Loading...
HomeMy WebLinkAboutEngineer PlanLEGEND --- 99 - EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. ---[99] -- PROPOSED CONTOUR 198.4] PROPOSED SPOT EL. TH1 0 TEST HOLE 20/.- SLOPE OF GROUND C71) UTILITY POLE FIRE HYDRANT NOTE NOT ALL SYMBOLS MAY APPEAR IN DRAWING DC'E #24-135 SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED EXISTING 3 BEDROOM DWELLING DESIGN FLOW: 3 BEDROOMS ® 110 GPD = 330 GPD USE A 330 GPD DESIGN FLOW SEPTIC TANK: 330 GPD (2) = 660 **RE -USE EXISTING 1000 GAL. SEPTIC TANK LEACHING: 330 GPD (.74) = 446 SF REQUIRED 10' X 45' = 450 SF OK 450 SF X .74 = 333 GPD OK USE A 10' X 45' PIPE AND STONE LEACHING FIELD 5' REMOVAL OF UNSUITABLE SOIL REQUIRED AROUND PERIMETER OF LEACHING FACILITY, DOWN TO SUITABLE SOIL LAYER. REPLACE WITH CLEAN MED. SAND, TO MEET SPECIFICATIONS OF 310 CMR 15.255(3) SYSTEM PROFILE (NOT TO SCALE) 29.3' MINIMUM .75' OF COVER OVER PRECAST 2% SLOPE REQUIRED OVER SYSTEM 28,28' U low NG 14" TEE SEPTIC TANK** TEE ZABEL FILTER (A10O) OUTLET TEE W/EXTENSI **INSTALLER SHALL CONFIRM MINIMUM SEPTIC TANK SIZE AT 1000 GALLONS AND ITS SUITABILITY FOR RE -USE. REPLACE WITH 1500 GALLON SEPTIC TANK APPROPRIATE TO SITE CONDITIONS IF NOT SUITABLE FOUNDATION EXIST. SEPTIC TANK *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM .95' 4-OSCH40 PVC PIPES LEVEL 1ST 2' C C WATERTEST D'BOX °°o FOR LEVELNESS 26.58' 6.41' 26' 6" CRUSHED `;TONE OR MECHANICAL COMPACTION. (15.221 [21) MARK CORNERS OF LEACHING FIELD W/ REBAR SET 4" BELOW INSPECTION PORT GRADE 2% SLOPE FILTER FABRIC TOP 26.66 FINISHED GRADE- REPLACE EXISTING GRAVEL DRIVE 28.®' CLEAN FILL DOUBLE4" PERFORATED PVC 4! O.C. S=0.005 6"DEPTH MIN • :STONE LEACHING FIELD• LEVEL BOTTOM (_IJ% SLOPE) (_1% SLOPE) 20' D' BOX 8' LEACHING FACILITY VARIANCES REQUESTED: UNDER MAX. FEASIBLE: COMPLIANCE 15.405: (lb): REDUCTION IN SETBACK, SAS TO FOUNDATION (20' TO 18.9') (1h): REDUCTION IN SEPARATION TO G-W (5' TO 4') FA i Li` ROOM KITCHEN LIVING ROOM DINING ROOM BATH I BED ROOM IROOM .�� : E D 'O• 45.0' 25.60' 4.00' ---� ADJUSTED GROUNDWATER EL. 21.6' NOTES 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-I( 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE -RESPONSIBLE FOR CALLING DIGSAFE (811) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED BENEATH AND 5' AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. 13. OWNER'S ENGINEER TO PERFORM INSPECTIONS OF THE FINAL INSTALLATION. MINIMUM OF 24 HOURS NOTICE REQUIRED. 14. EXISTING 1000 GAL. SEPTIC TANK TO REMAIN :ie111 Dopa- rilli',ilt Higgins Crowell Road �o Coyly Electric � Locus o�ytobP�tQ°�� fib. 0 � Jar Q E'nginehouse Rd. ,��, l's s%ate a a LOCUS MAP SCALE 1 "=2000'f ASSESSORS MAP 63 PARCEL 6 LOCUS IS WITHIN FEMA FLOOD ZONE X (AREA OF MINIMAL FLOOD HAZARD) AS SHOWN ON COMMUNITY PANEL #25001CO567J DATED 7/16/2014 SITE IS WITHIN STATE DESIGNATED NSA TEST HOLE LOGS ENGINEER: DANIEL E. GONSALVES, SE #13587 WITNESS: BARRY LEWIS DATE: 6/6/2024 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS ELEV. 28.0' A LS 10YR 3/2 691 B LS 1OYR 5/6� 26" / / / / 25.8' C1 M/CS ® UNSUITABLE SOIL 2.5Y 6/4 VEA D G-W ADJ. DATA: 1�.,� WELL: Al W--231 i�i�q.i Date ZONE: E ADJ: 2.1' MAY 2024 120" 18.0' GROUNDWATER ENCOUNTERED AT 102" EL. 19.5 U I T L EmEm 5 S I TEmm L A 3! PREPARED FOR �SNOFMgs DANIELsgc �FMr BORTOLOTTI COPNOSTRUOO"'6TIO C A. ti� a� F'%. in�' .o` DANIEL oyG :�I'.'IL N oc A. CLAD O'BRIENI N,) 46502 � " OJALA cm 0 P `c��O��� �No.40980 k1�G�STEo S;S�10�NAL ENG r° 1FFss�o`' RECEIVED DUNE 13, 2024 Y� V. v sNO SU- JUL 1 1 2024 Scale:1 "= 20' HEALTH DEPT. -- Fs,j��j� 0r Mf Ssq� 0 10 20 30 40 50 FEET �✓ C, !�� CAN,11. -L .Tv DAMEL A. osr{� rs �o OJALA . ` i v t: [o CIVIL �� <�� off 508-362-4541 t No. 65p2 �� Jf fax 508-362-9880 �o F �o downcape.com SS'IpIVAL �bJ ti� a{,� yl� ♦ ♦ - OWN CQ a ell ,fieero17 ,14C. �• (�"� .r-\ ci vi/ engineers land surveyors 939 Main Street ( Rte 6A) SURVEY: NHO DATE DANIEL A. OJALA, P.E., P.L.S. YARMOUTHPORT MA 02575 DRAFTED BY: PTT CHECKED 8Y: 24-135 BORTOLOTT-OBRIEN-CLARK.DWG