HomeMy WebLinkAboutEngineer PlanGENERAL NOTES 1. ELEVATION, PROPERTY LINE AND EXISTING CONDITIONS ON THIS PLAN ARE BASED ON A SURVEY CONDUCTED BY STRONG TREE ENGINEERING. 2. UNLESS OTHERWISE NOTED, ALL SYSTEM COMPONENTS AND CONSTRUCTION METHODS SHALL BE IN ACCORDANCE WITH THE STATE ENVIRONMENTAL CODE AND THE RULES AND REGULATIONS OF THE LOCAL BOARD OF HEALTH. 3. THIS PLAN IS INTENDED TO ADEQUATELY PROVIDE THE INFORMATION NECESSARY TO LAYOUT AND CONSTRUCT THE PROPOSED SEWAGE DISPOSAL SYSTEM REPRESENTED ON IT. ANY CHANGES TO THIS PLAN MUST BE APPROVED BY THE ENGINEER AND/OR THE LOCAL BOARD OF HEALTH (BOH) STAFF. THE CONTRACTOR SHALL REPORT ANY DISCREPANCIES FOUND IN SITE CONDITIONS FROM THOSE SHOWN ON THE PLAN TO THE DESIGN ENGINEER. 4. TRENCH SAFETY SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR INCLUDING ANY LOCAL AND/OR STATE PERMITS REQUIRED FOR THE TRENCH WORK. 5. CONTRACTOR TO PUMP SEPTIC TANK/STRUCTURES. FAILING TO PROPERLY INSPECT OR PUMP THE SEPTIC TANKS AND TREATMENT SYSTEM OR CHANGES TO EFFLUENT FLOW, GRADING, OR LANDSCAPING, EITHER ON -SITE OR ADJACENT TO THE SITE, MAY RESULT IN IMPROPER FUNCTIONING OF THE SEPTIC AND LEACHING SYSTEM(S). 6. CALL "DIGSAFE" AT LEAST 72 HOURS PRIOR TO COMMENCING CONSTRUCTION AT 1-888-DIG-SAFE AND ANY OTHER APPLICABLE AGENCIES TO FIELD VERIFY LOCATIONS OF EXISTING UTILITIES. 7. THE OWNER SHALL INSPECT AND PUMP THE SEPTIC TANK ONCE EVERY 2 YEARS. PERPETUAL MAINTENANCE IS REQUIRED. 8. THIS ON -SITE WASTEWATER TREATMENT SYSTEM IS NOT DESIGNED FOR USE WITH A GARBAGE GRINDER. 9. PROVIDE WATERTIGHT SEALS BY USE OF NON -SHRINK GROUT AT ALL POINTS WHERE PIPES ENTER OR LEAVE ANY CONCRETE STRUCTURES. 10. USE SCHEDULE 40 PVC PIPING WITH WATERTIGHT JOINTS UNLESS OTHERWISE NOTED ON PLAN. ALL PIPE SHALL BE PLACED ON A COMPACTED FIRM BASE. 11. THE CONTRACTOR SHALL RESTORE ALL SURFACES EQUAL TO THEIR ORIGINAL CONDITION AFTER CONSTRUCTION IS COMPLETE. AREAS NOT DISTURBED BY CONSTRUCTION SHALL BE LEFT NATURAL. THE CONTRACTOR SHALL TAKE CARE TO PREVENT DAMAGE TO SHRUBS, TREES, OTHER LANDSCAPING AND/OR NATURAL FEATURES. WHEREAS THE PLANS DO NOT SHOW ALL LANDSCAPE FEATURES, EXISTING CONDITIONS MUST BE VERIFIED BY THE CONTRACTOR IN ADVANCE OF THE WORK. 12. EXISTING SEPTIC SYSTEM TO BE REMOVED OR BACKFILLED AND ABANDONED PER TITLE 5 REQUIREMENTS.TITLE 5,310 CMR 15.354(3). 13. AREAS UNDER THE LEACHING FIELD FOUND TO HAVE UNSUITABLE SOIL MUST BE REPLACED WITH TITLE 5 SAND AS SPECIFIED IN 310 CMR 15.255(3). ANY AREAS THAT ARE FOUND TO HAVE UNSUITABLE MATERIAL SHALL BE REPORTED TO THE ENGINEER. 14. PRIOR TO CONSTRUCTION THE CONTRACTOR SHALL COORDINATE WITH THE HOMEOWNER AND ENGINEER ON THE CONSTRUCTION SITE ACCESS AND MATERIAL STOCK PILE AREAS. 