Loading...
HomeMy WebLinkAboutEngineer PlanLEGEND SEPTIC COMPONENTS INSTALL 1500 GAL SEPTIC TANK (a EXISTING CESSPOOL DISTRIBUTION BOX TEST PIT O CLEAN OUT TO GRADE INSTALLER MAY MOVE VENT PIPE TO A DIFFERENT LOCATION. WATER LINE GAS LINE`ja= OVERHEAD WIRE on UTILITY yT POLE HYDRANT Q IINSTALLER TO VERIFY LOCATIONS OF ALL UNDERGROUND UTILITIES BEFORE EXCAVATING FOR SYSTEM. I I VENT PROPOSED SOIL I PIPE ABSORPTION SYSTEM -SEE DETAIL ON BACK I 5 S DAa1M ASSUMFI ELEVATION 54.09 A DEED RESTRICTION LIMITING THE DWELLING'S BEDROOM CAPACITY TO TWO SHALL BE RECORDED AT THE BARNSTABLE COUNTY REGISTRY OF DEEDS. TB-3 (UNWITNESSED) 1218124 0-8 FILL - B-12 Ap LOAM 10 YR 313 12-32 Bw L.S. 10 YR 416 32-120 C M.S 10 YR 614 \ t 48F47 46 5 150 ' 49 55 5 5; I 112 to h� I PINE.\ X 1 I 1 o\z c G� 9 MINI AL Q M GRAD G PROPOSE[ ��95'60V�IG OFtAWL ��®�®®� 50 m TOP 54.09 -0N O I WALL RETAINING L Oo T A AREA = 54.28 oc+- PLAN BOOK 7S PAGE 65 ASSR MAP 83 PCL 2 VARIANCES REQUESTED 310 CMR 15.2110) - SEPTIC TANK TO CELLAR WALL. 10 ft MIN REQUIRED - VARIANCE TO 8 ft SEPARATION REQUESTED. 310 CMR 15.2110) - SOIL ABSORPTION SYSTEM TO CELLAR WALL. 20 ft MIN REQUIRED - VARIANCE TO 10 ft SEPARATION REQUESTED. DAVID D. No. 1093 THIS IS A COLOR PLAN USE COLOR PLAN ONLY FOR INSTALLATION FULL DETAIL IS BEST VIEWED IN FULL COLOR 46 ABANDON EXISTING SEWER LINE AND REPLUMB AS SHOWN. ROBB YKES LIP—L A N OF No. 35498 SCALE: I in = 20 ft k valid for B� SYSTEM 10 20 ONIN, due to 5ta ar I septic variances. Boar) of Ilea{tpClyp[P1ni�91t51�;gR£ragltiS�,S for PRINT ON 8-112 x I yn tatare to PAPER FOR PROPER 4~ facilities 5 EXISTING CESSPOOLS IN NOT SHOWN ON THIS P LOCATED AND SHALL BE COLLAPSED AND FILLED. DAVID D. No. 461 Yarnuurlh Health Dcp:n lnu•nt INO ARE T" N 'PROVEI) 155 Geo Ryder Rd S Chatham. MA 02633 Ig SEWAGE DISPOSAL . SYSTEM PLAN -TO SERVE EXISTING DWELLING PRISCILLA ANDERSON OWNER(S) OF RECORD 8 PLEASANT AVENUE YARMOUTH. MA PROPERTY ADDRESS LOCUS MAP 9 4 1 PG. 1/ 2 JOBK SOIL TEST LOG SOIL EVALUATOR: DAVID D. COUGHANOWR. ASE #461 WITNESSED BY: BARRY LEWIS. HEALTH DEPT. TEST PIT 1 NO GROUNDWATER ENCOUNTERED - 2 MIN/INCH IN C SOILS ELEVATION 51.90 49.15 41.90 TEST PIT 2 NO GROUNDWATER ENCOUNTERED PERC AT 64 in — 2 MIN/INCH IN C SOILS ELEVATION 50.75 47.92 40.25 DEPTH INCHES SOIL HCNY20N USDA SOIL TEXTURE SOIL COLOR (MUNSELLI SOIL MOTTLES OTHER 0—B FILL 8-12 O LOAM 10 YR 2/2 NONE FRIABLE 12-lb A LOAMY SAND 10 YR 3/3 NONE FRIABLE Ib-33 B LOAMY SAND 10 YR A/6 NONE LOOSE 33-120 C MEDIUM SAND 10 YR 5/b NONE LOOSE DEPTH INCHES SOIL MONZON USDA SOIL TEXTURE SOIL COLOR (MUNSELLI SOIL MOTTLES OTHER D-10 FILL 10-14 O LOAM 10 YR 2/2 NONE FRIABLE 14-18 A LOAMY SAND 10 YB 3/3 NONE FRIABLE IB-34 B LOAMY SAND 10 YR 4/6 NONE LOOSE 34-126 C MEDIUM SAND 10 YR 6/3 NONE LOOSE 91500 GALLON SEPTIC TANK DIMENSIONS & DETAIL USE SHOREY