HomeMy WebLinkAboutEngineer PlanFINISHED GRADE @ FOUNDATION = 14.4'± PROP. SCH. 40 PVC SEWER 8't MIN. SLOPE (a� FINISH GRADE OVER D-BOX = 15.3't REMOVABLE WATER -TIGHT COVER OVER RISER TO WITHIN 6" OF FINISHED GRADE 5" DIA. OUTLET(S) 9" MIN. 36 MAX. L=131 t PROVIDE WATERTIGHT 4" PVC IN FROM JOINTS (TYP.) I SEPTIC TANK 4" PVC OUT TO 0 LEACHING FACILITY 12" 6" 12.50'-J 48" `-OUTLET TEE 12.10, MIN. 11. 3' TEES TO BE CENTERED GAS BAFFLE 6" CRUSHED STONE DIRECTLY UNDER RISERS OVER MECHANICALLY 13.2' OFFSET TO FND COMPACTED BASE 6" CRUSHED STONE 5 OUTLET DISTRIBUTION BOX OVER MECHANICALLY TO BE INSTALLED ON A LEVEL STABLE COMPACTED BASE BASE. FIRST TWO FEET OF OUTLET PROPOSED 1,500 GALLON CONCRETE SEPTIC TANK PIPES TO BE LAID LEVEL. T0 t,171 Y ..7T• ",, . LENGTH 10'-6' WIDTH 5'-8" DEPTH 5'-8" (Dimensions per CROSS p SECTION VIEW SEPTIC- PROFILE ACME/Shorey) DST(�®%U_tOl EO DETAIL F "': TaI 1` 17N.r <§"_> ", I D:r L`' NOT TO SCALE NOT TO SCALE #10 SWING -TIES .'� EXISTING 2-BEDROOM F.G. OVER TANK EL.=14.6' - 15.0' 9" MIN. 36" MAX. /-PROP. SCH. 40 PVC SEWER 6" 3" 2�� DROP MIN. :13-1 3" DROP MAX. 3„9 14" INLET TEE DESCRIPTION HC BC TANK COVER IN (1) 39.0' 17.2' TANK COVER OUT (2) 37.4' 21.1' CORNER OF STONE (3) 43.1' 28.6' CORNER OF STONE (4) 34.7' 37.8' CORNER OF STONE (5) 25.5' 31.5' CORNER OF STONE (6) 27.2' 40.7' CORNER OF STONE (7) 46.6' 53.4' CORNER OF STONE (8) 52.3' 39.6' -PROPOSED EXTENSION RISER WITH COVER OVER INLET & OUTLET TO WITHIN 6" OF F.G. 21" MIN. ACCESS COVER (TYP.)-\ \-12.25' ` DWELLING N I Yi % (FULL BASEMEI OQ� i OJT MAP 23 LOT 79 i 3' GL �0 r\vN1 057 BUSH v QpJ ; C (TYP) `�°o till � MAP 23 EXISTING LEACHING U.P.t1 CATCH -BASIN (TYP. OF 2) LOT 80 \ \ 7 9,600t S.F.-7 9 00 j �\\ \BOO \� EXISTING Benchmark 14 \ \ 2-BEDROOM Bulkhead Comer r 0 UI Clf'•UnMf 11 C AA rllfr% t V./ \/ sr DIMENSIONS SCALE: 1" = 20' FINISH GRADE OVER CHAMBERS = 14.6' - 15.3' SLOPE @ 2% MIN. OVER SYSTEM \-5' MIN CHAMBER DE T AILS NOT TO SCALE EXISTING SHED TO I 1 BE REMOVED AT TIME OF UTILIZING RESERVE AREA RESERVE AREA CAPACITY = 472 GPD Elev. = 14.84' O / DWELLING \ :.._, (FULL BASEMENT) \1 N.A.V.D. 88 �I,r41 i PROPOSED 1,500 GALLON ���` .�, : �,�' 13„ , =t SEPTIC TANK -f 00 MAP 23- LOT 81 j �t cgs ,�. 