HomeMy WebLinkAbout24-A118 46 Summer Street_DD Set_OKH Meeting (2024.08.28)_Red MarksFirst Floor
0' -0"
Second Floor
8' -2"
Attic Floor
16' -0 1/2"
Roof Ridge Height
22' -11 1/2"
New Sunroom Addition
Replace windows & add shutters, TYP.
Replace asphalt shingel w/
cedar roof shingle
Replace eave, rake trims & gutter
New Entry Foyer Addition
Replace asphalt shingle w/ cedar shingle roofing
New addition w/ Cedar Shingle Roof
New Porch & Mudroom
New Cedar Roof
New Windows & Trims at New Additions
New Brick Veneer
@ Main House
New Stone Cap & Brick Veneer
New Brick Veneer
@ Sunroom
New Cornerboard
4"
12"
3"
12"
4"
12"
B.O. Ceiling Joists
17' -6 1/4"
Rebuild Chimney
First Floor
0' -0"
Second Floor
8' -2"
Attic Floor
16' -0 1/2"
Roof Ridge Height
22' -11 1/2"
Drawing Number:
Checked:
Project Number:
Drawn:
Registration:
Issue Dates and Revisions:
Drawing Title:
General Notes:
General Contractor shall make all Subcontractors and
Suppliers aware of the requirements of these notes.
All work shall be performed in compliance with all
applicable Local, State and National Building, Life Safety
and Electrical Codes.
General Contractor shall be responsible for securing all
permits as necessary for the completion of work shown
throughout the Contract Documents.
General Contractor shall lay out in the field the entire
work to verify dimensional relationships before
constructing any part, and shall verify all existing
conditions and locations before proceeding.
Failure to verify dimensions and conditions before
proceeding may subject the General Contractor to the
required removal of completed work at General Contractor
cost, if a discrepancy which could have been discovered
causes modifications to the plans.
General Contractor shall coordinate the dimensional
requirements between the work of the various trades.
Any discrepancies found in the plans, dimensions, existing
conditions or any apparent error in the classifying or
specifying of a product, material or means of assembly is
to be pointed out to the Architect immediately.
Drawings shall not be scaled for dimensions and/or sizes.
Owner and Architect assume no responsibility for use of
incorrect scale.
Regardless of whether or not an item is shown or
specified, General Contractor shall provide said item if it
is necessary for the proper installation or function of an
item shown or specified. Suppliers and Subcontractors
shall inform the General Contractor of their requirements
for the work of other trades, which may not be indicated,
prior to bidding.
All dimensions to interior/exterior walls indicated are to
face of stud wall or concete/c.m.u. unless noted otherwise.
Copyright Note:
Meyer and Meyer Inc., expressly reserves the Common
Law Copyrights and other Property Rights in these plans.
These drawings are the property of Meyer and Meyer Inc.,
and shall not to be reproduced in any manner, nor are they
to be assigned to any third party without first obtaining the
expressed written permission and consent of Meyer and
Meyer Inc.
Project:File Location: L:\Titleblocks\24x36Titleblock-New.dwgMEYER & MEYER
ARCHITECTURE AND INTERIORS
T: 617.266.0555
F: 617.266.2952
396 Commonwealth Avenue
Boston, Massachusetts 02215
Summer Street
Realty Trust
46 Summer Street,
Yarmouth Port, MA
A2.00
Exterior
Elevations
##########
Checker
Ryota Uchida
Design Development August 28, 2024
1/4" = 1'-0"
1 Proposed West Elevation
1/4" = 1'-0"
2 Existing West Elevation
First Floor
0' -0"
Second Floor
8' -2"
Attic Floor
16' -0 1/2"
Roof Ridge Height
22' -11 1/2"
New Eave, Rake, & Gutter
New Windows w/ New Trims
New Entry Foyer Addition
Rebuild Bay Window
New Dormer w/ Copper Roof
Replace Window w/ New Trims
Replace Asphalt Shingle w/ Copper
New Sunroom Addition
New Wood Bulkhead
New Brick Veneer
New Dormer w/ Cedar Shingle
New Stone Cap & Brick Veneer
New Cornerboard
New Downspout
New Cornerboard
9"
12"
9"
12"
3 1/2"
12"
2"
12"
3 1/2"
12"
3 1/2"
12"
2"
12"
2"
12"B.O. Ceiling Joists
17' -6 1/4"
Rebuild Chimney
First Floor
0' -0"
Second Floor
8' -2"
Attic Floor
16' -0 1/2"
Roof Ridge Height
22' -11 1/2"
Drawing Number:
Checked:
Project Number:
Drawn:
Registration:
Issue Dates and Revisions:
Drawing Title:
General Notes:
General Contractor shall make all Subcontractors and
Suppliers aware of the requirements of these notes.
