Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. Lot 3-5/$Ll Zone of Contribution: In Out ✓Acreage //�'�f Commercial: Residential: ✓ Street: '�c/f c1 Village: S y Floor Plan: #Bedrooms: Owner: L cn kA4rk �¢l"W tc� Installer: GLG,, a(- -11,ew Address: '- ,3/4,,,,3/4,,, A/c Phone: 77/- 02-3�/- ar /'-f ( Phone: Builder: Engineer: l?e y-e ,)�.-..S lAn c. Address: Phone: 5-13 k- 36 0 -3 3// Phone: N/A YES NO 1. Required#of copies received _ / 2.Date of soils exam and percolation test not older than 2 years t/ 3. 4-5 ft of naturally occurring pervious material,above water table v 4. Foundation 2 ft above high point of road H.P.: Fnd: Var.: ✓ 5.Water line 10 ft from septic components Var.: V 6. Benchmark indicated and shown-NGVD if near wetlands v 7. Septic tank minimum 10 ft from foundation, deck Var.: ✓ 8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 090->l"/.1"' ,/ 9. Leaching minimum 100 ft from wetlands Var.: ✓ 10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: ✓ 11. Tank/leaching minimum 10 ft from property line Var.: v 12. System meets all other setback requirements Var.: v 13. Uses adjustment for maximum high groundwater Var.: ✓ 14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.: ✓ 15. System not in top or subsoil(A,B horizons)or 5' removal v 16. Proposed contours are suitable V 17. System meets slope requirements-min. 1/8", '/"preferred ✓ 18. System meets breakout requirements PVC liner: Wall: V 19. Specified tee sizes are proper, gas baffle on outlet tee ✓ 20. Sewage is under 10,000 gpd for parcel ✓ 21.No garbage disposal ✓ 22. System adequately sized for its intended use `/ 23.Minimum 6"stone or compacted below tank and dbox V 24.Manhole covers within 6"of grade,pump chamber cover to grade 25. pectio onplastic chambers/leach field 1./ 26. ectrical ermit r pump chamber/Separate meter for duplexes V 27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size V 28. Septic tank/pump chamber to be factory waterproofed V 29.Vent provided if leaching below 3 feet,under driveway/parking 1/ 30.Buoyancy calculations for tank/pump chamber ✓ 31. Engineer to inspect and certify soils: wall: commercial: ✓ 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature 33. H-20 loading is subject to vehicular traffic, groundwater ✓ 34. Title V Application and permit fee,installer signature ✓✓ 35. Foundation footing min. 2 feet above adjusted ground water for new house 36.Deed Restriction required max. #bedrooms: max. flow: gpd 37. Check area lots for groundwater/Label groundwater' or's Map Plan reviewed by: '-b//•.0`( ( 6/03/03