Loading...
HomeMy WebLinkAboutSight Plan �i� j (j �j j� / v...v �R r 3(—WO" T L+� L5 II L'! LL, ' ae[ce*'wde gV "-sr •4,6-z --!/, PAitT of 7 • A = o,ZB�c � 11 SEP 2 001 - N ti By .r °a • 10 Op a b\ CONCRETE a• FOUNDATION • .$ • 0%.c30 • (20* 9 1 % LOTS 67 et68 <A�'� "� 44° 12086 ± S.F. 5 ®:\' • N,O$ 1 i 4 • • i • i TOWN OF YARMOUTH ZONING III o a CV Ill ZONE : RC ; •--- z SETBACKS : ,,, • ,,a It I ,' J REAR - 20' fr- FRANK..r , g Imm THE DWELLING DEPICTED ON THIS 1 Na 29869 . PLAN WAS LOCATED ON THE GROUND *41Cm ° PLOT PLAN BY SURVEY ON AUG. 21. 2001 0 Bq1 „a" A �1i / IN AND EXISTS AS SHOWN AS OF THE DATE OF LOCATION. 9/2.� 00 P YARMOUTH. MA. THIS PLAN IS FOR PLOT PLAN SCALE: 1'-4D' SEPT. 7. 2001 PURPOSES ONLY AND NOT FOR REVISED SEPT. 24. YODI RECORDING. DEED DESCRIPTIONS EAGLE SURVEYING, I NC 023 wwt• OA OR ESTABLISHING PROPERTY LINES. .�'7 . �F vn•.etkr•.t, M. enr�s ., r caw) ass-span `/ , (a00) 432•4333 THIS PLAN 1S VOID IF NOT -. _ • STAMPED AND SIGNED IN RED. 0 20 40 80 PROJECT ND. OI-OBI 1 • D+Girit6v «r GAS 3l4l02. SECTION A -A VENT PIPE 0 Least 24 Inches toll) PROFILE VIEW OF LEACHING SYSTEM 10' min. from 'NOTE: ALL PIPES ARE TO BE 4" SCHEDULE 40 P.V.C. Schedule 40 PVC w/Charcoci Odor Filter SAS cover must be LXISTING Foundation house to septic tank within 6" of GRADE Septic tank covers must be �D—BOX cover must must have riser and be ti within 6 in. of finished grade within 6 in. of finished grade b f 1/2 " we"Ms Coen" seo"e • ef W — r/s" ►omed pembwe —Grade over Septic Tank — 99.00 Grade over D—Box — 99.00 Okada over SAS —99.00 to 100.00 INSPECTION cover must be within 6 in. of finished grade S 0.02 Tee to be placed in dbox 3 HOLE 10 DIST BOX TOP OF SAS — 96.00 r3 M r3 o o O 15' 5=0.01 S-0.01 A C3 0 r3 C3 C3 o c EXIsr. PIPE N EXIST 1,000 GAL t RON FOUNDATION W SEPTIC TANK ss' M ,n 15' 11 H-10 oa. e.ro.r• � .► 04.4w sr" r .w "Raw vi ui j�9_7 000NCRETE FULL FOUNDA rn4 lAhIts 6 SYSTEM PROFILE v 8 z' z4' z' I _� s PROVIDED Not to Scale — 4' '�-8 c c 4, I Effectl28 Length 6 in.of 3/4'-1 1/2• f %' i; compacted stone Effective Width To SOIL ABSORPTION SYSTEM <SAS) m° LC-6 H-20 LEACHING UNITS / WIGGINS PRECAST NOTE: ALL COMPONENTS MUST HAVE RISERS TO WITHIN 6' BELOW GRADE Bottom of Test Hole 1 Elev.