HomeMy WebLinkAboutEngineer PlanLEGEND 99 - EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. -[99]--- PROPOSED CONTOUR [98.4] PROPOSED SPOT EL TH1 TEST HOLE SLOPE OF GROUND UTILITY POLE FIRE HYDRANT NOTE: NOT ALL SYMWLS MAY APPEAR IN DRAWING \� c SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED EXISTING 6 BEDROOM DWELLING DESIGN FLOW: 6 BEDROOMS ® 110 GPD = 660 GPD USE A 660 GPD DESIGN FLOW SEPTIC TANK: §60 GPD (2) = 1320 USE EXISTING 2,500 GAL. DUAL COMPARTMENT SEPTIC TANK LEACHING: SIDES: 2 (50.5 + 12.83) 2 (.74) = 188 GPD BOTTOM 50.5 x 12.83 (.74) = 479 GPD TOTAL: 901 S.F. 667 GPD USE (5) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE AL AROUND MA APPROVED DATE BOARD OF HEALTH Dd o d 0 LOT C , 25 00 AREA: 2000SF. AC 0.46 . EXISTING LEACHI G 'STEM PROFILE ALL sYsrEM COMPONENTS SHALT BE t MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LACA11ON. (NOT TO SCJU-E) ACCESS COVERS TO WITHIN 6" OF FIN. GRADE 2" pEASTONE OR GEOTEXTILE CONCRETE COVERS TO WITHIN 3" GRADE FIRST FLOOR EL. 19.8' FILTER FABRIC OVER STONE 2% SLOPE REQUIRED OVER SYSTEM 20.0 \ m� \fib,, 2 WATERTEST D BLOCKS OR BOX FOR LEVELNESS PRECAST RISERS INV. IN *15.39' 4"OSCH40 PVC MORTAR ALL INVERT IN 17.67' 2" PRESSURE LINE PROP. TEE PIPES LEVEL 1ST 2' 4' COMPONENTS 4' TO DRAIN BACK �EN DS (') SIDES 18.5 ,• SLOPE e o 19" TEE 1000 GAL. e� .� °°u0 a� ZABEL FILTER °°°o °° p� ((�� �® �B®- ®®® ;�oao0b�o >°°°O °°O OL��®®®®®®® ®®® °°°O°�°o° OUTLET TEE 1500 GAL. ° C C ° ° ®® ����jj® ®® ® °°°° °000 O° ° ° ° ) ° ° > °°°°° ° ®®® �® ®®® ®® °°Op°°° W/EXTENSION COMPARTMENT °^°1°^ °000015.67 17.91' °°°°°°°° 6' MIN. SUMP „!• ? 12' MIN. INT. DIM. 4" LE WASHED STONE 4' MIN. H-10 500 GAL. LEACHING CHAMBERS BY ACME PRECAST OR EQUAL, 5�� 3"-1-10ooao �� �� / /2DOUB(5) UNITS REQUIRED EXISTING 2500 GAL SEPTIC TANK/ ALL AROUND PRECAST STRUCTURES PUMP CHAMBER COMBINATION 6" CRUSHED STONE OR MECH�.NICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 50.50' X 12.83' COMPACTION. (15.221 (21) *THE INSTALLER SHALL VERIFY THE (1.0 % SLOPE) LOCATIONS OF ALL UTILITIES AND ALL LEACHING TH-1 BUILDING SEWER OUTLETS AND PUMP CHAMBER 21' D' I30X 24' FACILITY GROUNDWATER FOUND ELEVATIONS PRIOR TO INSTALLING ANY AT EL. 10.5' PORTION OF SEPTIC SYSTEM 0.00' ADJ. VARIANCES REQUESTED: UNDER MAX. FEASIBLE COMPLIANCE 15.405: (1 a): REDUCTION IN SETBACK, SAS TO LOT LINE (10' TO 5.0') (1 b): REDUCTION IN SETBACK, SAS TO FOUNDATION (20' TO 10.8) 21 10 0, PROVIDE 63' OF 40 MIL LINER AT 5' 