetlands I _ 7. Seetic tank minimum 10 ft from foundation, deck Var.: _ 8. Leachin. minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: _ 9. Leachin. minimum 100 ft from wetlands _ 410 Leachin• minimum 150 ft from drinkine well/25 ft irricati n well Var.: IMIIMINIIIIIIMIll 12 System meets a l'other setback f re uirements hne Var.:Var.: 111.1.1111111111 13. Uses ad-ustment for maximum hi h groundwater Var.: IIIIIIIIIIIIMMIIIIII 14. Leachincy set 4-5 ft above adf. water or bottom of test hole Var.: 15. System not in top or subsoil (A,B horizons)or 5' removal a 16. Pro.osed contours are suitable 17. System meets slope re.uirements-min. 1/8", V."preferred -IIIIIIIIII - 18. S stem meets breakout re•uirements �_ 19. S.ecified tee sizes are .ro.er, oas baffle on outlet tee PVC liner: Wall: _�20. Sewaae is under 10,000 :,.d for .arcel __ 21. No oazbage dis.osal IIIIMIMIIIIIIIIIIIII 22. System ade uately sized for its intended use -_ 23. Minimum 6"stone or com.acted below tank and dbox S 24. Manhole covers within 6"of grade, sump chamber cover to grade S- 25. Ins section sort on elastic chambers/leach field111111111.1111111 26. Electrical .erm m it for .u . chamber/Se.arate meter for du.lexes IIIIIIII- 27.Puma s stem-2"line,wee. hole,check valve, tee in dbox, I,um. size __ 28. Se.tic tank/.um. chamber to be factory wate .roofed 29. Vent .rovided if leachin below 3 feet,under driveway/parkin° _IIIIIIIIIIIIIIIIIII 30. Buo anc calculations for-tank/sums chamber 31. En:'neer to ins sect and certi S 32. En:'neer/Re:istered Sanitarian and Land Survesor stam.s/siwgnature commercial: -- 33.H-20 loading is sub-ect to vehicular traffic, : oundwater IIIIIIIIIIIII_-- 34.Title V Ape lication and .ermit fee, installer si• .ature - 35.Foundation footing min. 2 feet above ad'usted around water for new house -- 36.Deed Restriction re.uired max. #bedrooms: niax. flow: 1.d 37. Check area lots for groundwater/Label groundwater in Assessor's Ma. Plan reviewed by: