Loading...
HomeMy WebLinkAboutEngineer PlanPROV'D H.D.P.E. RISER w/ i.: -12.1 t � � , , PROP. VENT WITH CHARCOAL FILTER TO ABOVE GRADEPROVIDE H.D.P.E, REMOVABLE, SECURED, FINISH GRADE OVER D-BOX = 13,Q FINISH GRADE OVER CHAMBERS = 13,Q - 13.2 „ F.G. OVER ° 3/4 TO 1-1/2 DOUBLE WASHED FINISHED GRADE RISER w/ COVER TO WATER -TIGHT COVER TO SLOPE @ 2 to MIN. OVER SYSTEM 1. UNLESS OTHERWISE NOTED, ALL SYSTEM COMPONENTS AND CONSTRUCTION @ FOUNDATION = 12.0'± WITHIN 6" OF F.G. TANK EL.= 12.1 12.4 F.G. (TYP OF 2) REMOVABLE WATER -TIGHT COVER OVER STONE TO CROWN OF PIPE METHODS SHALL BE IN ACCORDANCE WITH TITLE 5 OF THE STATE ENVIRONMENTAL RISER TO WITHIN 6" OF FINISHED GRADE 4" SCHEDULE 40 PVC i 2" OF 1/8" TO 1/2" DOUBLE WASHED CODE AND ANY APPLICABLE LOCAL RULES. f 30" MIN. 12 MAX' 5" DIA. OUTLET(S) MIN SLOPE 1% STONE OR GEOTEXTILE FILTER FABRIC 2. ANY CHANGES TO THIS PLAN MUST BE APPROVED BY THE BOARD OF HEALTH AND THE ' DISCONNECT 3,73 PROP. VALVE DESIGN ENGINEER. SEE NOTE 22 _ . 2a" MIN. ACCESS 11 TOP OF SAS = 1 Z.O3' PLACE RISER ON ALL 3. 4" SCHEDULE 40 PVC PIPE WITH WATER TIGHT JOINTS SHALL BE USED IN DISPOSAL EL 8 6T S 11.00 2 SCH. 40 9 MIN• 9" MIN CHAMBERS w/ PIPED SYSTEM UNLESS OTHERWISE NOTED. PROP. 4" COVER (TYP. OF 2) TO D-BOX 2" INLET TEE 36"MAX. 11.20' 36" MAX. INLETS TO WITHIN 6" H. 40 PVC i BREAKOUT EL = 1 1 .7O I OF FINISHED GRADE 4. TO PREVENT BREAKOUT, THE PROPOSED FINISHED GRADE SHALL NOT BE LESS THAN 19't �L ELEVATION = 11,70' FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE SAS. UNLESS A ' 2 DROP MIN. L = 52' ERTIGHT 40 MIL GEOMEMBRANE LINER IS PLACE AT LEAST FIVE FEET FROM SAS AND THE TOP OF MIN. SLOPE (c� 1% 6" 3" 3" DROP MAX. 3" 9" o, 14" ESHGW 9 EL_.6.2'± DIMENSION AS PER - _ ACME-SHOREY 7.25' TANK TO BE WATER -PROOF 48 LIQUID DEPTH AND WATER -TIGHT WITH POLYOLEFIN BACKED EXTERIOR JOINT WRAP 1500 GALS. 500 GALS. 6 CRUSHED STONE 10J' OFFSET OVER MECHANICALLY TO FND COMPACTED BASE EL .= 2.50- 22" ZABEL FILTER MODEL # Al801-4x22 (GAS BAFFLE ON BOTTOM) PROPOSED 1500/1500 GAL. T'/l0-CO%4PART. H-20 SFPTICTAKK & PUMP CHAMBER (LP) LENGTH 13'-011 WIDTH 7'-011 DEPTH 61-2' ALL TEES TO BE LINEDU DIRECTLY UNDER CENTER NOT TO SCALE OF RISER OPENINGS INSTALL 1-1/4 PVC TO HOUSE. JOINTS _..._ _. . ' NTS TO BE NOTE: PUMP MUST BE EQUIPPED MADE WATERTIGHT. WIRE PUMP AND - WITH A HIGH LEVEL ALARM LOCATED FLOATS TO SIMPLEX CONTROL PANEL No. `=--== IN THE BUILDING SERVED WHICH IS 1-CC2 NEMA-1 MFG. HOOVER INSTRUMENTS-12"MAx�POWERED BY A CIRCUIT SEPARATE +L FROM THE CIRCUIT TO THE PUMP, NEMA 4 