0 SAS IN AREA SHOWN. OP AT ELEV. 20.0', BO 0 AT EL. 15.0'f 5' REM VAL OF UNSUITABLE SOIL REQUIRED AROUND PERIMETER OF LEACH G FACILITY, DOWN TO SUITABLE SOIL LAYER. REPLACE WITH 4EAN MED. SAND, TO MEET SP CI CATIONS OF 310 CMR 1 55(3) E TING LEAC ING #2 TO BE. REMOVED OFFICE LIVING KITCHEN ROOM BATH I DINING ROOM ROOM BED ROOM - F IN me ROOM GARAGE UVI N G ROOM KITCHEN _ BED (BATH ROOM ROOM LIVING ROOM 2ND FLOOR BED ROOM FLOOR PLAR NOOT BATH ROOM m 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1 /8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-LQ 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (811) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED BENEATH AND 5' AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED LEACHING #2. 13. OWNER'S ENGINEER TO PERFORM INSPEC11ONS OF THE FINAL INSTALLATION. MINIMUM OF 24 HOURS NOTICE REQUIRED. 14. EXISTING 2,500 GAL DUAL COMPARTMENT SEPTIC TANK & PUMP TO REMAIN. 15. OWNER'S ENGINEER TO INSPECT PUMP & ALARM PRIOR TO BACKFILL OF PROPOSED LEACHING FIELD. SOIL EVALUATOR: JOHN DOYLE DATE: 12/4/01 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS ELEV. 0" 19.5' 0 /A 11" LS / 1 CYR 6/6 34" ///// 16.7' MS / 89" 2.5Y 8/4 12.1' C2 SiCL �/5Y 7/3 101" /iii C3 CS 1 CYR 8/6 124" 9.2' GROUNDWATER ENCOUNTERED AT 123" EL. 9.3' LOCUS MAP SCALE 1 "=2000't ASSESSORS MAP 141 PARCEL 32 LOCUS IS WITHIN FEMA FLOOD ZONE X (AREA OF MINIMAL FLOOD HAZARD) AS SHOWN ON COMMUNITY PANEL #25001CO578J DATED 7/16/2014 SITE IS NOT WITHIN STATE DESIGNATED NSA ENGINEER: CRAIG J. FERRARI, SE #13871 WITNESS: BARRY LEWIS DATE: 5/ 16/24 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS ELEV. 0„ v 19.0' A LS 1CYR 3/2 24" ///// LS 1CYR 5/8 60' r //// 14' C1 ® UNSUITABLE SOIL PERC FS 2.5Y 7/4 G-W ADJ. DATA. WELL: SDW-252R ZONE: A ADJ: 0.00' APRIL 2024 132" I ' 8' GROUNDWATER ENCOUNTERED AT 102" EL. 10.5 Yarrenth Herlth Departr:ient 0VED i N mmum R to PLAN OF #44 HO'L V1 C Y A R'mhm 0 U T 'rim PU` R' Ty MA PREPARED FOR W A / ETA C A -kNAHOILL DATE: J U N E 5, 2024 ��ti� ►,�4�� Scale:1 "= 20' A G3CGrCO�ICDD OF &Vtq \A\�+a` 0 10 20 30 AUG 40 50 FEET il�iNIELt-\Gn\:� r: Q� V;L G`r OJV,LA �f'1cS j, `f� ,PT. dJ \fin. G�7liL i" � \a: N'. 40980 � � •�, �� � off 508-362-4541 fax 508-362-9880 • l F- downcaP e.com SURIJ Ng civil engineers land surveyors gig Main Street ( Rte 6A) SURVEY: QAH YARMOUTHPORT MA 02675 DRAFTED BY: CJF/PTT DATE DANIEL A. OJALA, P.E., P.L.S. CHECKED BY: 24-107 CAHILL.DWG DCE #24-107