Loading...
HomeMy WebLinkAboutConstruction Details-D-4EROSION CONTROL DETAILS D-4 PERMITS NO. DATE COMMENT THESE DRAWINGS ARE THE PROPERTY OF THE DESIGN ENGINEER, GREEN SEAL ENVIRONMENTAL, LLC. UNAUTHORIZED REPRODUCTION FOR ANY PURPOSE IS AN INFRINGEMENT UPON COPYRIGHT LAWS. VIOLATORS WILL BE SUBJECT TO PROSECUTION. DIMENSIONS ARE AS INDICATED. USE OF THIS PLAN CONSTITUTES ACCEPTANCE OF TERMS AND CONDITIONS SET FORTH IN ACCOMPANYING PROJECT DOCUMENTATION. IT IS THE RESPONSIBILITY OF THE USER TO CONFIRM DISCREPANCIES WITH THE ENGINEER PRIOR TO USE. 228 ROUTE 28 YARMOUTH, MA CONSERV GROUP PURPOSE: LOCUS: PREPARED FOR: DRAWING TITLE: CAD TECH:CHECKED BY: ENGINEER:DATE: SCALE: SHEET: REVISIONS MW 02/28/2024 SDC JDO GREEN SEAL ENVIRONMENTAL, LLC 114 STATE ROAD, BUILDING B SAGAMORE BEACH, MA 02562 TEL: (508) 888-6034 FAX: (508) 888-1506 WWW.GSEENV.COM NONE LOCUS MAP NOT TO SCALE SITE 7'-6" (TYP) 6' - 0 " 0' - 6 " TY P SECTION B-B PLAN CONCRETE WASHOUT 4" * 50' MINIMUM LENGTH 10 ' M I N . 10 ' M I N . 10 ' M I N . WI D T H 10' MIN. 3' * 50' MINIMUM LENGTH MI N I M U M 6 " O F 2 " - 3 " AG G R E G A T E O V E R LE N G T H AN D W I D T H O F ST R U C T U R E 20' PAVED APRON PLAN VIEW PROFILE STABILIZED CONSTRUCTION ENTRANCE NOT TO SCALE LOAM AND SEED NOT TO SCALE CURB INLET PERSPECTIVE VIEW NOT TO SCALE SECTION PLAN PLAN SILTATION BARRIER NOT TO SCALE INLET PROTECTION NOT TO SCALE 12 " M I N . CONCRETE WASHOUT STATION NOT TO SCALE TEMPORARY CONSTRUCTION FENCE NOT TO SCALE EROSION CONTROL AT CATCH BASIN NOT TO SCALE CONCRETE WASHOUT SIGN DETAIL (OR EQUIVALENT) 36 " 36 " 2" 8" 10' MINIMUM VA R I E S VA R I E S PE R PL A N 4" M I N CO N C . B E D D I N G 14 14" 12" 4" S L A B T H I C K N E S S 9" TRENCH DRAIN DETAIL NOT TO SCALE SECTION A-A CROSS SECTION ISOMETRIC