HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. , ?p2 Lot J ec Q Zone of Contribution: In Out_ Acreage 2Oo
/ Commercial: Residential: i-
Street: I/o R„; ,,,, L,D(.., 1S
Village: Floor Plan: #Bedrooms: ..
Address: pc,v / ��CJ C G Installer: ,S 0 /� c% S rr �p
Phone: �, l7 6-9_, - 777_.3
Phone: C, i 7 7 6 -- . ‘r)n
Builder: Engineer: 1)C G-4 rND C, c-`
Address: Phone: 6-0 8 3 ,,_ - L/6 r,,
4/
Phone:
N/A YEy NO
1. Required#of copies received
2. Date of soils exam and percolation test not older than 2 years
3. 4-5 ft of naturally occurring pervious material,above water table
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.:
5.Water line 10 ft from septic components Var.:
6.Benchmark indicated and shown-NGVD if near wetlands Y
7. Septic tank minimum 10 ft from foundation, deck Var.:
8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.:
9.Leaching minimum 100 ft from wetlands Var.:
10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.:
11.Tank/leaching minimum 10 ft from property line Var.: V
12. System meets all other setback requirements Var.:
13.Uses adjustment for maximum high groundwater Var.: 1 ✓
14. Leaching set 4-5 ft above adj.water or bottom of test hole Var.` '7.
15. System not in top or subsoil(A,B horizons) or 5' removal
16.Proposed contours are suitable
17. System meets slope requirements-min. 1/8", 1/4"preferred
18. System meets breakout requirements PVC liner: Wall: ,\ .
19. Specified tee sizes are proper,gas baffle on outlet tee ti/".
20. Sewage is under 10,000 gpd for parcel N/
21.No garbage disposal -./
22. System adequately sized for its intended use ,
23.Minimum 6"stone or compacted below tank and dbox
24.Manhole covers within 6"of grade,pump chamber cover to grade \�
25. Inspection port on plastic chambers/leach field ✓
26. Electrical permit for pump chamber/Separate meter for duplexes
27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size '\/
28. Septic tank/pump chamber to be factory waterproofed \ --
29. Vent provided if leaching below 3 feet,under driveway/parking V
30.Buoyancy calculations for tank/pump chamber V
31. Engineer to inspect and certify soils: wall: commercial: v
32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature
33.H-20 loading is subject to vehicular traffic, groundwater f
34.Title V Application and permit fee, installer signature \/
35.Foundation footing min.2 feet above adjusted ground water for new house ✓ .
36. Deed Restriction required max. #bedrooms: max. flow: gpd V
37. Check area lots for groundwater/Label groundwater in Assessor's Map
Plan reviewed by: 60101