HomeMy WebLinkAbout5154 1 Windswept Path Elevations 14' x 26' Pool14' x 26' PoolNWSEGENERAL NOTES:TITLEA2 RECTANGLEDESCRIPTIONPAGE1 OF 4DATE04/12/2023SCALE 1/4 inch = 1 foot.18" x 24" PAPERDESIGNLAYOUTPIPINGSTRUCTURALELECTRICALSPECIFICATIONSDETAILSEQUIPMENTNOTE; SOME INSTALLATIONS MAYREQUIRE A SITE SPECIFIC SITE PLAN ANDA SEAL BY A PROFESSIONAL ENGINEER.NOTE:INSTALLATION IS TO BE DONE IN ACCORDANCEWITH ALL FEDERAL, STATE AND LOCALBUILDING CODES INCLUDINGANSI/NSPI 3, ANSI/NSPI 5, ANSI/APSP 7,ANSI/APSP/ICC 15THIS PLAN MAY REQUIRE MODIFICATIONS DUETO SOIL CONDITIONS, SLOPES, RETAININGWALLS, ADJACENT STRUCTURES, LOCATIONAND FEATURESDESIGN364 sq.ftDepth3'8" to 7'Perimeter80 ft.AreaGallons16,000FEATURES; L.E.D. LIGHTINGSCALE 1/4 inch = 1 foot.18" x 24" PAPERA2 RECTANGLE 14' x 26'
26 ft.14 ft.3'-8"DeepINDICATE HERE DISTANCE FROMPOOL WATERLINE TO PROPERTY LINEPROPERTY LINEPROPERTY LINERESIDENCEINDICATE HERE DISTANCE FROMPOOL WATERLINE TO PROPERTY LINEINDICATE HERE DISTANCE FROMPOOL WATERLINE TO PROPERTY LINEINDICATE HERE DISTANCE FROMPOOL WATERLINE TO RESIDENCE7'Deep1 ft.ALL DIMENSIONS ARE TAKEN TOWATERLINENOTES:BEFORE EXCAVATION:CHECK FOR UNDERGROUND UTILITIES,PIPES, WIRES, ETC.SEE SETBACK AND EASEMENTREQUIREMENTSPROPERTY LINE
LOCATE AND PROVIDE ALL POOL PENETRATIONS PRIOR TOGUNITE:MAIN DRAINSSKIMMERSRETURNSVAC. LINEWATER FEATURESLIGHTSETCPAGELAYOUTDATE04/12/2023SCALE 1/4 inch = 1 foot.18" x 24" PAPERCRITICAL;DO NOT ALLOW ANY CONSTRUCTION TO TAKE PLACE INTO ANYEASEMENT.CONFIRM MINIMUM PROPERTY LINE SETBACK REQUIREMENTS FORPOOL CONSTRUCTION ON YOUR PROPERTY ANDDO NOT ALLOW ANY CONSTRUCTION TO TAKE PLACE INTO SETBACKS.POOL LAYOUT PAGESITE PLANLAYOUT SCALE 1/4 inch = 1 footPROVIDE FENCE ENCLOSURE MINIMUM 4' HIGH, NON-CLIMBABLE W/ SELF CLOSING/ SELF LATCHING GATESPROVIDE LANDSCAPE BARRIER AROUND POOLEQUIPMENTPROVIDE DOOR ALARM, POOL ALARM OR SAFETY FENCEAROUND POOLPRIOR TO EXCAVATION, CONFIRM THERE ARE NOUNDERGROUND CABLES, PIPES, LINES OR UTILITIES IN THEPOOL AREA.POOL WATER MUST BE 10' MINIMUM HORIZONTAL DISTANCE FROMANY OVERHEAD POWERLINES.Note:Installation is to be done in accordance with all Federal,state and local building codes including IRC 2015 as wellas compliance to ANSI/NSPI-5 - Standard for residentialIn-Ground Swimming Pools.INTERNATIONAL SWIMMING POOL & SPA CODE -Electrical and bonding requirements shall comply withCURRENT NEC.ANSI/NSPI - Type O PoolBARRIER REQUIREMENTS PER STATE AND LOCAL CODE.NOTE:PROVIDE LAYOUT FORMS FOR POOLEQUIPMENT SLAB AND POUR SLAB WHENYOU GUNITE THE POOL1 ft. 6in.1 ft.10 ft.9 ft.14'x 26' Pool364 sq.ftDepth3' 8" to 7'Perimeter80 ft.AreaGallons16,000FEATURES; L.E.D. LIGHTINGSCALE 1/4 inch = 1 foot.18" x 24" PAPERA2 RECTANGLE 14' x 26'2 ft. 9 in.
