HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. Lot 3 y 4/6.( Zone of Contribution: In Out ----Acreage �,,Q Commercial: Residential: . - Street: 3 (4/9 b 4� ✓� #Bedrooms: 4 Village: IN /� Floor Plan: // Owner: o h r 064 V i j 5 Installer: 54- , / i. Address: 3c 2 Z i sj u L1 Phone: S-b -3 b(...)-- ,v Phone: 7•/_ Esz--gy b 8-- Builder: Engineer: 5 6.\. �i'l l>>f Oy+1.Q,r4( Address: Phone: cb & „5'/- 74/5 fr Phone: N/A YES NO 1.Required#of copies received EZ 2.Date of soils exam and percolation test not older than 2 years 3.4-5 ft of naturally occurring pervious material,above water table ✓ 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: ✓ 5.Water line 10 ft from septic components Var.: V 6. Benchmark indicated and shown-NGVD if near wetlands V 7. Septic tank minimum 10 ft from foundation,deck Var.: v 8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: V 9.Leaching minimum 100 ft from wetlands Var.: v 10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: v 11.Tank/leaching minimum 10 ft from property line Var.: ✓ 12. System meets all other setback requirements Var.: 13.Uses adjustment for maximum high groundwater Var.: ✓ 14. Leaching set 4-5 ft above adj.water or bottom of test hole Var.: S' - 'r 15. System not in top or subsoil(A,B horizons)or 5' removal 16.Proposed contours are suitable ✓ 17. System meets slope requirements-min. 1/8", '/"preferred v 18. System meets breakout requirements PVC liner: Wall: v 19. Specified tee sizes are proper,gas baffle on outlet tee ✓ 20. Sewage is under 10,000 gpd for parcel V 21.No garbage disposal t/ 22. System adequately sized for its intended use V 23. Minimum 6"stone or compacted below tank and dbox ✓ 24. Manhole covers within 6"of grade,pump chamber cover to grade ✓ 25. Inspection port on plastic chambers/leach field ,/ 26. Electrical permit for pump chamber/Separate meter for duplexes ✓ 27. Pump system-2"line,weep hole,check valve,tee in dbox,pump size ✓ 28. Septic tank/pump chamber to be factory waterproofed / 29.Vent provided if leaching below 3 feet,under driveway/parking i/ 30.Buoyancy calculations for tank/pump chamber 31.Engineer to inspect and certify soils: wall: commercial: V 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature _V 33. H-20loading is subject to vehicular traffic, groundwater / 34. Title V Application and permit fee,installer signature ✓ 35.Foundation footing min. 2 feet above adjusted ground water for new house ✓ 36.Deed Restriction required max. #bedrooms: ow: gpd ✓ ✓ 37. Check area lots for groundwater/Label groundw 'n se s Map Plan reviewed by: 6-6�c( 6/03/03