JUNCTION BOX CORROSION RESISTANT r. & LIQUID -TIGHT CABLE CONNECTORS ` r � 2" SCH. 40 TO D-BOX SUPPORTED CONNECTORS SUPPORTED BY 1-1/4" 1 PVC CONDUIT, JOINTS TO BE MADE WATERTIGHT 2" BALL VALVE w/ UNIONS SCH, 80 PVC GEORGE FISHER CO. MODEL NO. 560 `!' I 2" SCH 40 TEE w/ CLEAN -OUT CAP /PROVIDE WAT JOINTS (TYP.) 2 SCH, 40 IN FROM�W] �`b� � � � O � � � � vff� �`b� � � THE LINER IS NOT LESS THAN THE BREAKOUT ELEVATION. PUMP CHAMBER 4" PVC OUT TO5, SLOPE ALL SOLID PIPE AT 1.0% MINIMUM. LEACHING FACILITY o �' ooa 6. THIS SYSTEM IS NOT DESIGNED FOR A GARBAGE DISPOSAL. 11.57`M N. 1211 6 '�1,40' 1' o o� 7. LOCAL BOARD OF HEALTH AND DESIGN ENGINEER TO BE NOTIFIED PRIOR TO BACK o FILLING WHEN SYSTEM IS NEARLY COMPLETE AND READY FOR INSPECTION. SYSTEM IS 6" CRUSHED STONE o o oQ NOT TO BE BACK FILLED WITHOUT FIRST OBTAINING APPROVAL FROM BOARD OF HEALTH OVER MECHANICALLY o AND DESIGN ENGINEER. r COMPACTED BASE 2 p, 6.0 ( (TYP) 4.0 (- 8. ELEVATIONS BASED ON NORTH AMERICAN VERTICAL DATUM OF 1988 (NAND 88). SEE ------ 4.0 5 OUTLET DISTRIBUTION BOX (TYP.) BASE. ) BENCHMARK LOCATION AND ELEVATION AS SHOWN ON PLAN. TO BE INSTALLED ON A LEVEL STABLE 34.0' BASE. FIRST TWO FEET OF OUTLET GROUND WATER ELEV.= 6.20' mott(in 9• CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS PRIOR TO CONSTRUCTION PIPES TO BE LAID LEVEL. 1 O.ZO 11.00, THROUGH DIG -SAFE AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE AT LC-5 Ci�iA'BERS 5.0' MIN. REQ'D CI`a,°�B�Rh;I]Q��/ 1-888-DIG-SAFE AND ANY OTHER APPLICABLE AGENCIES. REPORT ANY DISCREPANCIES ' 4.0 PROP. (See Gen. Note #22) TO THE DESIGN ENGINEER. CROSS SECTION VIEW TYPICAL CHANgER PROFILE w - - 10, ALL JOINTS WHERE PIPE ENTERS AND EXITS CONC. STRUCTURES SHALL BE MADE WATERTIGHT. i .; : u,-: :� v 4 i, .r 3 ` M.n e .,.. a ... •-. ?i . '• , 1•,' � :.. __ P-,# ^ _._ _ NOT TO SCALE NOT TO SCALE 11. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING REGULATOWNER/APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM SWING -TIES APPROPRIOTE. THAUTHORITY. DESCRIPTION HC-1 HC-2 TANK COVER IN (1) 41.2' 14.4' TANK COVER OUT (2) 49.9' 16. V CORNER OF STONE (3) 282 33.3' CORNER OF STONE (4) 29.9' 62.8' CORNER OF STONE (5) 22.4' 59.8' CORNER OF STONE (6) 19.9' 27.2' 10.70 LAS VEGAS, NV 89108 FEMA FLOOD ZONE X (<500) 8.70' COMMUNITY PANEL # 25001CO588J 17, DEED REFERENCE: BOOK 35392, PAGE 281 18. PLAN REFERENCE: P.B. 400, PG. 80 7.20' 6.2019. ALL DISTURBED AREAS SHALL BE RESTORED TO ORIGINAL CONDITION. 