Loading...
HomeMy WebLinkAboutEngineer PlanI UP UP FOUNDATION EL 21 5 GROUND SURFACE GROUND SURFACE Ems_ 0 " MIN UID LEVEL �� AID" 14., �L INVERT / -Z EL GAS BAFFLE AT OUTLET INVERT EL J 6" STONE BASE 1500 Gal Septic Tank 35 ' (1N. Z°) OUTLET PIPE LEVEL FIRST TWO FEET /-0 O VENT REQUIRED D-BOX �y9 o 0 0 0 0 0 0 0 0 INVERT RL (A _ 7 D) Z 3' 5 0 o a o o cl o r� o INVERT EL 2�.a 2"-. b Tojr ;k. Z,) INVERT EL INVERT EL I� c l r u t.1 3 3 U �%^' ► 15 S, 33�� I 3t I I 1 NOTE.- Install ejector pump in bathroom in basement and plumb to proposed new outlet pipe at elevation 25.7. / , 00 261 E PROPOSED LEACHING FACILITY / / 95 Four Cultee Reebarger 330 Units (N z �) with 3' stone on ends and 4' / /O stone on 5101j (Total 36' x 12.3i•) / / ��11 j�]�V 7, � / / •r. 1 , f�/ J i 1 ul IV T M Prop. - w C _ D—box - H-20 Prop. r 1, 500 Gal 6 S—tank � O 1 H-20 / cp �v M� \T • Ex j ST l _ Exist, `� O O 1� / Ga ego Catch Ba-si M , �i / , / St pT1c �fl�;L Lm e-o `�--- _ to -be removgd 24 Instal' 2° a CO. to A0, 0 Lo nR cn 4 7, 800-1- Sq. Ft. 3 "Exist In Y Install Et - 3,D{ / / new outlet, / / / / / , QL�M9 1/J1, 1,4 Ns / / -,Z A, \pipe t9) el ///////,Bldg ����,//////// / i / / / T,0^-0 0 IN " 1-1 \\ *de) \\ __AL AL WEIR AL `C STRI'A Y r A& E'd�e Of Wa Ier TOP EL MIN 2' LAYER DOUBLE WASHED 1/8'- 1/2' STONE EFFEC= SIDEWALL 3/4'- 1 1/2' DOUBLE WASHED STONE 2� BOTTOM EL — EL [6 -S OF TEST HOLE . WiNSLOW 'V, f M. 11 x gpOFFORD No?� No su STANDARD NOTES 1) THIS PLAN IS FOR THE INSTALLATION OF A SEPTIC SYSTEM. 2) ALL INSTALLATION PROCEDURES AND MATERL4LS SHALL CONFORM TO 310 CMR 15.000, THE STATE ENVIRONMENTAL CODE, TITLE 5, AND THE TOWN OF -_ Ya_rm0__u_thP0Tt_ SUBSURFACE DISPOSAL REGULATIONS 3) NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE OF A VAILABLE PROPERTY INFORMATION WITH RECORDED DEEDS OR ZONING REGULATIONS. 4) TOWN WATER SERVICES THIS PROPERTY. 5) THERE ARE NO KNOWN PRIVATE WEIJ.5 ON Z71IS PROPERTY OR WITHIN 100' OF THE PROPOSED SOIL ABSORPTION SYSTEM. 6) ALL COVERS OF SYSTEM COMPONENTS SHALL BE BROUGHT TO WITHIN 12" OF FINISHED GRADE, WITH ONE COVER OF THE SEPTIC TANK BROUGHT #7771IN 6" OF GRADE. 7) ALL SYSTEM COMPONENTS SHALL REMAIN ACCESSIBLE FOR INSPECTION. NO STRUCTURES SHALL BE LOCATED DIRECTLY UPON OR ABOVE THE COMPONENT ACCESS LOCATIONS, WHICH WOULD INTERFERE WITH THE PERFORMANCE, ACCESS, INSPECTION PUMPING OR REPAID 8) NO DRIVEWAY, PARKING OR TURNING AREA, OR OTHER IMPERVIOUS AREA SHALL BE LOCATED ABOVE A SOIL ABSORPTION SYSTEM EXCEPT WHEN VENTING HAS BEEN PROVIDED. 9) !I SEPTIC TANKS, GREASE TRAPS, DOSING CHAMBERS AND DISTRIBUTION BOXES SHALL BE PLACED ON A 6" STONE BASE TO ENSURE STABILITY AND PREVENT SETTLING. 