Loading...
HomeMy WebLinkAboutEngineer PlanGENERAL NOTES 1. ALL PRECAST COMPONENTS TO BE H-10 RATED. ALL COMPONENTS WITH ANY ANTICIPATED VEHICULAR TRAFFIC TO BE H-20 RATED. 2. THE DESIGN OF THIS SYSTEM DOES NOT ALLOW FOR THE USE OF A GARBAGE GRINDER. 3. MUNICIPAL WATER IS AVAILABLE. 4. ALL CONSTRUCTION TO CONFORM WITH 310 CMR 15.000 AND ALL OTHER APPLICABLE LOCAL, STATE AND FEDERAL CODES AND REGULATIONS, 5. INSTALLER/CONTRACTOR TO REVIEW & VERIFY ALL ELEVATIONS AND DETAILS AND REPORT ANY DISCREPANCIES TO DESIGNER PRIOR TO CONSTRUCTION OR ASSUME ALL RESPONSIBILITY. 6. INSTALLER/ CONTRACTOR IS RESPONSIBLE FOR MAINTAINING SAFE WORK AREA, VERIFYING ALL UTILITIES AND NOTIFYING "DIG SAFE" (1-888-344-7233) 72 HOURS PRIOR TO CONSTRUCTION. Z ANY CHANGES TO OR DEVIATIONS FROM THIS PLAN MUST BE APPROVED IN WRITING BY FLAHERTY ENVIRONMENTAL SERVICES AND LOCAL BOARD OF HEALTH. 8. FINISH COVER OVER COMPONENTS IS NOT TO EXCEED 3' PER 310 CMR 15.000 UNLESS SHOWN PER PLAN. 9. ALL ABANDONED SEPTIC SYSTEM COMPONENTS TO BE PUMPED DRYAND FILLED WITH CLEAN SAND OR REMOVED AND REPLACED WITH CLEAN SAND, 10.ALL COMPONENTS TO BE PROVIDED WITH WATERTIGHT ACCESS PORTS WITHIN 6" OF FINISH GRADE. 11,ALL SEPTIC TANKS, DISTRIBUTION BOXES AND PIPING TO BE INSTALLED WATERTIGHT. 12. NO KNOWN WETLANDS OR WELLS WITHIN 150 FEET OF PROPOSED LEACHING EXCEPT AS SHOWN. 13, THIS IS NOT A CERTIFIED PLOT PLAN AND UNDER NO CIRCUMSTANCES IS THIS PLAN TO BE USED FOR ZONING OR BUILDING PURPOSES. 14,LOT IS SHOWN AS ASSESSOR'S MAP 118 PARCEL 24 . 1�: LOCUS PROPERTY'S PROPOSED SYSTEM APPEARS TO BE WITHIN AN AQUIFER PROTECTION DISTRICT (ZONE II). DESIGN CALCULATIONS NUMBER OFACTUAL BEDROOMS 3 GARBAGE DISPOSAL UNIT NO TOTAL ESTIMATED FLOW (110 GAL/BR/DAYX3 BR) 330 GAL./DAY REQUIRED SEPTIC TANK CAPACITY 660 GAL. SIZE OF SEPTIC TANK SOIL CLASSIFICATION DESIGN PERCOLATION RATE EFFL UENT L OADING RATE LEACHING AREA (2) x (25.0' + 12.83)(2) = 151 SF 25.0' x 12.83' = 320 SF 471 SF x 0.74 = 348 GPD 1000 GAL. (EXISTING) 1 <2 MIN./INCH(ASSUMED) 0.74 GAL./DAY/FP USE (2) H-20 500 GALLON CHAMBERS WITH 4' STONE INA 12.83'X25.0'CONFIGURATIONASDIAGRAMMED RESERVE LEACHING CAPACITY N/A TEST HOLE #1 Evaluator: David D. Flaherty Jr., RS SE# 2755 BOHWitness: BartyLeWs, BOH Date: October31, 2024 TH-1 ELEV. 75.0' 0"- 11" 11-- 120- G.W. ELEV. N/A SOIL EVALUATION Flaherty Environmental Services P. 0. Box 331 SYSTEM DETAIL Harwich, MA 02645 774.994.1166 (NTS) 25' 0 0 12,83' �. �F24 7 certify that on November 12, 2002, I have passed the examination approved by the Department of Environmental Protection and that the above analysis s has been performed by me consistant with the required training, expertise, and experience described R'l ') in 310 CMR 15.018(2)." 2.1 l.1 T J r.�A4',��t/(/ SITE AND SEWAGE PLAN FOR B & B CONSTRUCTION, INC./ 1EANINE JANVIER 4 OLD COLONY WAY SOUTH YARMOUTH, MA BOTTOM TH-1 ELEV. 65.0' PAGE 2 OF2 DATE: 111212024