HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. Lot 3-5/$Ll Zone of Contribution: In Out ✓Acreage
//�'�f Commercial: Residential: ✓
Street: '�c/f c1
Village: S y Floor Plan: #Bedrooms:
Owner: L cn kA4rk �¢l"W tc� Installer: GLG,, a(- -11,ew
Address: '- ,3/4,,,,3/4,,, A/c Phone: 77/- 02-3�/- ar
/'-f (
Phone:
Builder: Engineer: l?e y-e ,)�.-..S lAn c.
Address: Phone: 5-13 k- 36 0 -3 3//
Phone:
N/A YES NO
1. Required#of copies received _ /
2.Date of soils exam and percolation test not older than 2 years t/
3. 4-5 ft of naturally occurring pervious material,above water table v
4. Foundation 2 ft above high point of road H.P.: Fnd: Var.: ✓
5.Water line 10 ft from septic components Var.: V
6. Benchmark indicated and shown-NGVD if near wetlands v
7. Septic tank minimum 10 ft from foundation, deck Var.: ✓
8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 090->l"/.1"' ,/
9. Leaching minimum 100 ft from wetlands Var.: ✓
10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: ✓
11. Tank/leaching minimum 10 ft from property line Var.: v
12. System meets all other setback requirements Var.: v
13. Uses adjustment for maximum high groundwater Var.: ✓
14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.: ✓
15. System not in top or subsoil(A,B horizons)or 5' removal v
16. Proposed contours are suitable V
17. System meets slope requirements-min. 1/8", '/"preferred ✓
18. System meets breakout requirements PVC liner: Wall: V
19. Specified tee sizes are proper, gas baffle on outlet tee ✓
20. Sewage is under 10,000 gpd for parcel ✓
21.No garbage disposal ✓
22. System adequately sized for its intended use `/
23.Minimum 6"stone or compacted below tank and dbox V
24.Manhole covers within 6"of grade,pump chamber cover to grade
25. pectio onplastic chambers/leach field 1./
26. ectrical ermit r pump chamber/Separate meter for duplexes V
27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size V
28. Septic tank/pump chamber to be factory waterproofed V
29.Vent provided if leaching below 3 feet,under driveway/parking 1/
30.Buoyancy calculations for tank/pump chamber ✓
31. Engineer to inspect and certify soils: wall: commercial: ✓
32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature
33. H-20 loading is subject to vehicular traffic, groundwater ✓
34. Title V Application and permit fee,installer signature ✓✓
35. Foundation footing min. 2 feet above adjusted ground water for new house
36.Deed Restriction required max. #bedrooms: max. flow: gpd
37. Check area lots for groundwater/Label groundwater' or's Map
Plan reviewed by: '-b//•.0`( ( 6/03/03