ST-1500—H-10 I in 0 NOT TAPER TO �r SCALE 5 ft- 8 in /0 ft-6 in 5 E t INLET OUTLET COVER COVER FROM TO BUILDIL6, DO SEPARATION BETWEEN INLET & OUTLET TEES NO LESS THAN LIQUID DEPTH CROSS SECTION VIEW 3 IN DROP Al FLOW LINE 14 n in QUID GAS VEL BAFFLE in STONE BASE DISTRIBUTION BOA DB-BHO2DY DIMENSIONS PIPES EXITING D-BOX TO RUN LEVEL AND DETAIL FOR 2 FEET BEFORE PITCHING DOWN C 12 (n MIN 7_ as W C �. N TAONK r h b TO a. D ^ SAS \` 6 in STONE. BASE 21 In LY CROSS SECTION VIEW DESIGN CALCULATIONS DESIGN FLOW: 2 BEDROOMS X 110 GPD = 220 GPD SEPTIC TANK: 220 GPD X 2 DAYS = 440 GALLONS INSTALL NEW 1500 GALLON SEPTIC TANK. DISTRIBUTION BOX: INSTALL UNIT DEPICTED BELOW. SOIL ABSORBTION SYSTEM: THE LONG TERM ACCEPTANCE RATE FOR A CLASS ONE SOIL WITH A PERCOLATION RATE BELOW 5 MINUTES PER INCH = 0.74 GALLONS PER DAY PER SQUARE FOOT. THE 16 ft x 12 ft x 2 ft LEACHING GALLERY DEPICTED CAN LEACH: BOTTOM AREA = (16 x 12) = 192 sq. ft. SIDEWALL AREA = (16+16+12+12) x 2 = 112 sq. ft. TOTAL AREA = 304 sq. ft. FLOW CAPACITY = 0.74 x 304 = 224.96 gal/doy INSTALL A 16 ft x 12 ft x 2 ft GALLERY AS CONFIGURED BELOW. FLOW CAPACITY = 224.96 gal/day WHICH EXCEEDS THE 220 gol/doy REQUIRED FOR A TWO BEDROOM DESIGN. SOM ABSORP71ONN SYSTEM CONSTRUCTION DETAIL USE SHOREY PRECAST 500 GALLON LEACHING DRYWELL DRYWELL 16.0 ft UNIT m o mw o P (V N Lq L STONE 3.75 ft 8.5 ft 3.75 ft 500 GALLON DRYWELL DIMENSIONS & DETAIL INSTALL ONE INSPECTION RISER TO WITHIN THREE INCHES OF FINAL GRADE US4102 & INDICATE LOCATION H-ON AS -BUILT UN 36 in USE H-20 RATED UNITS n INSTALLER MAY SUBSTITUTE AN APPROVED GEOTEXTILE FABRIC IN PLACE OF THE 2 in. PEASTONE LAYER SPECIFIED. CROSS SECTION VIEW 2 in PEASTONE 2 in PEASTONE 28 3/4 in TO In 3/4 in T EFFECTIVE 26 in 1-1/2 in GRAVEL DEPTHTIVE I-112 in GRAVEL 1 III���IIILLLLLL 43 in 58 in 43 in 144 in -INSTALLER TO OBTAIN DI4'05AL WORKS PERMIT BEFORE STARTING WORK. -ALL COMPONENTS INSTALLED SHALL MEET THE MINIMUM REQUIREMENTS OF MASSACHUSETTS TITLE 5 SEPTIC CODE (310 CMR IS). -INSTALLER TO VERIFY LOCATIONS OF ALL UNDERGROUND UTILITIES BEFORE EXCAVATING FOR SYSTEM. -ECO-TECH RAPID RESPONSE RECOMMENDS THE INSTALLATION OF LOW FLOW FIXTURES & APPLIANCES. AND PERIODIC PUMPING OF THE SEPTIC TANK. -SEPTIC TANK NOT DESIGNED TO WITHSTAND VEHICULAR LOADING. DO NOT PARK OR DRIVE VEHICLES OVER SEPTIC TANK. ,. 0. : V V I P Rl O F L TOP OF FOUNDATION RAISE COVERS TO WITHIN ALL PIPE TO BE 4 in SCH. 40 PVC AND TO PITCH AT 1/8 in/ft MIN ', EL = 54.09-+-- - Z-m OF-F4N.AL GRADE 53.00 +Es2 q D-BOA USE H-20 3' UBE US 50.40 MAX u iEs 0������ RE 50.25T0 15O® GALLON t �LG�TrOC� ��a�� PRECAST DRYWELL — in 50.00 REFER TO DETAIL BOX "STONEa 6 in sroNE easE 2 ftDETAIL ABSORPMN �TC�-REFER TO BOX NO GROUNDWATER MOTTLING OBSERVED ;EWAGE DISPOSAL SYSTEM PLAN 8 PLEASANT AVENUE YARMOUTH, MA DECEMBER 9. 2024 FETE-' w 0 in BELOW