5.70' 20. PROPERTY LINE INFORMATION IS ONLY APPROXIMATE. THIS PLAN IS TO BE USED ONLY FOR SEPTIC SYSTEM UPGRADE. JC ENGINEERING WILL NOT ASSUME ANY LIABILITY FOR USES OF THIS PLAN OTHER THAN ITS INTENDED PURPOSE. 4.201 21. OWNER / APPLICANT / CONTRACTOR SHALL BE RESPONSIBLE TO OBTAIN ANY AND ALL REQUIRED PERMITS AND APPROVALS FOR THIS PROJECT. 22. IN ACCORDANCE WITH 310 CMR 15.401-15.405, THE FOLLOWING LOCAL UPGRADE APPROVALS ARE REQUESTED FROM 310 CMR 15.221(7) & 15.212(1): 1,) A 0.73' WAIVER (3.00' - 3.73') FOR THE MAXIMUM COVER OVER THE 1500/500 H-20 TWO -COMPARTMENT SEPTIC TANK / PUMP CHAMBER. 2.) A 1.0' WAIVER (5.0' - 4.0') FOR THE SEPARATION BETWEEN THE SAS AND ESHGW. 0.70' 7 f 0 GARAGE GE - - - - i 925> NUMBER OF BEDROOMS (EXISTING) 3 ! EXISTING (SLAP,) z_ - - r - - -- x;:0.0' EXISTING SPOT GRADE - - -- - -- • r NUMBER OF BEDROOMS (DESIGN) 3 , 3 E3EIRtaO%1 p EXISTING CONTOUR r I�V4'ELLlNt� ! DESIGN FLOW 110 GAUDAY/BEDROOM -- Yarm Y e "r Department (SLAB FND) ` t 0 r- 0 PROPOSED CONTOUR TOTAL DESIGN FLOW 330 GAUDAY �+ 1 - 1 Benchmark 1 DESIGN FLOW x 200% 660 GAUDAY 50 PROPOSED SPOT GRADE Corner of Stoop4 Name Date MAP 31 , _- ,- ' .w ' USE PROPOSED 1500/500 GALLON SEPTIC TANK /PUMP CHAMBER GAS EXISTING GAS LINE 1 Elev. = 12.57 _ __-------- 0 LOT 87 \ o EXISTING OVER HEAD WIRES } N.A. V. D. 88 ( it a. CHLM. _----' y 1 EXISTING WATER LINE a��. _ f HC-2 1 ° A HIN S W/ STONE X .. - INSTALL 5 LC-6 LE C G CHAMBER v ! i m J>� • ,� o , o ,- , A ( EXISTING LANDSCAPED AREA OCT 2 $ 2OZ4 , ti� ___ 00 SIDEWALL CAPACITY r a HC-1 - . N c� �. TEST PIT LOCATION ; HEALTH DEFT. :!11.1 (6 o PROPOSED -' ; (LENGTH + WIDTH) (2 SIDES) (1' HIGH) (0.74 GPD/S.F.) = GAUDAY 500/500 GALLON 2-COMPARTMENT i CLEAN -OUT ' (34.0 + 11.0) (2) (1) (0.74 GPD/ S.F.) 66.6 GAUDAY PROPOSED 1, 1 2) --PROP. 5 0/500-GAL rn �Q Ck- 1, 0 H-20 SEPTIC TANK /PUMP CHAMBER M- ,` ! "1 2-COMPART"SENT H-20 SEPTIC BOTTOM CAPACITY „ PROP. 410 fi'.'aiL. In,'�;�wii�li+"zl-i:=, `..? .C PIPE rI �s-r1 (5 am,., ,-,- -- !1' .- - • �; r �enrn GE0",'.�! BR, t ., E LI, x12 3 TANK I PUMP CI IAtti1F,L1. 9 G = PROPOSED 4 SOLID SCHEDULE 40 PV - � (LENGTH x WIDTH) (0.74 GPD/S.F,) GAUDAY TOP I--L.=11 70'; E-30T. EL,=33 10' `- AIN 1 3 / 40'x110') (0 � • TP 1 (3 .74 GPD/S.F.) = 276.8 GAUDAY Fg„� ._._ F��1 PROPOSED 2" SOLID SCHEDULE 40 PVC PIPE FORCEM # % (1 FROPOSED 4" SCH. 40 PVC VENT; (J -,, EXISTING LEACHING PROPOSED DISTRIBUTION BOX EXACT LOCATION PER OWNER -� 10k7' Q A CATCH -BASIN (TYP OF 2) , TOTALS: ^' = O ) ' r %� ' TOTAL NUMBER OF CHAMBERS 5 PROPOSED C LEACHING CHAMBER '' f �3 TOTAL LEACHING AREA 464.1 SQ.FT. REMOVE ALL UNSUITABLE