All work shall be performed in compliance with all
applicable Local, State and National Building, Life Safety
and Electrical Codes.
General Contractor shall be responsible for securing all
permits as necessary for the completion of work shown
throughout the Contract Documents.
General Contractor shall lay out in the field the entire
work to verify dimensional relationships before
constructing any part, and shall verify all existing
conditions and locations before proceeding.
Failure to verify dimensions and conditions before
proceeding may subject the General Contractor to the
required removal of completed work at General Contractor
cost, if a discrepancy which could have been discovered
causes modifications to the plans.
General Contractor shall coordinate the dimensional
requirements between the work of the various trades.
Any discrepancies found in the plans, dimensions, existing
conditions or any apparent error in the classifying or
specifying of a product, material or means of assembly is
to be pointed out to the Architect immediately.
Drawings shall not be scaled for dimensions and/or sizes.
Owner and Architect assume no responsibility for use of
incorrect scale.
Regardless of whether or not an item is shown or
specified, General Contractor shall provide said item if it
is necessary for the proper installation or function of an
item shown or specified. Suppliers and Subcontractors
shall inform the General Contractor of their requirements
for the work of other trades, which may not be indicated,
prior to bidding.
All dimensions to interior/exterior walls indicated are to
face of stud wall or concete/c.m.u. unless noted otherwise.
Copyright Note:
Meyer and Meyer Inc., expressly reserves the Common
Law Copyrights and other Property Rights in these plans.
These drawings are the property of Meyer and Meyer Inc.,
and shall not to be reproduced in any manner, nor are they
to be assigned to any third party without first obtaining the
expressed written permission and consent of Meyer and
Meyer Inc.
Project:File Location: L:\Titleblocks\24x36Titleblock-New.dwgMEYER & MEYER
ARCHITECTURE AND INTERIORS
T: 617.266.0555
F: 617.266.2952
396 Commonwealth Avenue
Boston, Massachusetts 02215
Summer Street
Realty Trust
46 Summer Street,
Yarmouth Port, MA
A2.01
Exterior
Elevations
##########
Checker
Ryota Uchida
Design Development August 28, 2024
1/4" = 1'-0"
1 Proposed South Elevation
1/4" = 1'-0"
2 Existing South Elevation
First Floor
0' -0"
Second Floor
8' -2"
Attic Floor
16' -0 1/2"
Roof Ridge Height
22' -11 1/2"
New Dormer w/ Cedar Shingle
Existing Roof Ridge Line to Remain
New Dormer w/ Copper Roof Replace Existing Asphalt Shingle w/
Cedar Roof
Replace Door & Add New Window
Replace Windows w/ New Trims
Replace Windows w/
New Trims
New Sunrrom Addition
Replace Existing Asphalt Shingle w/
New Cedar Shingle Roof
Replace Door w/ New Trims
Rebuild New Shower
Replace Existing Asphalt Shingle w/
Copper Roof
New Bay Window at New Dormer
New Cornerboard
New Cornerboard
B.O. Ceiling Joists
17' -6 1/4"
Rebuild Chimney
First Floor
0' -0"
Second Floor
8' -2"
Attic Floor
16' -0 1/2"
Roof Ridge Height
22' -11 1/2"
Drawing Number:
Checked:
Project Number:
Drawn:
Registration:
Issue Dates and Revisions:
Drawing Title:
General Notes:
General Contractor shall make all Subcontractors and
Suppliers aware of the requirements of these notes.
All work shall be performed in compliance with all
applicable Local, State and National Building, Life Safety
and Electrical Codes.
General Contractor shall be responsible for securing all
permits as necessary for the completion of work shown
throughout the Contract Documents.
General Contractor shall lay out in the field the entire
work to verify dimensional relationships before
constructing any part, and shall verify all existing
conditions and locations before proceeding.
Failure to verify dimensions and conditions before
proceeding may subject the General Contractor to the
required removal of completed work at General Contractor
cost, if a discrepancy which could have been discovered
causes modifications to the plans.
General Contractor shall coordinate the dimensional
requirements between the work of the various trades.
Any discrepancies found in the plans, dimensions, existing
conditions or any apparent error in the classifying or
specifying of a product, material or means of assembly is
to be pointed out to the Architect immediately.
Drawings shall not be scaled for dimensions and/or sizes.
Owner and Architect assume no responsibility for use of
incorrect scale.
