HomeMy WebLinkAbout62 Silver Leaf Lane inspection reportTown of Yarmouth, MA
Inspection Report
Inspection: Inspection
Inspector: Debra Bruinooge
Inspection Date: Oct 10, 2024
Record: Rental Registration #BHR-24-840
Location: 62 SILVER LEAF LN, WEST YARMOUTH, MA 02673
Applicant: Henry Ward
Rental Inspection
Overall Result: Pass
Overall Remarks:
Year-Round Rental. Met with owner's representative for the
inspection. New tenants were in the process of moving in and
are occupying the entire home. Property has 3 bedrooms on
main floor and a permitted basement apartment with 2
bedrooms in the basement. Home was ready for occupancy
with minor findings. Please see below for details. David, the
caretaker, will send pictures of areas identified before rental
certificate will be issued. *Update: Pictures received
10/10/2024
Checklist:
1.
Number of Bedrooms
Result: Pass
Remarks:
#1 11.490 X 11625 #2 13.560 X 17.055 #3 11.475 X 13.435 #1
10.390 X 15.150 (basement) #2 10.090 X 15.065 (basement)
2.
Maximum Occupancy: Based on septic system capacity,
number of bedrooms and bedroom square footage
Result: Pass
Remarks:
5 bedrooms total/550 GPD septic system-Maximum
Occupancy-10
3.
Basement
Result: Pass
Remarks:
Mostly finished (See Yarmouth BOA #4960)
4.
Electrical Panel
Result: Pass
Remarks:
2 both good and well labeled
5.
Copy of Tenant's Legal Rights have been issued to tenant.
Result: Pass
Remarks:
Gave to new tenants with my business card
105CMR 410.00 0Minimum Standards of Fitness
for Human Habitation
(State Sanitary Code: Chapter II)
Result: Pass
410.100 Kitchen Facilities
*
Result: Pass
410.110 Bathroom Facilities : Sinks, Toilets, Tubs
& Showers
*
Result: Pass
410.120 Approved Toilets
*
Result: Pass
410.130 Water supply
Potable Water/Sanitary Drainage
Result: Pass
410.140 Plumbing Connections
*
Result: Pass
410.150 Hot Water
110-130 °F for faucets & 110-120 °F for bathtubs a & showers
Result: Pass
410.160 Heating Systems
*
Result: Pass
410.170 Venting
*
Result: Pass
410.180 Temperature Requirements
Owner shall proved heat in every habitable room & every room
containing a toilet, shower or bathtub from September 15th
through May 31st. 64° from 11:01 pm to 6:59 am 68° from 7 am
to 11:00 pm
Result: Pass
410.200 Provision and Metering of Electrical or
Gas
*
Result: Pass
410.210 Provision of Oil
*
Result: Skip
410.220 Natural and Mechanical Ventilation
*
Result: Pass
410.230 Owner's Laundering Responsibilities
If owner provides bed linens, towels, pillows or mattress
Result: Skip
410.235 Owner's Installation, Maintenance and
Repair Responsibilities
*
Result: Pass
410.240 Occupant's Installation and
Maintenance Responsibilities
*
Result: Skip
410.250 Asbestos-containing Material
*
Result: Pass
410.260 Means of Egress
*
Result: Pass
410.270 Locks
*
Result: Pass
410.300 Electrical Supply & Illumination
*
Result: Pass
410.310 Auxiliary Emergency Lighting Systems
& Exit Signs
For properties with 10 or more units
Result: Skip
410.320 Electrical Service
Temporary Wiring, Amperage
Result: Pass
410.330 Smoke Detector and Carbon Monoxide
Alarms
*
Result: Pass
Remarks:
Present as required. Tested and working.
410.400 Owner/Manager Contact Information
and Notice of Occupants' Legal Rights and
Responsibilities
Contact information and postings inside and outside of home
Result: Pass
410.410 Building Identification
*
Result: Pass
410.420
Habitability Requirements
Result: Pass
410.430 Natural Light and Obstructions
*
Result: Pass
410.470 Lead-based Paint Hazards in Residence
*
Result: Pass
410.500 Owner Responsibility to Maintain
Building & Structural Elements
*
Result: Fail
Remarks:
-Rot on sills @sunroom-roof replaced in 2024, which fixed
drainage, but rot not repaired at this time but it will be. -Rot on
rake boards @ sunroom
410.510 Occupant 's Responsibility Regarding
Building and Structural Elements
*
Result: Skip
410.520 Protective Railings and Walls
*
Result: Pass
410.530 Weather-tight elements
*
Result: Pass
410.540 Installation of Screens
*
Result: Fail
Remarks:
Missing exterior door screens. (A) The owner shall provide and
install screens for exterior openable windows so that: (1) They
are in place during the period from April 1st through October
31st in each year; (2) They are no less than 16 mesh per square
inch; (3) They cover that part of the window designed to be
opened, except in double hung windows where half screens
shall meet this requirement; and (4) They are tight fitting and
prevent the entrance of pests. (B) Expandable, temporary
screens shall not satisfy the requirements of 105 CMR
410.540(A). (C) The owner shall provide and install screen
doors for all doorways opening directly to the outside from any
dwelling unit or rooming unit where the screen doors will be
permitted to slide to the side or open in an outward direction
so that: (1) They are in place during the period from April 1st
through October 31st in each year; (2) They are 16 mesh per
square inch; (3) They are equipped with a self-closing device
except where the screen is designed to open to the side; and
(4) They are tight fitting and prevent the entrance of pests. (D)
105 CMR 410.540(C) shall not apply to homeless shelters.
410.550 Elimination of Pests
Owners & Occupants are responsible for the control &
elimination of pests
Result: Pass
Remarks:
None observed
410.560 Refuse
*
Result: Pass
Remarks:
Tenant responsible for trash-using paid pick up Owner
responsible for landscaping.
410.570 Maintenance of Areas in a Sanitary and
Safe Condition
*
Result: Pass
410.620 Conduct of Inspections
The need for an additional inspection by a specialized inspector
pursuant to 105 CMR 410.620(A) and the reason that such
inspection is necessary
Result: Pass
410.630 Conditions Deemed to Endanger or
Materially Impair Health and Safety
One or more of the violations cited on this report may materially
impair the health or safety and/or well-being of any person(s)
occupying the premises
Result: Pass
780 CMR 111.5.1 Posting of Use & Occupancy
STR Only
Result: Skip
780 CMR 111.5.2 Required Egress posting
STR Only
Result: Skip
780 CMR Means of Egress
STR Only
Result: Skip
780 CMR R314 & R315 Smoke/CO/Heat
STR Only
Result: Skip
R314 & R315 Smoke/CO/Heat Detectors
STR Only
Result: Skip
This inspection report is signed and certified
under the pains and penalties of perjury.
Inspector's signature and date
Result: Pass
Remarks:
Debra Bruinooge-10/02/2024 &10/10/2024-2:30PM