HomeMy WebLinkAboutEngineer PlanLEGEND 99 - EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. ALARM AND CONTROL PANEL SYSTEMPROFILE ® C -[991--- PROPOSED CONTOUR TO BE INSTALLED INSIDE [98.4 PROPOSED SPOT EL. BUILDING. ALARM TO BE ON (NOT TO SCALE) PROVIDE INSPECTION PORT WITH SEPARATE CIRCUIT FROM PUMP CONCRETE COVER TO WITHIN 6" GRADE 4" VENT, PERF. TH1 ALL WIRING TO CODE. RUNS OVER 2" PROVIDE CHARCOAL FILTER TEST HOLE 13.2 ACCESS COVER TO FIN. GRADE PROVIDE QUICK DISCONNECT FOR PUMP DRILL LAST HOLE IN EACH LATERAL ON TOP TO VENT AND INSECT SCREEN r TOP FNDN. EL.= 2.�. SLOPE OF GROUND 11.0' MINIMUM OF COVER OV 1 z AIR WHILE LATERAL FILLS FEMALE ADAPTOR & THREADED PLUG 2"0 .75' RECAST _j_11 95' THREADED END CONNECTION UTILITY POLE ::= PRECAST H-10 2" PRESSURE LINE s�Rs (TYP.) SCH 40 PVC 2SLOPE TO DRAIN BACK 1/4" SHIELDED �1'17 FIRE HYDRANT I FLOAT SWITCH 8.92 INV. ORIFICES f --- : , 11.0' NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING .- :.�10" *�091 2000 GAL r ST/PC , 2204 GAL RESERVE a SETTINGS: ALARM ON Do o� 0�0 00 p �---Q----g 0 0 � 2" INVERTS CfJ Oo J LEVEL AT 11.0' 9.17' r _ ---- _ _ _o -- _ --_-- BOTTOM ! EACHING�E�/EL AT EL. 10.5' 14" PUMP ON ZABEL FILTER TEE :.: 0 5" WORKING RANGE 5" 2" END MANIFOLD OUTLET TEE W EXTENSION / .' 1500 GAL COMP. PITCH TO DRAIN BACK TO CONNECT ENDS 4' LIQUID LEVEL 12" PUMP OFF PUMP CHAMBER- NO LOW SPOTS. 5.0' *THE INSTALLER SHALL VERIFY THE �'•� �'' ` '"�' ""'' 4. 3/4" TO 1 1/2" DOUBLE WASHED STONE LOCATIONS OF ALL UTILITIES AND ALL o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 o 0 WEEP HOLE BUILDING SEWER OUTLETS AND °o°o0° o°o°o°o°o°o°o CHECK VALVE SIDE ELEVATION VIEW ELEVATIONS PRIOR TO INSTALLING ANY Z 6" BAFFLE MYERS SRM 4 PORTION OF SEPTIC SYSTEM 6" CRUSHED STONE OR MECHANICAL SUBMERSIBLE 4/10 HP PUMP ADJUSTED GROUNDWATER EL. 5.5 COMPACTION. (15.221 [2]) SYSTEM (OR EQUAL) (1.7' FROM ENCOUNTERED GROUNDWATER) (ON BLOCK) BUOYANCY CALCS: H-10 2000 GAL. DUAL COMP. SEPTIC TANK WEIGHS 20,000 LBS 2.51 x 12.0 x 6.5 X 62.4 = 12,217 LBS UP (OK) (2•9% SLOPE) DUAL COMPARTMENT FOUNDATION 59' SEPTIC TANK/ 9' LEACHING FACILITY PUMP CHAMBER 1 /4"o HOLE AT 5' O.C. ALTERNATE BETWEEN TOP & BOTTOM OF PIPE. EXACT DIAMETER HOLES SHOULD BE SHOP DRILLED WITH A DRILL PRESS TO ENSURE UNIFORMITY. REMOVE BURRS PRIOR TO PLACING PIPE. 2.0" 0 SCH-40 PVC LATERAL SNAP -ON C SHIELD DRAINAGE SLOTS ORIFICE SHIELD OS200 ORENCO SYSTEMS INC PH. 1-800-348-9843 OR EQUAL. ORIFICE SHIELD DETAIL NOT TO SCALE 1 • • ENGINEER: CRAIG J. FERRARI, SE #13871 WITNESS: BARRY LEWIS DATE: 9/26/24 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS ® UNSUITABLE SOIL Q ELEV. 1 0" 11.0' A LS 1OYR 4/2 12" LS 1OYR 5/8 20" ///// 9.3' C1 PERC 2" PRESSURE M/CS LINE BACK TO PUMP G-W ADJ. DATA: 2.5Y 7/4 WELL: MIW-29 2" MANIFOLD ZONE: B ADJ: 3.3' SEPT 2024 120" 1.0' GROUNDWATER ENCOUNTERED @ 87" EL. 3.8' 1 � t 1 � � X- PROVID OF 40 MIL LINER AT 5' OFF AS I EA SHOWN. TOP AT E 11.17', t�TTOM A\ ; 8 .17 ' PROP. VENT WTI 'CHAARCOAL