HomeMy WebLinkAboutBLDE-25-134 load calculation Elliott, Ken From: JACK GRIFFIN ELECTRIC <jackgriffinelectric@comcast.net> Sent: Wednesday,Janua 2 025 12:22 PM To: Elliott, Ken Subject: Fwd: load calc f r 23 Elmcroft �� 2�j - �4 Attention!:This email originates outside of the organization. Do not open attachments or click links unless you are sure this email is from a known sender and you know the content is safe. Call the sender to verify if unsure. Otherwise delete this email. Get Blue Mail for Android On Jan 28, 2025, at 5:43 PM,jackgriffinelectric@comcast.net wrote: Hi Ken Here is the load calculation you requested. Thank Jack 978-479-2521 Question: 3000 square foot house • 1 A/C unit, minimum circuit amp: 18 • 1 A/C unit, minimum circuit amp: 13.8 • 1 A/C unit, minimum circuit amp: 8.7 • 1 Electric dryer • 1 Washer • 1Oven i • 1 Dishwasher • 3 Air handlers, 5 amps each, 240 volts • 1 Gas boiler • 1 Car charger, 40 amps, 240 volts Use the 2023 NEC Alternate Method to determine the required service size. Step-by-Step Calculation: 1. General Lighting and Receptacle Load: • 3000 sq. ft. x 3 VA per sq. ft. (as per NEC 220.12): 3000 x 3=9000 VA 2. Small Appliance Circuits: • Two required small appliance circuits (NEC 220.52(A)), each at 1500 VA: 2 x 1500=3000 VA 3. Laundry Circuit: • One laundry circuit at 1500 VA (NEC 220.52(B)): 1500 VA Subtotal = 9000 + 3000 + 1500 = 13,500 VA 4. Apply Demand Factor(First 10 kVA @ 100%, remainder @ 40%): • First 10,000 VA: 10,000 VA @ 100% = 10,000 VA • Remaining: 13,500 - 10,000 = 3,500 VA @ 40% = 1,400 VA Total General Load = 10,000+ 1,400 = 11,400 VA 5. Fixed Appliances: • Dishwasher: 1200 VA(assumed typical load) • Electric Dryer: 5000 VA (minimum per NEC 220.54) • Oven: 8000 VA (assumed standard load) • Washer: 1200 VA (assumed typical load) • Air Handlers: 3 units x 240V x 5A= 3600 VA Subtotal Fixed Appliances = 12,200 + 3600 = 15,800 VA 2 6. Demand Factor for Appliances: Apply 75%demand factor for 4 or more appliances (NEC 220.53): 15,800 VA x 75% = 11,850 VA 7. HVAC Loads: • Largest A/C Unit Only (per NEC 220.82(C)): 18A x 240V=4320 VA The two smaller units (13.8A and 8.7A) are not included, and the gas boiler is ignored since it's not electric. HVAC Total =4320 VA 8. Car Charger: • 40A x 240V =9600 VA Final Load Calculation: 1. General Load: 11,400 VA 2. Fixed Appliances: 11,850 VA 3. HVAC Load: 4320 VA 4. Car Charger: 9600 VA Total Load = 11,400 + 11,850+4320 + 9600 =37,170 VA Convert to Amps: • 37,170VA_ 240V= 154.88A Service Size: Round up to the next standard breaker size: 200A service required. 3 i