15. INSTALL METALLIC DECTABLE WARNING TAPE 6-9-INCHES ABOVE THE SEWER PIPE AND SEPTIC STRUCTURES. 16. 36 INCH MAX COVER OVER H-10 STRUCTURES. INSTALL TEES PER DETAILS NOTES: PIPE PENETRATIONS: ALL CONNECTIONS TO HAVE NON PAVEMENT: SET WATER TIGHT HYDRAULIC CEMENT SEAL COVER 6"± BELOW GRADE Liquid Depth in Depth of Outlet Tee PAVEMENT: MANHOLE TO Septic Tank below Flow Line SURFACE GRADE 4 feet 14 inches 5 feet 19 inches FINISH GRADE OVER TANK EL.= SEE SITE PLAN SURFACE TREATMENT: SEE SITE P`LAND,\/\\j\\j\\j\\j\\j\\j\\j\\j\\j\\j\\j\\j\\j\\j INVERT BUILDING EL. POLYLOK PL-68 OR ZABEL (SEE SCHEDULE) EFFLUENT FILTER 4" SCH. 40 PVC 3" TYP. INVERT IN--------- - TANK EL. INVERT OUT 10' MIN. e TANK EL. INLET TEE 10" MIN. BELOW FLOWLINE SEE TABLE 6" 3/4" COMPACTED CRUS' r1tU a I UIVC WAOrz __\Z__ EST. SEASONAL HIGH WATER EL.: SEE SCHEDU 1,500 GALLON SEPTIC TANK PROFILE H-10 LOADING NOT TO SCALE NOTES: 1. DISTRIBUTION BOX TO BE INSTALLED ON LEVEL STABLE BASE. 2. INSTALL FIRST 2 FEET OF OUTLET PIPES LEVEL (NO SLOPE). ONE OUTLET FOR EACH DISTRIBUTION LINE. OUTLETS NOT USED SHALL BE CAPPED PIPE PENETRATIONS: WATER TIGHT COVER: SET ALL CONNECTIONS TO HAVE WATER CONCRETE ACCESS HATCH OR TIGHT HYDRAULIC CEMENT SEAL MANHOLE COVER 6" BELOW GRADE \ i -\I/ \ r -\I/ \ r -\L \ / \Ir I -\I/ EL.: SEE PLAN\I/ LOAM & SEED FLOW 4" SCH 40 PVC FROM f SEPTIC TANK I NATIVE MATERIAL OR GRANULAR FILL TOP OF D-BOX >�//\ 21. \ \ FLOW .. 10 4" SCH 40 PVC TO SEPTIC FIELD 6" MIN. SUMP 6 OF 3/4 COMPACTED CRUSHED STONE BASE PROPOSED DISTRIBUTION BOX DETAIL H-10 LOADING NOT TO SCALE LE SEPTIC SYSTEM TITLE 5 DESIGN USE - SINGLE FAMILY DWELLING NUMBER OF BEDROOMS EXISTING 2 FUTURE ADU NUMBER OF BEDROOMS 1 PROPOSED DESIGN FLOW BEDROOMS 3 TITLE 5 FLOW PER BEDROOM 110 GPD TOTAL DAILY FLOW 330 GPD SEPTIC TANK 2XTHE DAILY FLOW PER TITLE 51 660 PROPOSED 1,506 GALLON TANK SOIL ABSORPTION SYSTEM LEACHING SYSTEM USED GALLERY TRENCH SOIL CLASS I SAND FIELD PERCOLATION RATE 2 MINAN- LONG TERM ACCEPTANCE RATE (LTAR) 0-74 GPD/S.F. TOTAL AREA REQUIRED - TITLE 5 446 S.F. PROPOSED OVERALL LENGTH 30.5 FT PROPOSED OVERALL WIDTH 9.83 FT BOTTOM CAPACITY (LENGTH x WIDTH) 299 S.F. SIDEWALL LENGTH: (LENGTH + WIDTH x2) 81 FT SIDEWALL DEPTH 2 FT SIDEWALL AREA: (TOTAL LENGTH) x (DEPTH) 161 S.F. NUMBER OF TRENCHES 1 SIDEWALL CAPACITY: AREA x TRENCHES 161 S.F. TOTAL CAPACITY 460 S.F. TOTAL ALLOWABLE FLOW 340 I GPD USE 3-500 GALLON LEACHING CHAMBERS W/ 2.5' STONE SCHEDULE OF ELEVATIONS EL• (FT} RUN SLOPE ESTIMATED EXISTING HOUSE - OUTLET 17.20 11-00 1.00% SEPTIC TANK - INLET 17.09 SEPTIC TANK - OUTLET 16.84 22.00 1-00% "D" BOX - INLET 16.62 "D" BOX - OUTLET 16.45 2.00 0.00% 11.00 1.00% GALLERY INLET 16.34 GALLERY BOTTOM TO INVERT 2.00 