o ` -� :� - -'' TOTAL LEACHING CAPACITY 343.4 GAL./DAY MATERIAL DOWN TO "C" SOIL - 34.0' , ' & REPLACE w/ CLEAN COARSE ' P411 -- -(� 35, t 3 REV. DATE BY APP'D. DESCRIPTION SAND PER 310 CMR 255(5) 10A a1 '' .W ; 5. PROPOSED SEPTIC SYSTEM UPGRADE' ' 12 -. j-� DOSING & STORAGE REQUIREMENTS �k�� ' (4 0 , : 12.0 - <, PREPARED FOR i DESIGN FLOW: 330 GPD' >:* ' ` J Jc"N ROBERT B. OUR CO., INC. PROPOSED FIVE (5) LC-6 I� L PRCFOSED DOSING REQUIRED: 6 CYCLES / DAY cl�l�ftc�+iLL sR. LEACHING CHAMBERS w/ STONE -� D#STRIBUTION _ - 7', 330 GPD / 6 = 55 GALS/CYCLE cl dil BOX y `; a. - cc re `_ NOTES: 1._ _ ' x t 1 0 DISTANCE REQUIRED BETWEEN PUMP LOCATED AT 25 WEST YARMOUTH ROAD ;� ,.> ON AND PUMP OFF FLOATS: i 1. MAGNETIC MARKING TAPE SHALL BE PLACED ALONG THE TOP EDGE OF EACH J _ WEST YARMOUTH MA SEPTIC SYSTEM COMPONENT. 5 MAP 31 ��� �,� 55 GALS/CYCLE -- 125 GAUFT = 0.44 FT/CYCLE ' - _ 1 `"j SE 0.50 TO PROVIDE FOR BACKFLO - _ -: LOT 89 i (U i SCALE: 1 INCH - 10 FT. DATE: OCTOBER 10, 2024 2. CONTRACTOR SHALL VERIFY SOIL CONDITIONS IN THE LOCATION OF THE ; ' _ - 1 PROPOSED LEACHING FACILITY TO ENSURE CONSISTENCY WITH TEST PIT - �w' - _._ -- - - i 1 STORAGE REQUIRED ABOVE WORKING LEVEL: 330 GAL." - 0 5 10 20 40 FEET DATA SHOWN ON THIS PLAN. REPORT TO ENGINEER AND LOCAL BOARD OF STORAGE PROVIDED ABOVE WORKING LEVEL: 337 GAL. HEALTH IF SOILS ARE NOT CONSISTENT WITH TEST PIT DATA. _ _ ___._..... _..__..__ __._.._ _..__._. _._.. _.. __ ry CHN y� I _ r �+ `. PREPARED BY ! _ I RESERVED FOR BOARD OF HEALTH USE �F'�pc`'I` �' '� JC ENGINEERING, INC. 3. ENTIRE PROPERTY IS NOT LOCATED WITHIN A MASS DEP ZONE It. _ J _ -.-- - - �� PAV1 '��1ENT -, ` ' U ���'''� NO. ' , 1 � I ` � / 2854 CRANBERRY HIGHWAY 4. SWING TIES SHOWN ON THIS PLAN ARE PROVIDED ONLY AS A COURTESY FOR THE INSTALLER. INSTALLER SHALL VERIFY SWING TIE MEASUREMENTS IN THE f r EAST WAREHAM, MA 02538 SITE PLAN 5O$.273.0377 I FIELD PRIOR TO INSTALLING THE SYSTEM. CONTRACTOR SHALL NOTIFY { � , , ,` ENGINEER IF MEASUREMENTS APPEAR TO BE INCORRECT IN THE FIELD. SCALE: 1" = 10' Drawn By: JTC Designed By: MCP Checked By: JLC JOB No. 8016 PROPOSED 1,5001500•*�'+ • ) `4 .,deg. 'i t' y r�Lewts (BOH) 12. ALL SEPTIC SYSTEM COMPONENTS SHALL WITHSTAND H-10 LOADING UNLESS LOCATED INSPECTOR: Bar GAL. 2-COMPARTMENT H-20 SEPTIC TANK (LP) '+ " •`�' - !'/ Y - �'� 1; i,` EVALUATOR: Michael Pimente! EIT CS UNDER MORE THAN 3 FEET OF COVER OR LOCATED UNDER PAVEMENT, DRIVES, OR HIGH GROUNDWATER EL.= 6.2 _ .';,'' "' ' F TRAVELED WAYS IN WHICH CASE THEY SHALL WITHSTAND H-20 LOADING. TOP OF SEPTIC TANK EL. = 8.67 . f x. Oct. 27 1999 6", 3 �? ' "..