FILTER AND BUGSCREEN (FINAL PL)kCEMENT BY CONTRACTOR WITH OMEOWNER CONSULTATION) O 11 gRDE TREECINE / N�o �C o WOOD POST 5' REMOVAL OF UNSUITABLE SOIL REQUIRE N AROUND PERIMETER OF LEACHING FA IITY, Y DOWN TO SUITABLE SOIL LAYER. RE WITH CLEAN MED. SAND, TO MEET SPECIFICATIONS OF 310 CMR 15.255(3) INSPECTION PORT 30.0' CLEANOUT (TYP.) 5.0' o U < toO< CV < 0 L6 VENT LEACHING DETAIL (SCALE: 1 "=10') LOT AREA: 10,315 f S.F. 0.24 t AC._ 1.3.0 A& E<<Nc , PAVED -` DRIVEWAY ,.� SEE S NOTE 16 �� 12 CON C � lST/N�. ATE \\\ \ GgRgGE W ISTINC \ f� jLAg CLEANOUf 8(TYP.) I715 T O.F Y� NEDGE ` 13.2, x G 56.50 11 o F DEN BENCHMARK: BULKHEAD COR. =12.6' NAVD88 LIVING ROOM BEDROOM KITCHEN = ti BEDROOM m EX/STI.NG FLOOR PLANS (NOT TO SCALE) VARIANCES REQUESTED: UNDER TOWN OF YARMOUTH HEALTH REGULATIONS: - 50% OF THE REQUIRED GROUNDWATER ADJUSTMENT (3.3' TO 1.7') 20 uj w 1s z 0 w to 0 5 NOTES 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-11 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED BENEATH AND 5' AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. 13. OWNER'S ENGINEER TO PERFORM INSPECTIONS OF THE FINAL INSTALLATION. MINIMUM OF 24 HOURS NOTICE REQUIRED. 14. INSTALLER TO VERIFY THE ELECTRICAL SYSTEM IS SUITABLE FOR PUMP CONNECTION. ELECTRICAL PERMIT REQUIRED. 15. ACCESS FOR ROUTINE MAINTENANCE MUST BE PROVIDED FOR ZABEL FILTER. INSTALLER MUST FOLLOW MANUFACTURER'S SPECIFICATIONS FOR PROPER FILTER INSTALLATION, INSTRUCT OWNER ON MAINTENANCE. 16. SAWCUT & PATCH PAVEMENT AS REQ. 0 25 50 75 100 CAPACITY - GPM PUMP CURVE FOR MYERS SRM4 4/10 HP PUMP ,,. 1. e V"''°� DANIELA.�'r I^fie I�f�rslF�e r: a 4 P `� CIVIL ! nki i r 1 i"; Est 4 ;:c.4 ✓9$0 g �A a A p �,zC r,R ---------- 0'���C�srE��`�os���,�. g,_....e.._.�. r � � DATE DANIEL A. OJALA, P.E., P.L.S. LOCUS MAP SCALE 1 "=2000'f ASSESSORS MAP 32 PARCEL 187 LOCUS IS WITHIN FEMA FLOOD ZONE X (AREA OF MINIMAL FLOOD HAZARD) AS SHOWN ON COMMUNITY PANEL #25001CO588J DATED 7/16/2014 SITE IS WITHIN MASSDEP DESIGNATED NSA SYSTEMIL A GARBAGE DISPOSER IS NOT ALLOWED EXISTING 2 BEDROOM DWELLING DESIGN FLOW: 2 BEDROOMS ® 110 GPD = 220 GPD USE A 220 GPD DESIGN FLOW SEPTIC TANK: 220 GPD (2) = 440 USE A 2000 GAL. DUAL COMPARTMENT SEPTIC TANK LEACHING: 330 GPD (.74) = 446 SF REQUIRED 15' X 30' = 450 SF OK 450 SF X .74 = 333 GPD OK USE A 15' X 30' PRESSURE DOSED LEACHING FIELD Permit valid for RF,PAIR OF S!:PTIC SYSTEM ONLY, due to State and Local septic variances. Board of Ifealti, resie" and approsal is required for Nary future add,tionsircnosations/a iterations to sewage facihtics :rr„t/or structures/dsselling. l"a►ornntk� flealth Department ' �ROVED Date �J0 3 � N 9i �av rv;na..a �'w ,re. �4• h�^i, .. �1, _1♦'F 2 PREPARED FOR 2-uz Tif Nff �►:. DATE: OCTOBER 7, 2024 Scale:1 "= 20' 0 i0 20 30 40 50 FEET off 508-362-4541 fax 508-362-9880 downcape.com civil engineers land surveyors 939 Main Street ( R to 6A) YARMOUTHPORT MA 02575 SURVEY: QAH DRAFTED BY: PTT CHECKED BY: DID 24-246 BOUDREAU 2.DWG a ICE #24-246