LAYOUT SCALE 1/4 inch = 1 footPIPING PAGE5 Pipe Diam. StraightClear LengthFILTER DETAILFILTER3'' MAIN DRAIN SUCTIONWaste Line2'' CLEANER LINECONTROLSSWITCHESTIME CLOCK3 WAYVALVE3-wayvalve CHLORINATOR2'' SKIMMERHEATER5 Pipe Diam. StraightClear LengthHeater max. Temp.104deg. FProvide Cover onHeated pools18" Clear pipefor future Solar2-1/2'' RETURNLEGEND:R- RETURN LINE- ELEVATION- SKIMMER- VALVE ACTUATORNTS- BUTTERFLY VALVE- CHECK VALVE- 2-WAY VALVE- 3-WAY VALVE- NOT TO SCALEPOOL EQUIPMENT SLAB DETAILSFORM ALL 4 SIDES OF NEW EQUIPMENTSLAB W/ SEPARATION FROMRESIDENCE AND ANCHOR EQUIPMENTTO SLAB AS REQUIRED.POUR CONCRETE EQUIPMENT SLABSAME TIME AS POOL FORCONSTRUCTION EXPEDIENCY ANDECONOMY.MAINTAIN 3' CLEARANCE FROM HEATERTO WINDOWS AND AVOID INSTALLATIONOF HEATERS BELOW ROOF OVERHANG.POOL EQUIPMENT COMPONENTPLACEMENT ON SLAB CAN VARY.PROVIDE FLOW FROM POOL TO PUMPTO FILTER TO HEATER TO CHLORINEGENERATOR TO POOLONE DIMENSION IS CRITICAL ANDSHOULD NEVER VARY; PROVIDE 5TIMES PIPE DIAMETER CLEARSTRAIGHT LENGTH ON SUCTION SIDEOF PUMPS.ALL PIPING TO BE PVC SCHEDULE 40MINIMUM AND ALL PRESSURE PIPINGAND MAIN DRAIN PIPING MUST BEPRESSURE TESTED PRIOR TO GUNITE(CONCRETE)PIPING NOTESPROVIDE 5 PIPE DIAMETERS CLEARLENGTH BEFORE PUMPS ON SUCTIONSIDEWELL WATER: IF POOL IS TOBE FILLED WITH WELL WATERPROVIDE PREFILTER WHENFILLING POOLPIPING TO BE INSTALLED 18" MINBELOW GRADE AND TRENCHES TOBE BACKFILLED W/ CLEAN SANDLOCATE SKIMMER TO TAKEADVANTAGE OF PREVAILING WINDSIN YOUR AREA ALL POOL PIPING SHALL BEAR THE N.S.F.-PW SEALOF APPROVAL AND SHALL BE SCHEDULE 40 P.V.C.MIN. POOL PIPING.WATER SUPPLY AND DISPOSAL SHALL BE SOARRANGED THAT THERE IS NO CROSS CONNECTIONWITH A DOMESTIC WATER SUPPLY OR WATERDISPOSAL SYSTEM.DESCRIPTIONPAGE3 OF 4DATE04/12/2023SCALE 1/4 inch = 1 foot.18" x 24" PAPERNOTES :POOL PIPING PAGEHEATER MAX. TEMPERATURE LIMITED TO 104 F.0IF WATER SOURCE IS A PRIVATE WELL, PRE-FILTERWATER TO FILL POOL.STEEL OVERLAP @ 48 TIMES DIAMETER.LOCATE POOL RETURNS DOWN 18" MIN. BELOWWATERLINE.SWIMMING POOL FILL HOSE TO BE EQUIPPED WITH AVACUUM BREAKER.IF ENCLOSURE IS REQUIRED PROVIDE SCREEN ORFENCE AROUND POOL OR PROPERTY. FENCE GATES TOBE SELF CLOSING AND SELF LATCHING.PROVIDE DOOR AND WINDOW ALARMS AS REQUIRED.DECK SHALL HAVE A SLIP RESISTANT FINISH WITH NOSHARP EDGES AND BE POSITIVELY SLOPED FORDRAINAGE.PROVIDE WEEP HOLES IN SHELL AND DEWATERINGPUMPS AND ANY OTHER METHODS NECESSARY TOPREVENT THE POSSIBILITY OF THE POOL FLOATINGDUE TO HYDROSTATIC UPLIFT PRESSURE WHEN THEPOOL IS EMPTY.BACKFILLING OF THE POOL SHALL BE DONECAREFULLY TO ASSURE NO DAMAGE TO THE PIPINGOCCURS