GALLERY - BOTTOM EL. 14.34 TOP OF SAS / BREAKOUT 17.18 LOWEST FINISH GRADE 19.00 MINIMUM COVER 1.82 HIGHEST FINISH GRADE 19.50 MAXIMUM COVER 2.32 EST. ELEV. TO SUITABLE MATERIAL 7.2 TEST PIT BOTTOM 7.90 ESTIMATED HIGH G.W. 9.20 CONFIRMED SEPARATION TO G.W. 5.1 4-INCH PVC THREADED CAP 6 INCH DI H-20 CURB BOX W/ COVER SET IN 6 INCH BED OF CONCRETE WHERE IN PAVEMENT 3-4" BELOW SURFACE NI/ \�/\\/\\/\\/ \/\\/\\/\\/ .\ LEAN BACKFILL / FREE OF STONES GREATER PROVIDE ADAPTER TO ,l _ \ _ \,,\\�j�i//\�/i�\/ THAN 2 INCHES IN DIAMETER JOIN SEWER OR LATERAL \ TO 4-INCH ELBOW 45 DEGREE PVC BEND AT THE END y` OF LINE OR WYE CONNECTION -- FLOW FOR IN LINE �, NX TYPICAL CLEANOUT DETAIL NOT TO SCALE FINISH GRADE OVER CHAMBERS 3/4" TO 1-1/2" DOUBLE WASHED STONE TO CROWN OF PIPE 4 SCHEDULE 40 PVC SLOPE @ 2% MIN. OVER SYSTEM 2" OF 1/8" TO 1/2" DOUBLE WASHED MIN SLOPE 1% STONE OR NON -WOVEN FILTER FABRIC SEE SITE PLAN FOR PLACE RISERS ON ALL CHAMBERS WITH PIPED INLETS SURFACE TREATMENT (FIRST ROW) TO WITHIN 6" OF FINISHED GRADE TOP OF SAS OVERDIG AND BACKFILL 9" MIN. TITLE 5 SAND IF NECESSARY INLET 36" MAX. BREAKOUT EL = SEE SCHEDULE (SEE TEST PIT LOGS) 34"± /\ 5' MIN. / \ o 2.0' \ i " SIDEWALL X, 0 0 0 0 0 0 0 0 0 BELOW INVERT \ r /\ • \�\\ �\ �\\\��\\�� \ r/\\ 5' MIN. / 2.5' 8.5' (TYP) 2.5' 2.5' SEE SITE PLAN FOR TOTAL LENGTH (100' MAX) BOTTOM OF SYSTEM GROUND WATER = SEE SCHEDULE " EXISTING CLEAN BACKFILL OR NATIVE CHAMBER PROFILE VIEW 5' MIN. MATERIAL OUTSIDE SYSTEM 500 GALLON PRECAST LEACHING CHAMBER/GALLEY DETAIL H-10 LOADING NOT TO SCALE 2.5' 4.83' (58") (TYP.) SEE PLAN FOR TOTAL FIELD WIDTH CHAMBER END VIEW * GROUNDWATER ELEVATION ESTIMATED FROM TEST PITS ONSITE AND AVAILABLE GROUNDWATER MAPS FOR THE TOWN SOIL TEST PIT DATA PERFORMED BY: JUSTIN LAMOUREUX, P.E., SOIL EVALUATOR WITNESSED BY: BREWSTER HEALTH DEPARTMENT - BARRY LEWIS DATE: AUGUST 14, 2024 "I certify that I have passed the examination approved by the Department of Environmental Protection and that the above analysis has been performed by me consistent with the required training, expertise, and experience described in 310 CMR 15.018(2). " SURFACE TP-1 ELEV. SURFACE TP-2 ELEV. INCHES FEET INCHES FEET 0.0 " 17.2 0.00. 17.9 F" A SANDYLOAM co A SANDY LOAM 10YR 5/1 10 10YR 5/1 0 2.0 " 17.0W 2.0 " 17.7 fW 'a E LOAMY SAND LOAMY SANDa 7.5YR 5.1 E 7.5YR 5.1 ix 3-0 " 17.0; 3.0 " 17.7 06 10 O B LOAMY SAND 1 W B LOAMY SAND ,W 10YR 5/8� 10YR 5/8 40.0 " 13-9 44-0 " 14.2 C MEDIUM SAND C MEDIUM SAND 10YR 6/8 10YR 6/8 120.0 " 1 17.2 120.0. 