Loading...
HomeMy WebLinkAboutEngineer Plan1 1 3 TEST HOLE # 1 ELEV.= 99.50 LOTS #67 & 68 12,086 Square Feet t/- PROJECT BENCH MARK TOP OF FOUNDATION ELEV. = 100.00 ASSUMED T,T N 46D 39' 50" E VENT 150.00' PIPE FAILED� / .1 LEACF' PIT 0 150.00, S 46D 39' 50" W � DECK SLAB FND. COVERED DECK GRAVEL DRIVEWAY .M:ARIGO-El? (40 FOOT RIGHT OF WAY) C0 1500 GALLON O SEPTIC TANKI(EXIST.) 3 Season Room J6, EXISTING 4 BEDROOM HOUSE #35 8 FULL FOUNDATION vv C+o � w- N z to c � F 35 Marigold Road, West Y... X g ood at V:4' H;" lrisR a .S Heavenly !' Sunbird Cape Cod R _ Lc" 3 d t i61) 3-star hctel ? Gar( *:ys de Resort a . t z • (C"A) '4-�i.,� Live 35 Marigold Rd Permit valid for REPAIR OF SEPT C SYSTEM h' OA-D ONLY, due to State an(t Local septic variances. Board of Health review and approval is required for any future addition sireno%ations/aIterations to sewage facilities and/or structures/dwelling. VARIANCE REQUESTED: 1. VARIANCE REQUESTED TO HAVE 4 FEET OF COVER OVER AN SAS A VENT PIPE HAS BEEN PROVIDED 0 20 40 50 SCALE: 1 "=20' Name Yarmouth Health Department APPROVED GENERAL NOTES 1. Contractor is responsible for Digsofe notification, Verification of Utilities and protection of all underground utilities and pipes. 2. The septic tank on j distribution box shalt be set level on 6 of 3/4 —1 1 /2" stone. 3. Backfill should be clean sand or gravel with no stones over 3" in size. 4. This system is subject to inspection during installation by Carmen E. Shay — Environmental Services, Inc. 5. The contractor shall install this system in accordance with Title V of the Massachusetts state code, the approved plan and Local Regulations. 6. If, during installation the contractor encounters any soil conditions or site conditions that are different from those shown on the soil log or in our design installation must halt & immediate notification be made to Carmen E. Shay — Environmental Services, Inc. 7. No vehicle or heavy machinery shall drive over the septic system unless noted as H-20 septic components. 8. Install Tuf—rite gas baffles or equals on all outlet tee ends. 9. All Distribution Lines shall be 4" diameter Schedule 40 NSF PVC pipes. 10. All solid piping, tees & fittings shall be 4" diameter Schedule 40 NSF PVC pipes with water tight joints. 11. Municipal Water is Connected to ALL OF The Residence and Abutting THE PROPERTY LINES ARE APPROXIMATE AND COMPILED FROM THE SURVEY PLAN BY EAGLE SURVEYING YARMOUTH, MA ENTITLED: "CERTIFIED PLOT PLAN-35 MARIGOLD ROAD, S. YARMOUTH, MA" DATED: SEPT. 7, 2001 AND IS NOT INTENDED TO BE A SURVEY PLOT PLAN IT SHOULD BE USED FOR NO PURPOSE OTHER THAN THE SEPTIC SYSTEM INSTALLATION. EXISTING LEACH PIT TO BE PUMPED OUT AND FILLED IN PLACE NOTE: ANY STRIPPED OUT SOIL CONTAINING LEACHATE FROM THE EXISTING CESSPOOL/LEACH PIT TO BE DISPOSED OF AS PER BOARD OF HEALTH SPECIFICATIONS. PLOT PLAN OF PROPOSED SEPTIC SYSTEM UPGRADE PREPARED FOR ESTATE OF JOHN DAVIDSON r a c,, w t�h `� J � AT 35 MARIGOLD ROAD PARCEL ID: 37/116.1 SOUTH YARMOUTH PREPARED BY: -HAY ENVIR0NME-1VTAL SERVICES 281 PLUM HOLLOW ROAD EAST FAL:LMOUTH, MA 02536 TEL/FAX : 508-294-7498 SCALE: 1 "=20' DRAWN BY: CES DATE: MAY 15, 2024 PROJECT#35 MARIGOLD FILENAME: 35 MARIGOLD.DWG SHEET 1 OF 2