Regardless of whether or not an item is shown or
specified, General Contractor shall provide said item if it
is necessary for the proper installation or function of an
item shown or specified. Suppliers and Subcontractors
shall inform the General Contractor of their requirements
for the work of other trades, which may not be indicated,
prior to bidding.
All dimensions to interior/exterior walls indicated are to
face of stud wall or concete/c.m.u. unless noted otherwise.
Copyright Note:
Meyer and Meyer Inc., expressly reserves the Common
Law Copyrights and other Property Rights in these plans.
These drawings are the property of Meyer and Meyer Inc.,
and shall not to be reproduced in any manner, nor are they
to be assigned to any third party without first obtaining the
expressed written permission and consent of Meyer and
Meyer Inc.
Project:File Location: L:\Titleblocks\24x36Titleblock-New.dwgMEYER & MEYER
ARCHITECTURE AND INTERIORS
T: 617.266.0555
F: 617.266.2952
396 Commonwealth Avenue
Boston, Massachusetts 02215
Summer Street
Realty Trust
46 Summer Street,
Yarmouth Port, MA
A2.02
Exterior
Elevations
##########
Checker
Ryota Uchida
Design Development August 28, 2024
1/4" = 1'-0"
1 Proposed East Elevation
1/4" = 1'-0"
2 Existing East Elevation
First Floor
0' -0"
Second Floor
8' -2"
Attic Floor
16' -0 1/2"
Roof Ridge Height
22' -11 1/2"
Replace Eave, Rake Trims & Gutter
New Dormer Addition
New Entry Foyer Addition
Replace/ Add Windows
Replace/ Add New Trims
New Mudroom & Entryway Addtion
Replace Windows w/ New Trims
Remove Existing Window & Relocate to Garage
New Brick Veneer
Existing Roof to Remain w/
New Cedar Shingle & New Roof Trims
New Cornerboard
2"
12"
3 1/2"
12"
9"
12"
8 1/2"
12"
8 1/2"
12"
B.O. Ceiling Joists
17' -6 1/4"
3"
12"
Rebuild Chimney
9"
12"
First Floor
0' -0"
Second Floor
8' -2"
Attic Floor
16' -0 1/2"
Roof Ridge Height
22' -11 1/2"
Drawing Number:
Checked:
Project Number:
Drawn:
Registration:
Issue Dates and Revisions:
Drawing Title:
General Notes:
General Contractor shall make all Subcontractors and
Suppliers aware of the requirements of these notes.
All work shall be performed in compliance with all
applicable Local, State and National Building, Life Safety
and Electrical Codes.
General Contractor shall be responsible for securing all
permits as necessary for the completion of work shown
throughout the Contract Documents.
General Contractor shall lay out in the field the entire
work to verify dimensional relationships before
constructing any part, and shall verify all existing
conditions and locations before proceeding.
Failure to verify dimensions and conditions before
proceeding may subject the General Contractor to the
required removal of completed work at General Contractor
cost, if a discrepancy which could have been discovered
causes modifications to the plans.
General Contractor shall coordinate the dimensional
requirements between the work of the various trades.
Any discrepancies found in the plans, dimensions, existing
conditions or any apparent error in the classifying or
specifying of a product, material or means of assembly is
to be pointed out to the Architect immediately.
Drawings shall not be scaled for dimensions and/or sizes.
Owner and Architect assume no responsibility for use of
incorrect scale.
Regardless of whether or not an item is shown or
specified, General Contractor shall provide said item if it
is necessary for the proper installation or function of an
item shown or specified. Suppliers and Subcontractors
shall inform the General Contractor of their requirements
for the work of other trades, which may not be indicated,
prior to bidding.
All dimensions to interior/exterior walls indicated are to
face of stud wall or concete/c.m.u. unless noted otherwise.
Copyright Note:
Meyer and Meyer Inc., expressly reserves the Common
Law Copyrights and other Property Rights in these plans.
These drawings are the property of Meyer and Meyer Inc.,
and shall not to be reproduced in any manner, nor are they
to be assigned to any third party without first obtaining the
expressed written permission and consent of Meyer and
Meyer Inc.
Project:File Location: L:\Titleblocks\24x36Titleblock-New.dwgMEYER & MEYER
ARCHITECTURE AND INTERIORS
T: 617.266.0555
F: 617.266.2952
396 Commonwealth Avenue
Boston, Massachusetts 02215
Summer Street
Realty Trust
46 Summer Street,
Yarmouth Port, MA
A2.03
Exterior
Elevations
##########
Checker
Ryota Uchida
Design Development August 28, 2024
1/4" = 1'-0"
1 Proposed North Elevation
1/4" = 1'-0"
2 Existing North Elevation