Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. , ?p2 Lot J ec Q Zone of Contribution: In Out_ Acreage 2Oo / Commercial: Residential: i- Street: I/o R„; ,,,, L,D(.., 1S Village: Floor Plan: #Bedrooms: .. Address: pc,v / ��CJ C G Installer: ,S 0 /� c% S rr �p Phone: �, l7 6-9_, - 777_.3 Phone: C, i 7 7 6 -- . ‘r)n Builder: Engineer: 1)C G-4 rND C, c-` Address: Phone: 6-0 8 3 ,,_ - L/6 r,, 4/ Phone: N/A YEy NO 1. Required#of copies received 2. Date of soils exam and percolation test not older than 2 years 3. 4-5 ft of naturally occurring pervious material,above water table 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: 5.Water line 10 ft from septic components Var.: 6.Benchmark indicated and shown-NGVD if near wetlands Y 7. Septic tank minimum 10 ft from foundation, deck Var.: 8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 9.Leaching minimum 100 ft from wetlands Var.: 10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: 11.Tank/leaching minimum 10 ft from property line Var.: V 12. System meets all other setback requirements Var.: 13.Uses adjustment for maximum high groundwater Var.: 1 ✓ 14. Leaching set 4-5 ft above adj.water or bottom of test hole Var.` '7. 15. System not in top or subsoil(A,B horizons) or 5' removal 16.Proposed contours are suitable 17. System meets slope requirements-min. 1/8", 1/4"preferred 18. System meets breakout requirements PVC liner: Wall: ,\ . 19. Specified tee sizes are proper,gas baffle on outlet tee ti/". 20. Sewage is under 10,000 gpd for parcel N/ 21.No garbage disposal -./ 22. System adequately sized for its intended use , 23.Minimum 6"stone or compacted below tank and dbox 24.Manhole covers within 6"of grade,pump chamber cover to grade \� 25. Inspection port on plastic chambers/leach field ✓ 26. Electrical permit for pump chamber/Separate meter for duplexes 27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size '\/ 28. Septic tank/pump chamber to be factory waterproofed \ -- 29. Vent provided if leaching below 3 feet,under driveway/parking V 30.Buoyancy calculations for tank/pump chamber V 31. Engineer to inspect and certify soils: wall: commercial: v 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature 33.H-20 loading is subject to vehicular traffic, groundwater f 34.Title V Application and permit fee, installer signature \/ 35.Foundation footing min.2 feet above adjusted ground water for new house ✓ . 36. Deed Restriction required max. #bedrooms: max. flow: gpd V 37. Check area lots for groundwater/Label groundwater in Assessor's Map Plan reviewed by: 60101