10) OUTLET DISTRIBUTION LINES SHALL REMAIN LEVEL FOR A MINIMUM OF 77IE FIRST TWO FEET OF THEIR LENGTH Il) ',i ALL SYSTEM COMPONENTS SHALL BE CAPABLE OF TITHSTANDING H-ID LOADING UNLESS THEY ARE UNDER OR WITHIN 10' OF DRIVEWAYS OR PARKING OR TURNING AREAS, IN WHICH CASE H-20 COMPONENTS SHALL BE USED. 12) I ALL BUILDING SEWER LINES SHALL HAVE AN INNER DIAMETER OF 4- AND SHALL BE CAST-IRON OR SCHEDULE 40 PVC. 13) THE DEPTH OF THE TOP OF ALL SYSTEM COMPONENTS SHALL NOT EXCEED 36" UNLESS VEN7IIYG HAS BEEN PROVIDED. 14) IN THE AREAS OF EXCAVATION, EXISTING GRADES SHALL BE REESTABLISHED UNLESS NOTED AS PROPOSED CONTOURS. 15) IF SOILS ARE ENCOUNTERED DURING THE EXCAVATION OF THE SOIL ABSORPTION SYSTEM, THAT DIFFER NOTABLY FROM THE DEEP OBSERVATION HOLE LOG, CONTACT THE ENGINEER BEFORE PROCEEDING. 16) CONTRACTOR TO VERIFY LOCATION OF ALL UNDERGROUND UTILITIES. MAXIMUM FEASIBLE COMPLIANCES 1.) VARIANCE TO THE 10 ' _ SETBACK BETHWEN THE EDGE OF THE LEACHING FIELD AND THE _ NORTHE_RL Y PROPERTY LINE A --A _ __ SETBA CK IS PRO MED. (TITLE5 SECTION 15.211(1)) 2) VARIANCE TO THE _ 20 ' SETBACK BETWEEN THE EDGE OF THE LEACHING FIELD AND THE EXISTING BUILDING. A 15 SETBACK IS PROVIDED. (TITLE 5 SECTION 15.211(1) WlM SPOFFORD H t 203b3 r, DESIGN DATA Number of Bedrooms: 4 Garbage Grinder. NO Design new U t f U (110 Gal/BR/Day x Number of BR) Septic Tank: 1, 5e O (Minimum = Design Flow x 200%) \ Leaching Area: SidewalL• z (t Sidewalls x 1 x 2 Ft) + ( Z Endwalls x _12 -3--t x Bot , om: q` q Z 3e n x I'Z (03 5 5F Long Term Acceptance Rate (LTAR): 0.74 Leaching Area Design Capacity. Lf -70 G e0 (Sidewell Area + Bottom Area) x LTAR DEEP OBSERVATION HOLE LOG Test Hole #f (EL = 27 O t) Drth in Trey tt Horizon Horizon TortSure t90 clollt (USDA) (Munsell) 0 - e" 2l,-5 A LOAMY SAND IOYR3/2 8" - 22" Z5.-L D LOAMY SAND 7.5YR5/6 22" - 126" Ib C COARSE SAND IOYR5/6 Deep Obs Hole Date: JUNE 24, f999 So❑ Evaluator. ED STONE Witnessed By: AMY VON HORNE Pere Rate: < 2 MIN/IN 067" Soil Survey Description: CARVER Geologic Materiel- OUT1IdSH Depth to Standing hater. NA Depth to Weeping Water NA Depth to Mottling(Color): NA Est Seasonal High GW. NA USGS Observation Welk NA Date of last Measurement- NA Comments: f�:uz� �rlf /,FF�LIf PROJECT LOCATION 39 Merchant Lane Yarmouthport, MA ASSFSSORS MAP 12 % LOT 40 ' U1� l � t� �--� •� LU�C v -� APPLICANT Ray Bernier 26 Ward Road So u th b oro u h, MA 01772 PREPARED BY A & M Land Seri ces 33 Old Main Street South Yarmouth, MA 02664 (508) 398-2121 Fax 394-9642 SCALE' I" — 2 0 ' DA TE., June 29, 1999 LOCUS MAP REV. 8 a`1 Ada ��ot� , VA,f2 1 39 Merchant Lane Yarmouthport, MA DWG. NO. 99,23 SHEET 1 OF 1 HIECEOWEDD J U L 0 8 1999 HEALTH DEPT.