` /._ C.S.E. APPROVAL DATE: E FREE O ALL DIRT DUST AND FINES. BOTTOM OF SEPTIC TANK EL. = 2.50' ''-':! ' Y �- `( `A - ` �; ' .j � •;-- ,ri �-`�� �' � ._..- -�� ,_ � � 13. DOUBLE WASHED CRUSHED STONE SHALL B EE F , WATER DISPLACED = (6.20' - 2.50') x 13.00' x 7.00' = 337 C.F. • j ' Q- ��, ,. ,� �,, ; ` r.. DATE: September 5, 2024 i�f;, ...� a :.,, 1 TEST PIT #: 1 WEIGHT OF DISPLACED WATER = 337 C.F. x 62.4 LB/C.F. = 21,029 LBS � ``.; j � !� j /.,;. j�',r w ��.,, `,�.� I, rr� �� � • 14, WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL LOAM, SUBSOIL AND UNSUITABLE WEIGHT OF 1,500 ! 500 GAL. 2-COMPARTMENT TANK = 33,500 LBS l %'•• ;rt +,"�'' i y ''`,� ,'/ ` ; ii _ -`. - . r „ MATERIAL IN AREA BENEATH AND FOR 5 FT. ON ALL SIDES OF LEACHING FACILITY. 1 - , 1 1 _ c.....-_._.:`?:�`'`•0 ELEV TOP = 10.70 SOIL COVER = (12.1 8.67) x 13,00 x 7.00 - 312 C.F.'S-- REPLACE ALL UNSUITABLE MATERIAL WITH CLEAN COARSE SAND FREE FROM CLAY, " ="`� `' ''` FINES OR OTHER UNSUITABLE MATERIAL IN ACCORDANCE WITH 310 CMR 15.255(5). WEIGHT OF SOIL ABOVE TANK = 312 C.F. x 110 LB/C.F. = 34,320 LBS ,;,;� `; y- ELEV WATER = 6.20' 33,500 + 34,320 = 67,820 LBS > 21,029 LBS; THEREFORE ACCEPTABLE ,$ LOCUS - ! 15. CONTRACTOR SHALL NOTIFY DESIGN ENGINEER OF ANY DISCREPANCIES FOUND IN PERC RATE < 2 min./inch F SITE CONDITIONS FROM THOSE SHOWN PRIOR TO CONTINUATION O WORK t s t/ * �./. , .' , >,` #.%! i ': „�- ;i ¢` ` ,�.. .* t` w; : DEPTH OF PERC = 4211- 6011 16. PROPOSED PROJECT IS LOCATED WITHIN: M _ _ ; . ,J', `: ASSESSOR'S MAP 31 LOT 90 ALARM 0 1/4" WEEP HOLE IN DISCHARGE PIPE � ;'�. ,,,• � ^ TEXTURAL CLASS: I - - • _..�. f OWNER OF RECORD: AMPLIFY HOLDINGS LLC I PUMP ON - HOISTING CABLE 7 x 19 STAINLESS t' 4' `? STEEL 1/8" DIA. / 1,760 LB. STRENGTH _ ADDRESS: 3172 NORTH RAINBOW BLVD PMB 7, 2" BALL CHECK VALVE SCH. 80 PVC 100 ' P.S.I. FLOWMATIC MODEL No. 208S MAP 31 r<` �` A`� (2) WIDE ANGLE CONTROL FLOATS LOT 87 1 l2411 (BARNES 073618) �o 2" SCH. 40 PVC DISCHARGE PIPE -. #i tr' s }f'_. r✓ „i '' 1: PUMP ON/OFF 120 ACTIVATION _ `,,�`<• '''"„�� fly ttP"'',w .`".;/ .^_�'7/� s*`t. ''•.� -'`'fix. .�``i B 2: ALARM ACTIVATION BARNES SE411 PUMP 0.4 H.P., 115 V ' �((^ {'y 111 2" DISCHARGE PASSING ' %4 ,\8 ERR-ipf 421/ 1-1/2 SOLIDS OR EQUAL G MAP 31 sit % /- k P i C 554" LOT 90 U ri ft r f /,14 ,�,' ..lt ,r .f�� `.0 601, N ;, '.A� NOT TO SCALE 12Z 10,133_ S.F. _�� ' Ip r ;�. I _, ;f � tit v � 78 ik .1 " 'f a`f .'' i' CNs rt LOCUS PLAN " _:�-��„_ ' SCALE: 1" = 1000' .. 1 