HomeMy WebLinkAbout27 Anchorage Lane inspection reportTown of Yarmouth, MA
Inspection Report
Inspection: Inspection
Inspector: Debra Bruinooge
Inspection Date: Dec 5, 2024
Record: Rental Registration #BHR-24-862
Location: 27 &29 ANCHORAGE LN, WEST
YARMOUTH, MA 02673
Applicant: Eleni Kontis
Rental Inspection
Overall Result: Pass
Overall Remarks:
#27 Met with owners Eleni and Jon along with the
occupants of 2 years for the inspection. This
inspection is for both the follow-up from Sept
2023 and 2024/2025 year. Home was found
overall, neat, clean and organized. All outstanding
issues from 2023 have been appropriately
addressed. Only item identified in this inspection
is the weather stripping on storm door at front.
Please see below. Owner will send photo when
repaired.
Checklist:
1.
Number of Bedrooms/Measurements
Result: Pass
Remarks:
#1 10.485 X 11.485 #2 10.880 X 10.635
2.
Maximum Occupancy: Based on septic system
capacity, number of bedrooms and bedroom
square footage
Result: Pass
Remarks:
4
3.
Basement
Result: Pass
Remarks:
None
4.
Electrical Panel
Result: Pass
Remarks:
Ok
5.
Copy of Tenant's Legal Rights have been issued to
tenant.
Result: Pass
105CMR 410.00 0Minimum Standards
of Fitness for Human Habitation
(State Sanitary Code: Chapter II)
Result: Pass
410.100 Kitchen Facilities
*
Result: Pass
410.110 Bathroom Facilities : Sinks,
Toilets, Tubs & Showers
*
Result: Pass
410.120 Approved Toilets
*
Result: Pass
410.130 Water supply
Potable Water/Sanitary Drainage
Result: Pass
410.140 Plumbing Connections
*
Result: Pass
410.150 Hot Water
110-130 °F for faucets & 110-120 °F for bathtubs a &
showers
Result: Pass
410.160 Heating Systems
*
Result: Pass
410.170 Venting
*
Result: Pass
410.180 Temperature Requirements
Owner shall proved heat in every habitable room &
every room containing a toilet, shower or bathtub
from September 15th through May 31st. 64° from
11:01 pm to 6:59 am 68° from 7 am to 11:00 pm
Result: Pass
410.200 Provision and Metering of
Electrical or Gas
*
Result: Pass
410.210 Provision of Oil
*
Result: Skip
410.220 Natural and Mechanical
Ventilation
*
Result: Pass
410.230 Owner's Laundering
Responsibilities
If owner provides bed linens, towels, pillows or
mattress
Result: Skip
410.235 Owner's Installation,
Maintenance and Repair
Responsibilities
*
Result: Fail
Remarks:
-storm door at front requires repair to ensure that
it is weathertight See also 410.530
410.240 Occupant's Installation and
Maintenance Responsibilities
*
Result: Pass
410.250 Asbestos-containing Material
*
Result: Pass
410.260 Means of Egress
*
Result: Pass
410.270 Locks
*
Result: Pass
410.300 Electrical Supply &
Illumination
*
Result: Pass
410.310 Auxiliary Emergency Lighting
Systems & Exit Signs
For properties with 10 or more units
Result: Skip
410.320 Electrical Service
Temporary Wiring, Amperage
Result: Pass
410.330 Smoke Detector and Carbon
Monoxide Alarms
*
Result: Pass
Remarks:
New smoke detectors installed. Present as
required. Tested and working.
410.400 Owner/Manager Contact
Information and Notice of Occupants'
Legal Rights and Responsibilities
Contact information and postings inside and
outside of home
Result: Pass
410.410 Building Identification
*
Result: Pass
Remarks:
New numbers put up for better identification for
first responders.
410.420
Habitability Requirements
Result: Pass
410.430 Natural Light and
Obstructions
*
Result: Pass
410.470 Lead-based Paint Hazards in
Residence
*
Result: Pass
410.500 Owner Responsibility to
Maintain Building & Structural
Elements
*
Result: Pass
410.510 Occupant 's Responsibility
Regarding Building and Structural
Elements
*
Result: Pass
410.520 Protective Railings and Walls
*
Result: Pass
410.530 Weather-tight elements
*
Result: Fail
Remarks:
-Storm door at front is not weathertight-repair (B)
A door leading from a residence or dwelling unit to
the exterior shall be considered to be
weathertight only if: (1) All panes of glass are in
place, unbroken and properly sealed; (2) The door
opens and closes fully without excessive effort;
and (3) One of the following conditions is met: (a)
The door is sufficiently well-fitted so that it
minimizes the infiltration of air or moisture and
the space between the door and the prime door
frame is no larger than c inch at any point on the
sides of the door; or (b) storm door is affixed to
the prime door frame in such a way as to
minimize the infiltration of air or moisture.
410.540 Installation of Screens
*
Result: Pass
Remarks:
*The screen on the rear storm should be repaired
or replaced by 4/1 (A) The owner shall provide
and install screens for exterior openable windows
so that: (1) They are in place during the period
from April 1st through October 31st in each year;
(2) They are no less than 16 mesh per square
inch; (3) They cover that part of the window
designed to be opened, except in double hung
windows where half screens shall meet this
requirement; and (4) They are tight fitting and
prevent the entrance of pests. (B) Expandable,
temporary screens shall not satisfy the
requirements of 105 CMR 410.540(A). (C) The
owner shall provide and install screen doors for all
doorways opening directly to the outside from
any dwelling unit or rooming unit where the
screen doors will be permitted to slide to the side
or open in an outward direction so that: (1) They
are in place during the period from April 1st
through October 31st in each year; (2) They are 16
mesh per square inch; (3) They are equipped with
a self-closing device except where the screen is
designed to open to the side; and (4) They are
tight fitting and prevent the entrance of pests.
410.550 Elimination of Pests
Owners & Occupants are responsible for the control
& elimination of pests
Result: Pass
Remarks:
None observed
410.560 Refuse
*
Result: Pass
Remarks:
Occupant responsible
410.570 Maintenance of Areas in a
Sanitary and Safe Condition
*
Result: Pass
410.620 Conduct of Inspections
The need for an additional inspection by a
specialized inspector pursuant to 105 CMR
410.620(A) and the reason that such inspection is
necessary
Result: Skip
410.630 Conditions Deemed to
Endanger or Materially Impair Health
and Safety
One or more of the violations cited on this report
may materially impair the health or safety and/or
well-being of any person(s) occupying the premises
Result: Pass
780 CMR 111.5.1 Posting of Use &
Occupancy
STR Only
Result: Skip
780 CMR 111.5.2 Required Egress
posting
STR Only
Result: Skip
780 CMR Means of Egress
STR Only
Result: Skip
780 CMR R314 & R315
Smoke/CO/Heat
STR Only
Result: Skip
R314 & R315 Smoke/CO/Heat
Detectors
STR Only
Result: Skip
This inspection report is signed and
certified under the pains and penalties
of perjury.
Inspector's signature, date and time
Result: Pass
Remarks:
Debra Bruinooge-12/05/2024-2:00PM