1) i� \ \ \, \ HC e PATIO% A�� /os' 121 SHED O 1 'moo 'ems _ �'` (2 i 3) PROPOSED DISTRIBUTION BOX x 14.7 4 ell, '! / Z \\ T 3 �.. TP 4` a IP>< ?LT( ATC _3 a -01 v 15x0' \ x14.7 P�1 .. 14x8' : '� 10 S'/� MAP 23 L ►'r LOT 61 /. .. / x14.6 NOTES: 1. MAGNETIC MARKING TAPE SHALL BE PLACED ALONG THE TOP EDGE OF EACH SEPTIC SYSTEM COMPONENT. 2. CONTRACTOR SHALL VERIFY SOIL CONDITIONS IN THE LOCATION OF THE PROPOSED LEACHING FACILITY TO ENSURE CONSISTENCY WITH TEST PIT DATA SHOWN ON THIS PLAN. REPORT TO ENGINEER AND LOCAL BOARD OF HEALTH IF SOILS ARE NOT CONSISTENT WITH TEST PIT DATA. 3. ENTIRE PROPERTY IS NOT LOCATED WITHIN A MASS DEP ZONE II. 4. SWING TIES SHOWN ON THIS PLAN ARE PROVIDED ONLY AS A COURTESY FOR THE INSTALLER. INSTALLER SHALL VERIFY SWING TIE MEASUREMENTS IN THE FIELD PRIOR TO INSTALLING THE SYSTEM. CONTRACTOR SHALL NOTIFY ENGINEER IF MEASUREMENTS APPEAR TO BE INCORRECT IN THE FIELD. 7 �2 ) STUMP -�v X14.5��� /x MAP 23 LOT 60 SITE PLAN SCALE: 1" = 10' PROPOSED SIX (6) LC-6 LEACHING CHAMBERS w/ STONE REMOVE ALL UNSUITABLE MATERIAL DOWN TO "C" SOIL & REPLACE w/ CLEAN, COARSE SAND PER 310 CMR 255(5) 9 W LOCUS PLAN SCALE: 1" =1000' DESIGN DATA NUMBER OF BEDROOMS (EXISTING) 2 NUMBER OF BEDROOMS (DESIGN) 4 DESIGN FLOW 110 GAUDAY/BEDROOM TOTAL DESIGN FLOW 440 GAUDAY DESIGN FLOW x 200 = 880 . GAUDAY MAP 23 USE PROPOSED 1,500 GALLON SEPTIC TANK LOT 62 3/4" TO 1-1/2" DOUBLE WASHED STONE TO CROWN OF PIPE 3" TO 1/2" DOUBLE WASHED ')EOTEXTILE FILTER FABRIC 1. 2. 3. GENERAL NIOTES UNLESS OTHERWISE NOTED, ALL SYSTEM COMPONENTS AND CONSTRUCTION METHODS SHALL BE IN ACCORDANCE WITH TITLE 5 OF THE STATE ENVIRONMENTAL CODE AND ANY APPLICABLE LOCAL RULES. ANY CHANGES TO THIS PLAN MUST BE APPROVED BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4" SCHEDULE 40 PVC PIPE WITH WATER TIGHT JOINTS SHALL BE USED IN DISPOSAL - R ON ALL w/ PIPED SYSTEM UNLESS OTHERWISE NOTED. VITHIN 6" GRADE-""'4. TO PREVENT BREAKOUT, THE PROPOSED FINISHED GRADE SHALL NOT BE LESS THAN ELEVATION = 12.20' FOR A DISTANCE OF IVAROUND THE PERIMETER OF THE SAS. UNLESS A 40 MIL GEOMEMBRANE LINER IS PLACE AT LEAST FIVE FEET FROM S.A.S. AND THE TOP OF O THE LINER IS NOT LESS THAN THE BREAKOUT ELEVATION. 0 5. SLOPE ALL SOLID PIPE AT 1.0% MINIMUM. 0 0 6. THIS SYSTEM IS NOT DESIGNED FOR A GARBAGE DISPOSAL. o0 7. LOCAL BOARD OF HEALTH AND DESIGN ENGINEER TO BE NOTIFIED PRIOR TO BACK FILLING WHEN SYSTEM IS NEARLY COMPLETE AND READY FOR INSPECTION. SYSTEM IS oo NOT TO BE BACK FILLED WITHOUT FIRST OBTAINING APPROVAL FROM BOARD OF HEALTH AND DESIGN ENGINEER. 