HomeMy WebLinkAbout24-A118 46 Summer Street_DD Set_OKH Meeting (2024.08.28)_GarageFirst Floor
0' -0"
B.O. Ceiling Joists
7' -11 9/16"
Ridge Height
17' -2"
Replace Rake Trims
Replace Existing Window w/
New Trims & Shutters
Replace Garage Door w/
New Trims
Replace Shingle Siding w/
Clapboard
First Floor
0' -0"
B.O. Ceiling Joists
7' -11 9/16"
Ridge Height
17' -2"
First Floor
0' -0"
B.O. Ceiling Joists
7' -11 9/16"
Ridge Height
17' -2"
Replace Existing Asphalt Shingle w/
Cedar Roof Shingle
Replace Eave/ Rake Trims
Replace Gutter
Replace Door w/
New Trims
First Floor
0' -0"
B.O. Ceiling Joists
7' -11 9/16"
Ridge Height
17' -2"
Drawing Number:
Checked:
Project Number:
Drawn:
Registration:
Issue Dates and Revisions:
Drawing Title:
General Notes:
General Contractor shall make all Subcontractors and
Suppliers aware of the requirements of these notes.
All work shall be performed in compliance with all
applicable Local, State and National Building, Life Safety
and Electrical Codes.
General Contractor shall be responsible for securing all
permits as necessary for the completion of work shown
throughout the Contract Documents.
General Contractor shall lay out in the field the entire
work to verify dimensional relationships before
constructing any part, and shall verify all existing
conditions and locations before proceeding.
Failure to verify dimensions and conditions before
proceeding may subject the General Contractor to the
required removal of completed work at General Contractor
cost, if a discrepancy which could have been discovered
causes modifications to the plans.
General Contractor shall coordinate the dimensional
requirements between the work of the various trades.
Any discrepancies found in the plans, dimensions, existing
conditions or any apparent error in the classifying or
specifying of a product, material or means of assembly is
to be pointed out to the Architect immediately.
Drawings shall not be scaled for dimensions and/or sizes.
Owner and Architect assume no responsibility for use of
incorrect scale.
Regardless of whether or not an item is shown or
specified, General Contractor shall provide said item if it
is necessary for the proper installation or function of an
item shown or specified. Suppliers and Subcontractors
shall inform the General Contractor of their requirements
for the work of other trades, which may not be indicated,
prior to bidding.
All dimensions to interior/exterior walls indicated are to
face of stud wall or concete/c.m.u. unless noted otherwise.
Copyright Note:
Meyer and Meyer Inc., expressly reserves the Common
Law Copyrights and other Property Rights in these plans.
These drawings are the property of Meyer and Meyer Inc.,
and shall not to be reproduced in any manner, nor are they
to be assigned to any third party without first obtaining the
expressed written permission and consent of Meyer and
Meyer Inc.
Project:File Location: L:\Titleblocks\24x36Titleblock-New.dwgMEYER & MEYER
ARCHITECTURE AND INTERIORS
T: 617.266.0555
F: 617.266.2952
396 Commonwealth Avenue
Boston, Massachusetts 02215
Summer Street
Realty Trust
46 Summer Street,
Yarmouth Port, MA
A2.00
Exterior
Elevations
##########
Checker
Ryota Uchida
Design Development August 28, 2024
1/4" = 1'-0"
1 Proposed West Elevation
1/4" = 1'-0"
2 Existing West Elevation
1/4" = 1'-0"
3 Proposed South Elevation
1/4" = 1'-0"
4 Existing South Elevation
First Floor
0' -0"
B.O. Ceiling Joists
7' -11 9/16"
Ridge Height
17' -2"
Replace Rake Trims
Replace Door & Trims
Replace Existing Window w/
New Trims
Replace Window w/
New Trims
First Floor
0' -0"
B.O. Ceiling Joists
7' -11 9/16"
Ridge Height
17' -2"
First Floor
0' -0"
B.O. Ceiling Joists
7' -11 9/16"
Ridge Height
17' -2"
Replace Existing Asphalt Shingle w/
Cedar Roof Shingle
Replace Eave/ Rake Trims
Replace Gutter
Existing Doors to Remain
First Floor
0' -0"
B.O. Ceiling Joists
7' -11 9/16"
Ridge Height
17' -2"
Drawing Number:
Checked:
Project Number:
Drawn:
Registration:
Issue Dates and Revisions:
Drawing Title:
General Notes:
General Contractor shall make all Subcontractors and
Suppliers aware of the requirements of these notes.
All work shall be performed in compliance with all
applicable Local, State and National Building, Life Safety
and Electrical Codes.
General Contractor shall be responsible for securing all
permits as necessary for the completion of work shown
throughout the Contract Documents.
General Contractor shall lay out in the field the entire
work to verify dimensional relationships before
constructing any part, and shall verify all existing
conditions and locations before proceeding.
Failure to verify dimensions and conditions before
proceeding may subject the General Contractor to the
required removal of completed work at General Contractor
cost, if a discrepancy which could have been discovered
causes modifications to the plans.
General Contractor shall coordinate the dimensional
requirements between the work of the various trades.
Any discrepancies found in the plans, dimensions, existing
conditions or any apparent error in the classifying or
specifying of a product, material or means of assembly is
to be pointed out to the Architect immediately.
Drawings shall not be scaled for dimensions and/or sizes.
Owner and Architect assume no responsibility for use of
incorrect scale.
Regardless of whether or not an item is shown or
specified, General Contractor shall provide said item if it
is necessary for the proper installation or function of an
item shown or specified. Suppliers and Subcontractors
shall inform the General Contractor of their requirements
for the work of other trades, which may not be indicated,
prior to bidding.
All dimensions to interior/exterior walls indicated are to
face of stud wall or concete/c.m.u. unless noted otherwise.
Copyright Note:
Meyer and Meyer Inc., expressly reserves the Common
Law Copyrights and other Property Rights in these plans.
These drawings are the property of Meyer and Meyer Inc.,
and shall not to be reproduced in any manner, nor are they
to be assigned to any third party without first obtaining the
expressed written permission and consent of Meyer and
Meyer Inc.
Project:File Location: L:\Titleblocks\24x36Titleblock-New.dwgMEYER & MEYER
ARCHITECTURE AND INTERIORS
T: 617.266.0555
F: 617.266.2952
396 Commonwealth Avenue
Boston, Massachusetts 02215
Summer Street
Realty Trust
46 Summer Street,
Yarmouth Port, MA
A2.01
Exterior
Elevations
##########
Checker
Ryota Uchida
Design Development August 28, 2024
1/4" = 1'-0"
1 Proposed East Elevation
1/4" = 1'-0"
2 Existing East Elevation
1/4" = 1'-0"
3 Proposed North Elevation
1/4" = 1'-0"
4 Existing North Elevation