Loading...
HomeMy WebLinkAboutEngineer PlanPARCEL ID: 41 /28.1 14 EXIST. LEACHING TOP CONC BH CORN. ,� .,> i. lI+. i7 PARCEL ID: 41 /28.2 LEGEND ^' PARCEL ID: 41 /27 6 PROPOSED CONTOUR $2 ® PROPOSED SPOT GRADE L T 106 --98 -- EXISTING CONTOUR "' w 6611 A 12,430 S.F.f + 96.52 EXISTING SPOT GRADE •� Y N ( .29 AC. +) EXISTING WATER SERVICE •„ ,y 14 TEST PIT ""J• •" s w. ++ d w u n `- ss � N em] ] '� a, '� ] ' • H M WOODS '• ] n [LOCUS 4 INFORMATION ,I u _-----CB/DH 11 SURVEY REFERENCE: (BK 192/PG 105) (fnd) J 0 0 EXISIINLUN G 3BR DWE 16 41 TOF. EL. i�Fl•�ia - T O o_ PARCEL ID: m 41 /30 l CA rn PLAN OF LAND IN SOUTH YARMOU I FOR EMMANUEL DITIBERIOj— BY THOMAS E. KELLEY, PLS, DATED MARCH 27, 1965 Department RECEIVED SEP 2 7 2024 HEALTH DEPT. GRAPHIC SCALE 0 20 40 60 ( IN FEET ) 1 inch = 20ft. PARCEL ID: MAP 041 PAR. 029 TITLE REF: 36316/023 PLAN REF: 192/105(sh 1) PROPERTY NOT IN ZONE II PROPERTY NOT MADEP NIT. SENSITIVE AREA FLOOD ZONE: "X" (0.2%) COMMUNITY PANEL: 25001C-0589—J DATED:07/16/14 SEPTIC SYSTEM REPAIR PLAN LOCATED AT: 12 HEMLOCK PATH SOUTH YARMOUTH, MA PREPARED FOR MEGHAN & KEN CLEMENTS/ SEPTEMBER 26, 2024 ,, MEYER & SONS, INC. P.O. BOX 981 EAST SANDWICH, MA. 02537 PH: (508)360-3311 FAX: (774)413-9468 meyerandsonstitle5®gmail.com SHEET 1 OF 2 ELEV. TOP FOUNDATION: (Existing) EL. = 16.41 EXISTING OUTLET NOTE: PLACE MAGNETIC MARKING TAPE OVER ALL COVERS BRING ALL COVERS TO WITHIN 3" OF FINISH GRADE 14.4 � F.G.EL: 14.61 INV: 12.35 10, TEE'S ARE TO BE 4" SCH 40 PVC GAS BAFFLE F.G. EL: 14.0 FINISHED GRADE (14.0 MAX) MAINTAIN 2% MIN SLOPE OVER LEACHING AREA 2" OF 3/8" DOUBLE WASHED STONE OR FILTER FABRIC 4" SCH 40 PVC ® S= 1% (MIN. INV. 11.40 0.96 FF. D INV. 12.10 INV. 11.20 EXIST. 1,500 GALLON SEPTIC TANK GAS BAFFLE TO BE INSTALLED ON OUTLET TEE AS MANUFACTURED BY TUF-TITE, ZABEL, OR EQUAL NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INVERTS PRIOR TO CONSTRUCTION 2) D-BOX SHALL BE SET LEVEL AND TRUE TO GRADE ON A MECHANICALL COMPACTED SIX INCH CRUSHED STONE BASE, AS SPECIFIED IN 310 CMR 15.221(2) 3) INSTALL INLET & OUTLET TEES AS REQUIRED SEPTIC SYSTEM PROFILE SOIL LOGS DATE: SEPTEMBER 11, 2024 SOIL EVALUATOR: DARREN M MEYER, IRS, CSE WITNESS: BARRY LEWIS, YARMOUTH HEALTH DEPT. Elev. TP- 1 Depth 13.88 0" FILL 12.72 14" A LOAMY SAND 12.05 IOYR 4/1 22" B LOAMY SAND 1OYR 5/8 10.55 40" (. MEDIUM SAND 7.88 2.5Y 6/4 72" C2 COARSE SAND 2.38 2.5Y 7/4 138" PERC RATE <2 MIN/IN. ("CRC2' HORIZON) NO GROUNDWATER OBSERVED WELL: MIW-29, ZONE A, LEVEL 8.67, ADJ: 2.0 TT USE EL 4.38 FOR "GROUNDWATER ELEV.' • I, Dacron M Meyer, CSE, hereby certify that I am currently approved by MADEP pursuant to 310 CMR 15.017 to conduct soft evaluations and that the above analysis has been performed by me consistent with the requirements of 310 CMR 15.017. 