HomeMy WebLinkAboutHERSRECEIVED JAN 31 2025 laaa AUILDING DEPARTMENTBv --.- TARGET INSPECTIONS SUMMARY OF TOTAL DUCT LEAKAGE TESTING RESULTS FOR: Heating & Cooling Concepts Site Located at: 81 Winslow Gray Road West Yarmouth, MA Project Number: 225E Duct Test Report Version: 1.0 Target lnspections Steven Grevelis P.O. Box 444 West Dennis, MA 02670 Phone: (888) 280-2108 Email: steve@targetinspections.com www.targetinspections.com Certified HERS Rater (RlN - 4958795), BBRS Approved Third Party Tester (Documents Available on Request), & Microbial Professional Enclosures: Summary of Results PASS Based on testint of the total duct systems, the observed total duct leakage at the time of testing of the system was at or below the allowable limit (4 cfm per 100 sq ft) as set forth in IECC 2021 with tested results of 3.96 cfm per 100 sq ft. Copynght 2010i 2011Summary of Tesling Results Page 1 of 5 Target lnspeclions TARGET INSPECTIONS Testing Conditions September Lzth,2023 Wlnd-SW@3MPH Weather - Cloudy Outdoor Temperature -740 F Outdoor Relative Humidity - 91% Barometric Pressure - 29.9O" Page 2 of 5 TARGET INSPECTIONS Total Duct Leakage Test Test Date: 09/72/2023 Technician: Noah Grevelis Test File: 225E_Heat Cool_81 Winslow Gray Rd_W yarmouth Duct Building Address: 81 Winslow Gray Road West Yarmouth, MA Equipment Used Retrotec - DU-200 Duct Blaster w/ DM32 Manometer Serial Nu m bers: FI9O\O67 4 I 404468 DM32 Factory Calibration Date: 1O-23-2020 DM32 Next Factory Calibration Date by-. tO-23-2O25 Field Calibration of DU-200 Performed: O3-2L-2O24 Tubing lntegrity Testing Performed on Site The home has 1 system outside of conditioned space that was tested: Test Results ln accordance with IECC 2021 the maximum allowable total duct leakage is 4 cfm per 100 sq ft at +/- 25 pa in the rough or final stage. Currently MA Stretch Code Towns must meet the same requirements. Square footage of condationed space as 1693.4 square feet: - Maximum allowable leakage of 4 cfm per 100 sqft=57.72 cfm: (4 cfm x 1693.4 sq ftl 100 sq ft = 67 .72 cfml System #1 - Servicing the basement and first floor - - Tested total duct leakage was 57.13 cfm @ -25 pa Total duct leakage was 57.13 cfm = 3.96 cfm per 100 sq ft cfm = cubic feet per minute pa = pascals sq ft = square feet Iargel lnspeclions Summary of Testing Rosults Page 3 of 5 copyrght 2010/2011 Conclusion Based on-testing ofthe total duct systems, the observed total duct leakage at the time oftesting of the system was at or below the allowable limits (4 cf m per 100-sq ft) as set forth inlECc 2021 with tested results of 3,96 cfm per 100 sq ft. The total duct leakigi was 67.13 cfm =3.96 cfm per 100 sq ft. The system as installed meets the recommended guidelines and no further sealing is required. Note 1: Square footage provided by Heating & Cooling Concepts. TARGET INSPECTIONS Copyrrght 2010/2011 Setup of the tested system.Manometer reading of the tested system. Target lnspections Summary ol Tesrrng Resulls Page 4 of 5 -rI--@ .26,4 t V 15l I ILlI 67.t3T AtroP ) PHOTO SUMMARY PHOTO SUMMARY This inspection report is sotety based on the conditions within the defined .r". .r,h;iffXJiilr;:.:,",J; only and makes no express or implied warrant or guarantee as to future changes in condi|on or conditions outside of the described job scope. Sincerely, Steven Grevelis Certified HERS Rater (RlN - 495879S), & Certified Microbial Professional Page 5 of 5 l** A^i-