Loading...
HomeMy WebLinkAboutEngineer PlanACCESS COVERS MUST BE WITHIN 9' MINIMUM. 6' OF FINISH GRADE 3' MAXIMUM COVER 1/0.82 FIRST 2' TO BE� LEVEL MIN 2' OF PEASTONE ,DIdU A/OC �F-�i ' 3/4' - I I/2' DIA. 0 04.82 104.2± 103 :f] DOUBLE WASHED STONE 04.5± 103.7�0 o /p2 9 0 /00.9 OUTLET 2-500 GAL LEACHING CHAMBERS 1000 GAL -BOX W/4' STONE AROUND. 12.8'F x 25'1 x 2'd SEPTIC TANK lFXiST1NGl 6' CRUSHFn .STONF nR LOCUS - LOCUS MAP INVERT ELEVATIONS: INVERT AT BUILDING: 104.82 INVERT /N SEPTIC TANK: 104.51 INVERT OUT SEPTIC TANK: 104.2± INVERT IN DIST. BOX: 103.67 INVERT OUT DIST. BOX: 103.5 INVERT IN LEACH CHAMBER: 102.9 BOTTOM OF LEACH CHAMBER: 100.9 ADJUSTED GROUND WA TER : N/A OBSERVED GROUND WATER: N/A BOTTOM OF TEST HOLE #1: 95.9 N DESIGN CRITERIA: DESIGN FLOW: 3 BEDROOMS AT 1/0 G.P.D. PER BEDROOM EOUALS 330 G.P.D. NO GARBAGE GRINDER SEPTIC TANK REQUIRED: 330 G.P.D. X 200V - 660 GAL. SEPTIC TANK PROVIDED: 1000 GAL EXISTING SOIL ABSORPTION SYSTEM REQUIRED: DESIGN PERC RATE C 5 MIN/INCH SOIL TEXTURAL CLASS - I EFFLUENT LOADING RATE - 0.74 GPD/SF 330 GPD / 0.74 GPD/SF - 446 S.F. REOUIRED PROVIDED: 2-500 GAL LEACHING CHAMBERS W/4' STONE AROUND. A-471 S.F. 471 S.F. x 0.74 - 348 G.P.D. SOIL TEST PIT DA TA INDICATES v_ INDICATES PERCOLATION OBSERVED TEST GROUNDWA TER GENERAL NOTES. I. THIS PLAN IS FOR THE DESIGN AND CONSTRUCTION OF THE SEWAGE DISPOSAL SYSTEM ONLY. 2. VERTICAL DATUM /S ASSUMED. FOR BENCH MARKS SET. SEE SITE PLAN. J. ALL CONSTRUCTION METHODS AND MATERIALS AND MAINTENANCE OF THE SEPTIC SYSTEM SHALL CONFORM TO MASS. D.E.P. TITLE 5 AND LOCAL BOARD OF HEALTH REGULATIONS. 4. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER THAN 3' IN DEPTH SHALL BE CAPABLE OF WITH- STANDING H-20 WHEEL LOADS. 5. ALL SEWER PIPE SHALL BE SCHEDULE 40 OR APPROVED EQUAL. 6. SEPTIC TANK AND D-BOX SHALL BE REINFORCED PRECAST CONCRETE AND WATERTIGHT. D-BOX SHALL BE WATER TESTED FOR LEVEL WHEN THERE IS MORE THAN ONE OUTLET. 7. BEFORE CONSTRUCTION CALL 'DIG -SAFE- TP fl . 1 -888-DIG-SAFE AND THE LOCAL WATER DEPT. HORIZON TEXTURE COLOR FOR LOCATION OF UNDERGROUND UTILITIES. 0'' 106.9 FILL 8. EXISTING LEACH PIT TO BE PUMPED DRY AND. 10 106.1 BACKFILLEO. A LOAMY IOYR SAND 2/2 9. EXISTING SEPTIC TANK TO BE INSPECTED FOR THE 14 ' .... •..................................... 105.7 CONDITION OF THE TEES/BAFFLES. REPLACE IF B LOAMY IOYR NECESSARY. SAND 3/6 24 ' ......................................1... 104.9 C I MEDIUM 2.5Y SAND 6/6 42` 112 132 ' NO WATER 95.9 DATE: OCTOBER 17. 2002 TEST BY: STEPHEN HAAS WITNESSED BY: AMY VONHONE PERC RA TE: C 2 MIN/INCH %4 `z AI SEPTIC SYSTEM LEES/G/V 36 L 0/VOFEL L OW DR / VE. MAP / S / PARCEL 7-5. / PRE -PA RED FOR : 0 Eit 4 4 2 C 32 E S THE P S C O T 7- 1_ - _r""jh' " P 0. BOX .2-5. YARMOCJTHPOR T. MA 02675 SCALE : / " - 20 ' OCTOBE-R 00. 2002 E A G L E SURVEY I NO , I NC 923 Route 6A Ya rm(=>u t h p o r t MA 02675 ram/ jj;l��/lip (508) 362-8 1 32 C508-) 432-5333 0 10 20 40 JOB N0: 02- I l2 FIELD: OLS CALC: SAH CHECK: CF9' OR,N: SAH