AND BACKFILL SHALL BE DONE WITH CLEANSOIL FREE FROM ORGANICS AND DEBRIS AND SHALLBE COMPACTED SO THAT NO VOIDS EXIST PROVIDINGA FIRM BEARING FOR THE DECK.ALL PIPING TO BE SCHEDULE 40 MINIMUM AND ALLPRESSURE PIPING AND MAIN DRAIN PIPING MUST BEPRESSURE TESTED PRIOR TO GUNITE (CONCRETE).ALL METALLIC ITEMS WITHIN 5'-0" OF WATER'S EDGE OFPOOL TO BE BONDED WITH #8 SOLID INSULATED WIRE(U.L. LISTED) TO POOL STEEL. ALL GROUND WIRESCONNECTED TO POOL STEEL WITH BRASS GROUNDLUGS..... G.F.I. OUTLET 10' MIN. AND 20' MAX. FROMPOOL.ESTABLISH THE LOCATION OF ALL UTILITIES ATSWIMMING POOL CONSTRUCTION SITE AND HOLDMINIMUM CLEARANCE DIMENSIONS ESTABLISHED BYTHE REGULATORY AGENCY. ALLOW 10' MIN.HORIZONTAL CLEARANCE FROM OVERHEAD ELECTRICWIRES TO POOL WATER.NOTES :PIPING PAGEPOOL EQUIPMENTPLUMBING ISSHOWN SPACEDFOR CLARITY2-1/2" RETURN LINE3" POOL MAIN DRAINSKIMMER2" VACUUM LINE2" SKIMMER LINEConduit for 12V light2"HEATER MAX. TEMPERATURE LIMITED TO 104 F.02.5 H.P. HAYWARD VS PUMPPROVIDE LANDSCAPEBARRIER AROUNDPOOL EQUIPMMENTHAYWARD W-400 1-1/2" VACUUMFITTING INSTALLED 6" to 12"BELOW WATERLINEVGB APPROVED AQUASTAR CHANNEL DRAIN12 VOLT LIGHTS(3) DIRECTIONALRETURN INLETSPROVIDE 2" DRAIN LINE TO POP UP FITTINGAS REQUIREDRRR7'DeepConduit for 12V lightConduit for 12V lightHEATER MAX.TEMPERATURELIMITED TO 104 F.014' x 26' Pool364 sq.ftDepth3' 8" to 7'Perimeter80 ft.AreaGallons16,000FEATURES; L.E.D. LIGHTINGSCALE 1/4 inch = 1 foot.18" x 24" PAPERA2 RECTANGLE 14' x 26'3'-8"Deep1 ft.1 ft. 6in.1 ft.2" SKIMMER LINEConduit for 12V light
PAVER DECK DETAIL26'POOL SECTION12"MAXIMUM FLOOR SLOPE 1 ft. IN 7 ftScale: 1/4" = 1'4' MIN.VGB APPROVED MAIN DRAIN GRATESECURED IN PLACE SO TOOLS ARE REQUIRED FOR REMOVALHYDROSTATIC VALVE WITH WELLPOINTGRAVEL SUMP"J" BOX 12" MIN. ABOVEWATERLINETRANSFORMER5' MIN.7 ft.4 ft.12"12"12"10"10"10"10"3'8" ft.VARIES7'1'LIGHT NICHE DETAIL#3 STEELDIAGONALLIGHT2 #3 STEELBOTH WAYSPROVIDE 3"MIN COVERHEATER MAX. TEMPERATURELIMITED TO 104 F.0IF GROUND WATER IS ENCOUNTERED DURING EXCAVATION, PROVIDE HYDROSTATIC PRESSURE RELIEF AND 4" CLEAN GRAVEL BASE UNDER THE POOL FLOOR WATERBOND DETAILUSE W/ PLASTIC NICHE &NICHELESS LIGHTSWATER BONDFITTING PB2008NOTE: WATERBOND FITTING TO BEBELOW WATERLINE AT ALL TIMESPOOL RETURN LINEPOOL PUMPBOND BEAMDETAILWATERLINE8" WALLS W/#4 STEEL @ 9''O/C BOTH WAYS12" x 24" MIN. BEAM W/4 #4 BARS CONTINUOUSAND BACK SLANTEDWALL12"24"COLD CLIMATESW/ FREEZINGTEMPERATURES4,000 PSI MIN.CONCRETEWATERLINE6" WALLS W/#3 STEEL @ 9''O/C BOTH WAYS10" x 10" BEAM W/#3 BARS CONTINUOUS10"10"STANDARD NORMALSOIL CONDITIONS W/NO ADDITIONALSTRUCTURAL LOADS3,000 PSI MIN.CONCRETEBOND BEAMDETAILNOTE:OBSERVE LOCAL SETBACK REQUIREMENTS TO POOL, DECK &EQUIPMENT SLABS (DISTANCES TO PROPERTY LINES),NO CONSTRUCTION SHALL PROTRUDE INTO EASEMENTS.POOL WATER MUST BE 10' MINIMUM HORIZONTAL DISTANCEFROM ANY OVERHEAD POWERLINES.SKIMMER PLAN VIEW18" MIN. LAPPOOL BEAMMIN. 