1 further certify that I have possed the Soil Eval. Exam. PROPOSED DB-3 DISTRIBUTION BOX (H20) INV. ELEV.= 10.50 ®®® ®®® ®®® 4' / 1 3 X 8' 3/4" - 1_1/2" DOUBLE WASHED STONE 0 / EFFECTIVE LENGTH = 32' 1 TOP CONC. ELEV.= 11.04 INV. ELEV.= 10.50 _ BOTTOM EL.= 9.54 SEPARATION 5.16 FT. 4' 1 4 FT. BREAKOUT ELEV.= 11.04 4' EFFECTIVE WIDTH = 12' 1 ADJ. GROUNDWATER" EL: 4.38 -1- SOIL ABSORPTION SYSTEM (SECTION (FLOW DIFFUSOR) GENERAL NOTES: 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V. AND ANY APPLICABLE LOCAL RULES AND REGULATIONS. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. S. ALL ELEVATIONS BASED ON ASSUMED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY TOWN WATER. 8. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR. 9. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. 10. EXISTING LEACHING TO BE PUMPED, CRUSHED AND REMOVED PER TITLE 5 REPLACE WITH CLEAN MEDIUM SAND PER TITLE 5 SPECS. 11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION 12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY 13. NO PRIVATE ABUTTING WELLS WITHIN 150' OF PROPOSED LEACHING. 14. NO WETLANDS WITHIN 100' OF PROPOSED LEACHING. 15. ALL PIPING TO BE 4" SCH 40 0 1/8-/FT (UNLESS SPECIFIED) DESIGN CRITERIA NUMBER OF BEDROOMS: 3 BEDROOM DESIGN SOIL TEXTURAL CLASS: CLASS 1 (0.74 GPD/SF) DESIGN PERCOLATION RATE: <2 MIN/IN DAILY FLOW: 110 G.P.D. X 3 BR = 330 G.P.D. GARBAGE GRINDER: NO (not designed for garbage grinder) SEPTIC TANK: 330 gpd x 200% = 660 gpd, USE EXIST. 1,500 GAL. SEPTIC TANK LEACHING AREA REQUIRED: (330)/0.74 = 445.94 S.F. USE THREE (3) FLOW DIFFUSORS (8x4x0.96') W/ 4' STONE ON ALL SIDES: 32' L x 12' W x 0.96'D BOTTOM AREA: 32 x 12 = 384 SF SIDE AREA: (32 + 12) X 2 X 0.96 = 84.48 SF TOTAL SQUARE FEET PROVIDED = 468.8 vs. 445.94 REQ'D DESIGN FLOW PROVIDED: 0.74(468.8 S.F.) = 346.9 G.P.D. vs. 330 G.P.D. req'd PROPOSED SEPTIC SYSTEM UPGRADE PLAN 12 HEMLOCK PATH, SOUTH YARMOUTH, MA Prepared for: Clements/Ready Rooter Exc. Design and Site Plan by: I SCALE DRAWN DATE MEYER & SONS, INC. N.T.S. DMM 09/26/24 PO BOX 981 EASTSANOWICH, AM 02537 REV DATE CHECKED SHEET NO. 508362-2922 DMM 2 of 2