HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. Lot ?`/- I u o Zone of Contribution: In Out Acreage
Commercial: Residential: ,/
Street: 37 a h�t r
Village: t_), /, Floor Plan: #Bedrooms:
Owner: Ca r(a5 ,�f -7 M 1 j Installer: rig, ILL ,� ,
Address: ;o9S Aro►� C± £L 1- , - Phone: cbg- a?y-Y �,
?S3
Phone:
Builder: Engineer: P To c-Eve-lee
Address: Phone: SUS- ' '? 7. 5- 3 i 3
Phone:
N/A YES NO
1.Required#of copies received IZ
2.Date of soils exam and percolation test not older than 2 years V
3. 4-5 ft of naturally occurring pervious material,above water table V
4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: (/
5.Water line 10 ft from septic components Var.: ✓
6. Benchmark indicated and shown-NGVD if near wetlands (/
7. Septic tank minimum 10 ft from foundation,deck Var.: ,/
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: ✓
9. Leaching minimum 100 ft from wetlands Var.: V
10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: ,/
11.Tank/leaching minimum 10 ft from property line Var.: ✓
12. System meets all other setback requirements Var.:
13.Uses adjustment for maximum high groundwater Var.: ✓
14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.: V
15. System not in top or subsoil(A,B horizons)or 5' removal L/
16.Proposed contours are suitable ✓
17. System meets slope requirements-min. 1/8", ''/a"preferred / V
18. System meets breakout requirements PVC liner: iy Wall:
19. Specified tee sizes are proper, gas baffle on outlet tee ✓
20. Sewage is under 10,000 gpd for parcel
21.No garbage disposal ✓
22. System adequately sized for its intended use ,/
23.Minimum 6"stone or compacted below tank and dbox Z
24.Manhole covers within 6"of grade,pump chamber cover to grade L/
25.Inspection port on plastic chambers/leach field ,/
26. Electrical permit for pump chamber/Separate meter for duplexes L/
27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size ✓
28. Septic tank/pump chamber to be factory waterproofed ✓
29.Vent provided if leaching below 3 feet,under driveway/parking ,/
30. Buoyancy calculations for tank/pump chamber V
31. Engineer to inspect and certify soils: wall: commercial: V
32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature V _
33.H-20 loading is subject to vehicular traffic,groundwater v
34.Title V Application and permit fee,installer signature
35. Foundation footing min. 2 feet above adjusted ground water for new house ✓ /
36.Deed Restriction required max. #bedrooms: max. flow: gpd / ✓
37. Check area lots for groundwater/Label groundw "n sessor's Map
Plan reviewed by: d a t( I 6/03/03