3" CONCRETECOVER(2) #3 BARS6"TYP.3"3"3"6"30"SET SKIMMERPLUMB & LEVEL#3 BARS TYP.MIN. 3" CONCRETECOVER3"3"MIN. 3" CONCRETECOVERSKIMMER SECTIONCOPINGANTI-ENTRAPMENTMAIN DRAIN DETAILVGB COMPLIANTAQUASTAR MAIN DRAIN 32CDFL101 -316 GPM @ 3.9 FPSFLOOR INSTALLATIONMAIN DRAINPOOL/ SPA32" CHANNEL DRAINEQUIPOTENTIAL BONDING GRID#8 AWG BARE SOLID COPPER BONDING JUMPER SHALL BEINSTALLED IN AT LEAST FOUR (4) LOCATIONS AROUND PERIMETEROF THE POOL OR SPA AND CONNECT POOL STEEL TO DECK STEELOR BOND GRID WITH APPROVED LUGS.PER 2014 NEC (680.26C "EQUIPOTENTIAL BONDING GRID"): POOL(EXAMPLE)BOND GRIDEYEBALL INLET FITTING (NTS)EYEBALL INLETS ARE ADJUSTABLE AND DO NOTPROTRUDE INTO POOL12"POOL PLASTERROTATION BALLRETAINER RINGESCUTCHEON PLATE12" MIN. FROMWATERLINEWATERLINEEQUIPMENT ANCHORAGE DETAILFILTERPUMP4" THICK CONCRETE SLAB1/4" TAP CON BOLTS 3"LONG @ (4) LOCATIONS1/4" TAP CON BOLTS1/4" TAP CON BOLTSHEATERSWIMOUT / BENCH DETAIL18"18"TILE TRIM INCONTRASTINGCOLORFINISH GRADINGGRADE AROUND FINISHED POOL & DECK. SLOPE TO PROVIDE RAIN WATER RETENTION ON SUBJECT PROPERTY. PROVIDE BERMS & SWALES AS NECESSARY. DO NOT DRAIN TO NEIGHBOR'S PROPERTY OR TO LAKES, CANALS, STREETS OR OTHER UNLESS APPROVED TO DO SO. FINISHING NOTES1.2.3.4.5.6.FILL ALL VOIDS WITH HYDRAULICCEMENT OR POOL PATCH.PROVIDE CLEAN, SMOOTH SURFACE. WASH W/ MURIATIC ACID IF NECESSARY.APPLY BOND COAT AND INSTALL NEW DIAMOND BRITE FINISH, PEBBLE TEC OR OTHER AGREGATE FINISH, INSTALL EYEBALL FITTINGS, FEATURE FITTINGS, JET FITTINGS, ETC., AND VGB APPROVED MAIN DRAIN COVER.FILL POOL W/ POTABLE WATER (THROUGH A FILTER) IF NECESSARY. ADD CHEMICALS AS RECOMMENDED BY A PROFESSIONAL OR A POOL WATER TEST KIT.ALLOW 4 WEEKS AFTER POOL IS FILLED WITH WATER BEFORE ADDING SALT TO POOLS EQUIPPED W/ SALT CHLORINE GENERATOR.POOLS W/ ALL TILE FINISH SHOULD BE WATERPROOFED PRIOR TO INSTALLING TILE. PROVIDE DECK DRAINS & EXPANSIONJOINTS AS REQUIREDSLOPE DECKS 1/8" TO 1/4" PER FT.AWAY FROM POOL10"X 10" FOOTER W/2 #5 CONT.4" MIN.10/10 WIRECONCRETE DECK DETAILLIGHT NICHE DETAIL18"WATERLINE12V LIGHT W/ AWET NICHEPOOL STEELGROUND LUG18" MIN. FROMWATERLINECOAT BOND CONNECTIONWITH A POTTING COMPOUNDLOCATE SKIMMER TO TAKE ADVANTAGEOF PREVAILING WINDS IN YOUR AREALIGHT NICHE DETAILWATERLINE12VNICHELESSLIGHTPVCUSE WATERBONDSEE DETAILPool