3.00' 4.0' 8• ELEVATIONS BASED ON N.A.V.D. 88 DATUM. SEE BENCHMARK LOCATION AND ELEVATION (TYP.) SHOWN ON PLAN. 9. CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS PRIOR TO CONSTRUCTION 11.00' THROUGH DIG -SAFE AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE AT CHAMBER END VIEW 1-888-DIG-SAFE AND ANY OTHER APPLICABLE AGENCIES. REPORT ANY DISCREPANCIES TO THE DESIGN ENGINEER. 10. ALL JOINTS WHERE PIPE ENTERS AND EXITS CONC. STRUCTURES SHALL BE MADE WATERTIGHT. _ 11. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING IS TO OBTAIN SUCH DETERMINATION FROM � ` // I EST P I � Df�.TA -D, APPROPRIATE AUTHORITY.PLICANT PERC NO. N/A 12. ALL SEPTIC SYSTEM COMPONENTS SHALL WITHSTAND H-10 LOADING UNLESS LOCATED jj ` INSPECTOR: Barry Lewis (BOH) UNDER MORE THAN 3 FEET OF COVER OR LOCATED UNDER PAVEMENT, DRIVES, OR G EVALUATOR: Michael Pimentel, EIT, CSE TRAVELED WAYS IN WHICH CASE THEY SHALL WITHSTAND H-20 LOADING. 1 � C.S.E. APPROVAL DATE; Oct. 27, 1999 13. DOUBLE WASHED CRUSHED STONE SHALL BE FREE OF ALL DIRT, DUST AND FINES. DATE: July 18, 2024 14. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL LOAM, SUBSOIL AND UNSUITABLE TEST PIT #: 1 & 2 MATERIAL IN AREA BENEATH AND FOR 5 FT. ON ALL SIDES OF LEACHING FACILITY. REPLACE ALL UNSUITABLE MATERIAL WITH CLEAN COARSE SAND FREE FROM CLAY, ELEV TOP = 14.80' FINES OR OTHER UNSUITABLE MATERIAL IN ACCORDANCE WITH 310 CMR 15.255(5). =�1 ELEV WATER = 5.50'* 15. CONTRACTOR SHALL NOTIFY DESIGN ENGINEER OF ANY DISCREPANCIES FOUND IN SITE CONDITIONS FROM THOSE SHOWN PRIOR TO CONTINUATION OF WORK. _ PERC RATE < 2 min./inch 16. PROPOSED PROJECT IS LOCATED WITHIN: DEPTH OF PERC = 4811- 6611 ASSESSOR'S MAP 23 LOT 80 >; TEXTURAL CLASS: I OWNER OF RECORD: DOMENIC CAPOZZI & MARY A. CAPOZZI, TRUSTEES OF THE D & M CAPOZZI FAMILY REVOCABLE TRUST OF 2002 ADDRESS: 410 UPHAM STREET 0 3611 / B lll) 1 48" Perc 6611 i INSTALL (6) LC-6 LEACHING CHAMBERS w/ STONE SIDEWALL CAPACITY (TOTAL PERIMETER) (1' HIGH) (0.74 GPD/S.F.) = GAUDAY (111.0') (1') (0.74 GPD/ S.F.) = 82.1 GAUDAY BOTTOM CAPACITY (FOOTPRINT AREA) (0.74 GPD/S.F.) = GAUDAY (489 S.F.) (0.74 GPD/S.F.) = 361.9 GAUDAY TOTALS: TOTAL