- 88.00 0 TP1 Not to Scale DIAM. ACCESS MANHOLES STEEL REINFORCED PRECAST CONCRETE PLAN VIEW 3-24' REMOVABLE COVERS I PERCOLATION TEST H —10 Date of Percolation Test:MAY 2, 2024 Test Performed By. CARMEN SHAY, C.S.E. Results Witnessed By. YARMOUTH BOH -BARRY LEWIS EXCAVATOR: SHAY ENVIRONMENTAL SERVICES Percolation Rate: Less Than 2 MPI 0 30" THE ACCESS COVERS FOR THE SEPTIC TANK, DISTRIBUTION BOX AND LEACHING COMPONENT SET DEEPER THAN 6 INCHES BELOW FINISHED GRADE SHALL BE RAISED TO WITHIN 6' OF FINISHED GRADE. INSTALL TUF—nTE GAS BAFFLES OR EQUALS 3" min. clearance e" m��2_ min. inlet to outlet e' min. Uqu1d 'everOUTUET 10' min. ,. ie, s -T• 5' —T" 1: E $ ' 4 —0' mim b e» ee,e. Liquid depth tv_ 10'-0' 4' —10"— CROSS SECTION END -SECTION TYPICAL 1500 GALLON SEPTIC TANK Design C41CUIat10r1S Number of Bedrooms: 4 Equivalent to 440 Gol./Day 9 Garbage Grinder: No Leaching Capacity Proposed: 440 Gal./Day Minimum Septic Tank : - 2 x 440 Got./boy = 880 USE EXIST. 1,500 GAL. Septic Tank. SOIL ABSORPTION AREA: Using percolation rate of <2 min./inch Bottom Area: 0.74 gal/day/sq. ft. x 407 sq. ft. = 301,18 gallons/day Sidewall Area: 0.74 gal./day/sq. ft. x 192 sq. ft. = 142.08 gallon/day Providing:=443.26 gallons/day Use: (5) LC-6 H-20 CONCRETE CHAMBERS, HAVING A 1' EFFECTIVE DEPTH, (3' W x 6' L) TO BE USED WITH 4' OF WASHED STONE ON THE SIDES AND 3.5' OF WASHED STONE ON THE ENDS AND 1 FOOT OF STONE UNDER ENTIRE SAS . Test Hole No. 1 DEPTH SOILS ELEV. 0 99.50 Loamy Sand 10 YR 3/2 A„ P. Loamy 10 YR 6"— 30" Bw Med—Coc 2SYT 30"- 126 s 9valid for REPAIR OF SEPTIC due to State and Local septic YSTEM ariances. dI.Y, J3 artr Ilealth re%iew and approval is re uired for a y f ture additions/renovations/'altera iO0 rio se acilities and/or structures/dwelling. Yarmouth Health Department r e APPROVED s.Da XG ry rte Dat Perc #1 Depth to Perc 30" to 48" Perc Rate= <2 MPI Groundwater Not Observed No Observed ESHWT 0 126" ADJUSTED H2O Elev. = None 0 126" 0 TP1 DISTRIBUTION BOX SHALL BE SET LEVEL FOR AT LEAST 2 FT. 12 CONCRETE COVER !� •. : i ...•T'.. Y•�(.l.s :fie 3 — S' OUTLET •.. KNOCKOUTS 1ss• t , OUTLET i 1 12' INLET s• a 1S5' 4' — SCH. 40 Te 1.73' PLAN SECTION CROSS—SECTION 3 HOLE H-10 DISTRIBUTION BOX PLOT PLAN PROPOSED SEPTIC SYSTEM UPGRADE PREPARED FOR ESTATE OF JOHN DAVIDSON AT 35 MARIGOLD ROAD PARCEL ID: 37/116.1 SOUTH YARMOUTH ��N,g/SIIAY ENVIR0.1WENTAL SERVICES U 201 PLUM HOLLOW ROAD EAST FAL:LMOUTH, MA 02536 TEL/FAX : 508-294-7498 SCALE: 1 "=20' DRAWN BY: CES DATE: MAY 15, 2024 PROJECT#35 MARIGOLD FILENAME: 35 MARIGOLD.DWG SHEET 2 OF 2