Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. Lot one of Contribution: In Out Acreage Commercial: ✓ Residential: Street: r' 1 �S le+ . 6 Village: ( .p rloor Plan: yer # Bedrooms: Owner: 5,,,.. 1 e4e_riovN ' 'nstaller: ClAc, - ,\ - /2 1vc.✓V/ Address: S t•,,A q r._;f Ad Phone: 'cz)5c-- 3 5 Y -.c),a J b Phone: ( 7 -o?44y- 5-5-31 Builder: ;?ngineer: 0( ) r C kpe Address: Phone: S7_,sr - 3 G a - y5-L// Phone: N/A YES NO 1. Required# of copies received 2. Date of soils exam and percolation test not older than 2 years v' 3. 4-5 ft of naturally occurring pervious material, above water table 4. Foundation 2 ft above high point of road H.P.: Fnd: Var.: / 5. Water line 10 ft from septic components N ar.: 6. Benchmark indicated and shown-NGVD if near wetlands / 7. Septic tank minimum 10 ft from foundation, deck Var.: 8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 9. Leaching minimum 100 ft from wetlands Var.: 10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: 11. Tank/leaching minimum 10 ft from property line Var.: 12. System meets all other setback requirements Var.: 13. Uses adjustment for maximum high groundwater Var.: 14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.: 15. System not in top or subsoil (A,B horizons)or 5' removal k 16. Proposed contours are suitable 17. System meets slope requirements-min. 1/8", '/a"preferred 18. System meets breakout requirements PVC liner: Wall: v 19. Specified tee sizes are proper, gas baffle on outlet tee _ t/ 20. Sewage is under 10,000 gpd for parcel ✓ 21.No garbage disposal 22. System adequately sized for its intended use v 23. Minimum 6"stone or compacted below tank and dbox17 V 24. Manhole covers within 6"of grade, pump chamber col er to grade 25. Inspection port on plastic chambers/leach field 26. Electrical permit for pump chamber/Separate meter foi duplexes v 27. Pump system -2" line,weep hole,check valve,tee in dbox, pump size 28. Septic tank/pump chamber to be factory waterproofed 29. Vent provided if leachin. below 3 feet, under drivewai /parking 30. Buoyancy calculations for tank/pump chamber ✓ 31. Engineer to inspect and certify soils: wall: commercial: 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature ✓ 33. H-20 loading is subject to vehicular traffic, groundwater 34. Title V Application and permit fee, installer signature 35. Foundation footing min. 2 feet above adjusted ground water for new house ,..7 36. Deed Restriction required max. #bedroom: max. flow: 37. Check area lots for groundwater/Label groundwater in 1.ssessor's Map gpd Plan reviewed by: `A(/((dad'/ 6/03/03