NUMBER OF CHAMBERS 6 TOTAL LEACHING AREA 600.0 SQ.FT. TOTAL LEACHING CAPACITY 444.0 GAL./DAY RESERVED FOR BOARD OF HEALTH USE C 111.6" 132" 136" C 111.611 132" 136" 14.80 MELROSE MA 02176 FEMA FLOOD ZONE X & X (<500) COMMUNITY PANEL # 25001CO588J 11.80, 17. DEED REFERENCE: L.C.C. #236207 18. PLAN REFERENCE: L.C. PLAN 11435-A 10.80, 19. ALL DISTURBED AREAS SHALL BE RESTORED TO ORIGINAL CONDITION. 20. PROPERTY LINE INFORMATION IS ONLY APPROXIMATE. THIS PLAN IS TO BE USED ONLY 9.30, FOR SEPTIC SYSTEM UPGRADE. JC ENGINEERING WILL NOT ASSUME ANY LIABILITY FOR USES OF THIS PLAN OTHER THAN ITS INTENDED PURPOSE. 21. OWNER / APPLICANT / CONTRACTOR SHALL BE RESPONSIBLE TO OBTAIN ANY AND ALL REQUIRED PERMITS AND APPROVALS FOR THIS PROJECT. 5.50, 3.80' 3.47' - -- - --- -- TEST PIT DATA PERC NO. N/A INSPECTOR: Barry Lewis (BOH) EVALUATOR: Michael Pimentel, EIT, CSE C.S.E. APPROVAL DATE: Oct. 27, 1999 DATE: July 18, 2G24 TEST PIT #: 3 & 4 ELEV TOP = 15.00, ELEV WATER = 5.70'* PERC RATE _ DEPTH OF PERC = TEXTURAL CLASS: I t1� Fill 4211 1 B Loamy Sand 4811 10Yr 5/6 11.00, Med. to Fine Sand 2.5Y 6/6 Adjusted a�111_6'__ Weeping @ 132" 15.00' LEGEND x50.O' EXISTING SPOT GRADE - - 50 - - EXISTING CONTOUR PROPOSED CONTOUR 50 1 PROPOSED SPOT GRADE AUG 0 6 ?0e4 GAS EXISTING GAS LINE HEALTH DEPT. O f H f W EXISTING OVER HEAD WIRES W W EXISTING WATER LINE E E EXISTING UNDERGROUND ELECTRIC LINE LSA EXISTING LANDSCAPED AREA TEST PIT LOCATION O O O PROPOSED 1,500 GALLON SEPTIC TANK PROPOSED 4" SOLID SCHEDULE 40 PVC PIPE 13 PROPOSED DISTRIBUTION BOX U PROPOSED LC-6 CONCRETE LEACHING CHAMBER REV. DATE BY APP'D. DESCRIPTION _ PROPOSED SEPTIC SYSTEM PLAN P�,�A ❑F MASs�c PREPARED FOR �d JOH N L. y��^S„ o CHURCHILL R. ROBERT B. OUR CO., INC. CIVIL N0. 066 ,r� j rsr LOCATED AT 5.70' L ,3 10 MERRYMOUNT ROAD ( WEST YARMOUTH, MA 02673 4.00' --I SCALE: 1 INCH = 10 FT. DATE: AUGUST 1, 2024 3.67' 0 5 10 20 40 FEET *BASED ON THE CAPE COD COMMISSION METHOD INDEX WELL: MIW 29 WATER -LEVEL RANGE ZONE: B WATER DEPTH READING: 7_4' WATER DEPTH READING DATE: 6-20-24 WATER -LEVEL ADJUSTMENT: 1.7' (20.4") OF M,4 _ _ ° JOHN L. otiG�IriT PREPARED BY CHURCHILL JR. CIVIL ; JC ENGINEERING, INC. `� NO. 41 D7 2854 CRANBERRY HIGHWAY EAST WAREHAM, MA 02538 508.273.0377 T�. Drawn By: JTC Designed By: MCP I Checked By: JLC JOB No. 7921