Loading...
HomeMy WebLinkAboutEngineer Plan1 LEGEND 99 — EXISTING CONTOUR X 99• EXIST. SPOT ELEV. —[99)-- PROPOSED CONTOUR 198.41 PROPOSED SPOT EL. TH1 �2�21tea TEST HOLE SLOPE OF GROUND rob UTILITY POLE y FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM �32- O IN 1331 5,1133 ^ I ^, u ZONING SUMMARY ZONING DISTRICT: R-40 DISTRICT MIN. LOT SIZE 40,000 S.F. ° MIN. LOT FRONTAGE 150' MIN. FRONT SETBACK 30' MIN. SIDE SETBACK 20' MIN. REAR SETBACK 20' 4- MAX. BUILDING COVERAGE 25% tti9 MAX. BUILDING HEIGHT 35' N ° a Ln w / DWELLII TOF = SYSTEM DESIGN: j ��°� c29 GARBAGE DISPOSER IS NOT ALLOWED ` `L� PROPOSED GARA SLAB 29.3 PROPOSED 5 BEDROOM DWELLING / 26 DESIGN FLOW: 5 BEDROOMS @ 110 GPD = 550 GPD USE A 550 GPD DESIGN FLOW 29] a SEPTIC TANK: 550 GPD (2) = 1100 Q D USE A 1500 GAL. SEPTIC TANK LEACHING: .411 SIDES: 2 (42 + 12.83) 2 (.74) = 162 GPD �251 BOTTOM 42 x 12.83 (.74) = 398 GPD 85'43'17"E TOTAL: 756 S.F. 560 GPD 151.00 USE (4) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE ALL AROUND MA r APPROVED DATE BOARD OF HEALTH Vermouth Heaith Department Date SYSTEMSYSTEM PROFILE MMMAARKED WITHCMAGNETIIC TAPE O BE (NOT TO SCALE) COMPARABLE MEANS FOR FUTURE LOCATION. ACCESS COVERS TO WITHIN 6" OF FIN. GRADE 2' PEASTONE OR GEOTEXTILE CONCRETE COVERS TO WITHIN 3" GRADE \--f TOP FOUND. EL. 29.7' FILTER FABRIC OVER STONE 28.0' MINIMUM .75' OF COVER OVER PRECAST 2X SLOPE REQUIRED OVER SYSTEM 26-27' BLOCKS OR / PRECAST M-10 WATERTEST D'BOX FOR LEVELNESS PRECAST RISERS ,5 INVERT IN 23.20' / RISERS (TYP.) 4"0SCH40 PVC MORTAR ALL , . ` ', PIPES LEVEL 1ST 2' 4' iNP•) 4 ENDS SIDES 24.03 L;.. ,. o 25.7' 10* 1500 GAL H-10 14" ' ,•000�a�..•;•• .:. , ...:.,:. :. r. +... TEE SEPTIC TANK TEE ® ® ®�® ® ®-- ®� '°°°°°°°° ;.; 25.23' 4.98 °g°g°o° '• OOOQOOOOQOOO ®� :°°°�° .. . GAS BAFFLE o 0 0 0 ° o >°°°°°°°°IMP °pop ° ° ° a 4' uQ. LEVEL (ACME oR EQUAL) .; 23.54' .37' '> �o�o�o�0 21.20' ... J0° 000000000000000000°000ao�oQQoo°00000000O4 o;°�°oor°o,°,o,°,o°,o°,000000000�o�°o�o�°,o�,o�,o;00000P 3/4 "-1=1 2" DOUBLE WASHED STONE 4' MIN.�H-10 500 GAL. LEACHING CHAMBERS BY ACME PRECAST OR EQUAL ALL AROUND PRECAST STRUCTURES (4) UNITS REQUIRED 6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 42.00' X 12.83' COMPACTION. (15.221 [2]) �! i 2.5 w e, non f 2 Y ci narl w si npr) NOTES 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS PROPSOED 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASAO H—M 5. PIPE J014TS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10 CONTRACTOR SHALL BE RESPONSIBLE FOR CAWNG DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCUS MAP LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. SCALE 1 "=2000'f 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED BENEATH AND 5' AROUND THE PROPOSED ASSESSORS MAP 122 PARCEL 24.1 LEACHING FACILITY. TEST HOLE LOGS ENGINEER: DANIEL A. OJALA, P.E., P.L.S. WITNESS: AMY VON HONE, RS DATE: 7/13/2017 PERC. RATE _ < 2 MIN/INCH CLASS i SOILS ELEV. ELEV. 0" 28' 0" 27' A A LS LS 10YR 4/2 10YR 4/2 1011 12„ B B LS LS .28" 10YR 5/4 ' 25.734 10YR 5 4 / 24.2 C C PERC MS MS 10YR 6/6 10YR 6/6 120„ 18' 132" 16' NO GROUNDWATER ENCOUNTERED 'mum m 0 m T I T LE P 0 A N OF #63 THACHER.SHORE ROAD YAR" ®UT P®RT' / i VI PREPARED FOR BRIAN BASLER a `DATE: SEPTEMBER 27, 2022 REV.: OCTOBER 18, 2023 REV.: DECEMBER 19, 2023��- Scale: 1"= 20' �qM QF hfq 4 DANIEL GN JuN Q L ti DANIELA. 10, OJALA Sni 0 10 20 30 40 50 FEET HEALTH, I. �o OJALA No. 40980 CIVIL cn,� �oF�ss\o�'P off 508-362-4541 �No. 46502o w�� �qNO EM fax 508-362-9880 o3UR� � Ff� / " " I downcope.com civil engineers fond surveyors 939 Main Street ( Rte 6A) DATE DANIEL A. OJALA, P.E., P.L.S. YARMOUTHPORT MA 02675 17-324