7.9 MOTTLING 96 INCHES MOTTLING 105 INCHES G.W. 106 INCHES G.W- 115 INCHES PERC RATE: 2 MIN/INCH I PERC RATE: 2 MIN/INCH / N \ OyW f �� \� O �k w PARCEL .2 LOCUS PLAN 1 INCH = 200 FEET SCALE BAR 20 0 10 20 40 (in feet) 1 INCH = 20 FEET STRONG TREE ENGINEERING P.O. Box 977 East Sandwich, MA 02537 Ph: (774) 559-3942 www.strongtree.engineering Revisions REV. DATE BY CHECK DESCRIPTION 0 ZA # # I # # A # # # # ® # # # # PROJECT: RESIDENTIAL SEPTIC UPGRADE 6 DAUPHINE DRIVE YARMOUTH, MA 02675 SHEET TITLE: SEPTIC SYSTEM UPGRADE PREPARED FOR: TIFFANY & NICHOLAS CALLAHAN 6 DAUPHINE DRIVE YARMOUTH, MA 02675 Registration: Project Number: Sheet: ,�� OF Mqs �� 24094 1 of 1 tJ J. G O Jul 0 IJ�M ,L N Sh t Number: u 7371 C-1 Date: r 44 08-27-2024 r- O O 0 "VVELLING �' PROPERTY INFORMATION O Fug #6 RECORD OWNER: TIFFANY AND NICHOLAS CALLAHAN UT POLE GROUND / ADDRESS: 6 DAUPHINE DRIVE, YARMOUTH PORT, MA 02675 59'*LEVEL MAILING: 6 DAUPHINE DRIVE, YARMOUTH PORT, MA 02675 > 's 17 ' PARCEL ID: 133/33.1 O ENV 44 SF± DECIQ ASSESSORS ASSESSORS lz� LOT SIZE: 30,667 S.F t (0.70 AC.), TOTAL BOTH LOTS: 1.03 ACRES OUT FF ELEV PARCEL O ZONING: R-40 17.2'* ZO 7 , PARCEL 18.0' �G O 2 BEDROO ^00 133-33.1 133-33.1 �O USE: SINGLE FAMILY RESIDENTIAL F M AREA 30,667 AREA 0.31 AC z \' O SF± SINK GARBAGE DISPOSAL: NOT ALLOWED G) SEPTIC I OS (0.70 AC) Lu THE PROPOSED SEPTIC IS NOT LOCATED IN A FLOOD ZONE =Q \ 3 :5' ;' O � APPROX AC iRR //�� M SITE IS NOT LOCATED WITHIN A NITROGEN SENSITIVE AREA LOCATE/CON CT TO EX. 4" PIPE 1on � SITE IS NOT LOCATED WITHIN A WELLHEAD PROTECTION ZONE IL O I / o REMOVE/ ABA ON EX. : , 4,� SCH. 40 PVC / Z ^ O SITE IS NOT LOCATED WITHIN THE TITLE 5 SETBACK AREA SEPTIC PER TLE 5 & (ALL PIPE) p LOCAL REG TIONS O 9:$': :., i OSOIL SURVEY DESIGNATION: CARVER LOAMY COARSE SAND (259B) _ T OP ��S - O� �� THERE ARE NO KNOWN PRIVATE WATER SUPPLY WELLS WITHIN 100 PROPOSEDSi ITARY I 18.0 / / / G\�l PLAN FROM THE PROPOSED SEPTIC SYSTEM AS SHOWN IN THE SITE ABSORPTION 'STEM I / TP 1 / Pg5 / /FF5 2 `tS THERE ARE KNOWN WETLAND RESOURCES WITHIN 100 FEET OF THE / Q5 PARCEL. THE SEPTIC SYSTEM/LIMIT OF WORK AS SHOWN IN THE SITE PLAN HAS BEEN DESIGNED TO NOT IMPACT THE BUFFER ZONE. INSTALLATION INSPECTION NOTES N88' 29' 19"E '� 1. THE CONTRACTOR SHALL PROVIDE A MINIMUM OF 24 HOURS 115.00' ADVANCE NOTICE TO THE ENGINEER AND LOCAL BOARD OF r- HEALTH FOR ANY INSPECTION. \ O 2. ALL WASTEWATER SYSTEMS SHALL BE INSPECTED BY THE o O ENGINEER OR THE LOCAL BOH REPRESENTATIVE PRIOR TO N BACKFILLING. AT A MINIMUM THE FOLLOWING ITEMS SHALL BE m INSPECTED: 2.1. ALL SYSTEM COMPONENTS BASE AND INSTALLATION PRIOR TO BACKFILL 2.2. ABANDON EXISTING SYSTEM 2.3. FINAL INSPECTION OF BACKFILLED SYSTEM 3. THE CONTRACTOR SHALL BE RESPONSIBLE TO MAINTAIN UP-TO-DATE AS -BUILT DRAWINGS AND NOTES INDICATING THE HORIZONTAL AND VERTICAL LOCATION WITH TWO TIES OF ALL SYSTEM COMPONENTS INSTALLED FOR SUBMISSION TO THE MUNICIPALITY.