HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. Lot 3 y 4/6.( Zone of Contribution: In Out ----Acreage
�,,Q Commercial: Residential: . -
Street: 3 (4/9 b 4�
✓� #Bedrooms: 4
Village: IN
/� Floor Plan: //
Owner: o h r 064 V i j 5 Installer: 54- , / i.
Address: 3c 2 Z i sj u L1 Phone: S-b -3 b(...)-- ,v
Phone: 7•/_ Esz--gy b 8--
Builder: Engineer: 5 6.\. �i'l l>>f Oy+1.Q,r4(
Address: Phone: cb & „5'/- 74/5 fr
Phone:
N/A YES NO
1.Required#of copies received
EZ
2.Date of soils exam and percolation test not older than 2 years
3.4-5 ft of naturally occurring pervious material,above water table ✓
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: ✓
5.Water line 10 ft from septic components Var.: V
6. Benchmark indicated and shown-NGVD if near wetlands V
7. Septic tank minimum 10 ft from foundation,deck Var.: v
8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: V
9.Leaching minimum 100 ft from wetlands Var.: v
10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: v
11.Tank/leaching minimum 10 ft from property line Var.: ✓
12. System meets all other setback requirements Var.:
13.Uses adjustment for maximum high groundwater Var.: ✓
14. Leaching set 4-5 ft above adj.water or bottom of test hole Var.: S' - 'r
15. System not in top or subsoil(A,B horizons)or 5' removal
16.Proposed contours are suitable ✓
17. System meets slope requirements-min. 1/8", '/"preferred v
18. System meets breakout requirements PVC liner: Wall: v
19. Specified tee sizes are proper,gas baffle on outlet tee ✓
20. Sewage is under 10,000 gpd for parcel V
21.No garbage disposal t/
22. System adequately sized for its intended use V
23. Minimum 6"stone or compacted below tank and dbox ✓
24. Manhole covers within 6"of grade,pump chamber cover to grade ✓
25. Inspection port on plastic chambers/leach field ,/
26. Electrical permit for pump chamber/Separate meter for duplexes ✓
27. Pump system-2"line,weep hole,check valve,tee in dbox,pump size ✓
28. Septic tank/pump chamber to be factory waterproofed /
29.Vent provided if leaching below 3 feet,under driveway/parking i/
30.Buoyancy calculations for tank/pump chamber
31.Engineer to inspect and certify soils: wall: commercial: V
32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature _V
33. H-20loading is subject to vehicular traffic, groundwater /
34. Title V Application and permit fee,installer signature ✓
35.Foundation footing min. 2 feet above adjusted ground water for new house ✓
36.Deed Restriction required max. #bedrooms: ow: gpd ✓ ✓
37. Check area lots for groundwater/Label groundw 'n se s Map
Plan reviewed by: 6-6�c( 6/03/03