Steel overlap @ 48 times diameterGUNITE, SHOTCRETE, CONCRETE POOLSLOPE DECKS 1/8" TO 1/4"PER FT. AWAY FROM POOLPROVIDE 3" MIN COVER TO DIRTAND 2" MIN. COVER TO WATERALL METALLIC ITEMS WITHIN 5'-0" OF WATER'S EDGE OF POOL TO BE BONDED WITH #8 SOLIDINSULATED WIRE (UL listed) FROM POOL STEEL. ALL GROUND WIRES CONNECTED TO STEEL WITHBRASS GROUND LUGS......G.F.I. OUTLET 10' MIN. AND 20' MAX. FROM POOLDECK DETAILDIAMOND BRIGHTPLASTER FINISHLIGHT CORD(IN 1" CONDUIT)4' MIN.EXISTINGELECTRICPANELPOOLPANELG.F.I.(NOTE BELOW)"J" BOX220VPUMPMOTOR#8 AWG INSULATEDCOPPERWIRE EPOXYCOATEDALL ELECTRICAL PER 2014 N.E.C.ALL EQUIPMENT TO BE INSTALLED PERMANUFACTURER SPECIFICATIONS3 #12 IN 1/2"CONDUITPROVIDE 3" MIN COVER18" MIN.12V LEDLIGHTGFI PUMPBREAKERS#8 AWG BARE SOLIDCOPPER BONDINGJUMPERCOMPACTED FILL3 #12 IN 1/2"CONDUITHAYWARD2.5 H.P.VS16 A3- #3 REBAR CONT.IN 10" X 10" BEAM6" FLOOR W/#3 STEEL @ 9''O/C BOTH WAYS6" WALLS W/#3 STEEL @ 9''O/C BOTH WAYS10"LIGHT SWITCH15ACHLORINATOR COPINGPAVERDECK30A100W TRANSFORMER#3 REBAR =18" MIN. LAPSCOAT BOND CONNECTIONW/ APPROVED POTTINGCOMPOUND20A GFI#4 REBAR =24" MIN. LAPSHEATER15A15ACEMENTEDGE10"EXPANSIVE SOIL CONDITIONS, SLOPES,RETAINING WALLS, ADJACENTSTRUCTURES, LOCATION ANDFEATURES MAY REQUIRE ADDITIONALSTRUCTURAL REINFORCEMENT.STRUCTURAL NOTEEXPANSIVE SOIL CONDITIONS, SLOPES,RETAINING WALLS, ADJACENT STRUCTURES,LOCATION AND FEATURES MAY REQUIREADDITIONAL STRUCTURAL REINFORCEMENT.ALL CONCRETE SHALL CONFORM TO A.C.I318-11. CONCRETE SHALL HAVE A MINIMUMCOMPRESSIVE STRENGTH OF 3,000 PSI FORPNEUMATICALLY PLACED CONCRETE(GUNITE/SHOTCRETE)PIPING: ALL POOL PIPING SHALL BEAR THEN.S.F.-PW SEAL OF APPROVAL AND SHALLBE SCHEDULE 40 P.V.C. MIN. POOL PIPING.WATER SUPPLY AND DISPOSAL SHALL BESO ARANGED THAT THERE IS NO CROSSCONNECTION WITH A DOMESTIC WATERSUPPLY OR WATER DISPOSAL SYSTEM.EQUIPOTENTIAL BONDING GRID SHALL BEINSTALLED PER NEC SECTION 680.26(C)DESCRIPTIONPAGEDATE04/12/2023SCALE 1/4 inch = 1 foot.18" x 24" PAPERINSTALLATION IS TO BE DONE INACCORDANCE WITH ALL FEDERAL, STATEAND LOCAL BUILDING CODES INCLUDINGANSI/NSPI 3, ANSI/NSPI 5, ANSI/APSP 7,ANSI/APSP/ICC 15DESIGN BASED ON SITE WITHUNDISTURBED SAND & ROCK, WITH AMINIMUM BEARING VALUE OF 2000 PSF.GENERAL NOTES:DETAIL PAGEREINFORCING STEEL SHALL BE ASTMDESIGNATION A615 GRADE 60 WITH A MINIMUMYIELD STRESS OF 60 KSI. REINFORCING BARSSHALL BE NEW DEFORMED BARS OF BILLETSTEEL FREE FROM OIL, SCALE OR RUST. ALLSPLICES, LAPS AND PLACEMENT SHALLCONFORM TO ACI 318-89. ELECTRICAL DETAILSSTRUCTURAL DETAILSA2 RECTANGLE 14' x 26'364 sq.ftDepth3' 8" to 7'Perimeter80 ft.AreaGallons16,000