Loading...
HomeMy WebLinkAboutSeptic plan 7.31.2024Permit valid for REPAIR CIF S ' TIC SYST ON! 1 , due to State and Local septic var' R,�,ir i „t IIeaIIh review and appr vaI is req:i for .,w, owre additions/renov ions/hers to ,cwagc 1. ililivs and/or struct es/dwelling.t�� Z g a z {�— w d Cn _z W Q C7 0 < W ti- w w L, n Li 0 PO Z Lr) `o ry < 1 U U 0- QOQ Z W W O J V) Q I- I- Lj I- ID° to W ® fl C) w LLJ LLI a 0 CY 01- tY Q� Lr w w U U U Z Q Q Q 014 Pe) 1'k-1m)n1111 UTILITY POLE Depart nt I VE� , O �4 oy D t, GRAVEL DRIVEWAY / 1 1) TEST HOLE #1 ELEV = 7 80 I eS� PORCH 40 MIL POLYETHYLENE LINER ALONG INSIDE OF STRIPOUT ALONG FOUNDATION WALL FROM ELEV. 7.5 to 3.5 2' GROUNDWATER REDUCTION CREDIT FOR PRESBY LEACH FIELD—DEP APPROVAL ATTACHED. NOTE: —NATURAL GAS LINE TO BE RELOCATED ' NOTE: —WATER LINE TO BE RELOCATED EXISTING 'a 0 4 BEDROOM .0 �) 8� � )y HOUSE r / TOF= ELEV. 7.63 o(�Hydrant. EXIST. I IIJE # 16 1�0 gal. Septic an & SAS CRAWL SPACE FND. DECK TO BE ABANDONED BLOCK FND ON GRADE VENT LJ J3 m 0 a O O L / J EXI T. S �4 Sea g 0 20 40 50 SCALE: 1 "=20' moo' v AE-12 FLOOD ZONE � � 4 NEW A 000 gal. SHED cr'MOVED L 2,020 Sq are Feet r� 5 FOOT STRIPOUT ALL AROUND Note: Remove soil down to el. 5.30 fit: replace with clean coarse sand w/perc, rate less than or or equal to 2 min,/in. before & after placement `-NEW 1500 gal. Septic Tank WITH FAST 0.5 Low Profile H-10 STONE101 FN D O� & RECEIVED f SEf' 25 2021 (• 16 Gulls Cove Road, Yarm... x Millennium floonn Q �'�NsH'�DC�^r;:cc rpe r, Q �` Gci1Ro a Live 16 Gulls Love Rd { GENERAL NOTES 1. Contractor is responsible for Digsafe notification, Verification of Utilities and protection of all underground utilities and pipes. 2. The septic tank and distribution box shall be set level on 6" of 3/4"-1 1,/2" stone. 3. BackfilP should be clean sand or gravel with no stones over 3" in size. 4. This system is subject to inspection during installation by Carmen E. Shay -Environmental Services, Inc. 5. The contractor shall install this system in accordance with Title V of the Massachusetts state code, the approved plan and Local Regulations. 6. If, during installation the contractor encounters any soil conditions or site conditions that are different from those shown on the soil log or in our design installation must halt & immediate notification be made to Carmen E. Shay - Environmental Services, Inc. 7. No vehicle or heavy machinery shall drive over the septic system unless noted as H-20 septic components. 8. Install Tuf-Tite gas baffles or equals on all outlet tee ends, 9. All Distribution Lines shall be 4" diameter Schedule 40 NSF PVC pipes. 10. All solid piping, tees &fittings shall be 4" diameter Schedule 40 NSF PVC pipes with water tight joints. 11. Municipal Water is Connected to ALL OF The Residence and Abutting Properties. THE PROPERTY LINES ARE APPROXIMATE AND COMPILED FROM THE SURVEY PLAN BY RONALD J. CADILLAC, PLS, RS ENTITLED: "EXISTING C0NQdTIONS PLAN-16 GULLS COVE RD YARMOUTH, MA" DATED MARCH 21, 2005 AND IS NOT INTENDED TO BE A SURVEY PLOT PLAN IT SHOULD BE USED FOR NO PURPOSE OTHER THAN THE SEPTIC SYSTEM INSTALLATION. EXISTING TANK & SAS TO BE PUMPED OUT AND ABANDONED IN PLACE NOTE: ANY STRIPPED OUT SOIL CONTAINING LEACHATE FROM THE EXISTING SAS TO BE DISPOSED OF AS PER BOARD OF HEALTH SPECIFICATIONS. PACT PLAN OF PROPOSED SEPTIC SYSTEM UPGRADE PREPARED FOR AhJITA SCABBY 16 GULLS ATCOVEROAD PARCEL !Q: 1 T-157 WEST YARMOUTH, MA PREPARED BY: I N ENYIRONMENTAL ,SERVICES A` "o_,, Box 1576 � MASHPEE, MA 02649 Gist fiP� TEL/FAX 508-294-7498 DRAWN BY: CES DATE: DULY 31, 2024 PROJECT#16 GULLS COVE FILENAME: 16 GULLS COVE.DWG SHEET 1 OF 2 *NOTE: ALL PIPES ARE TO BE 4" SCHEDULE 40 P.V.C. 10° min. fO from ��}1 t{ it Se1,�ptic *_ Grode over Septic TW*/PU p Chanbr -7.35 .e.-• ... i Existing Foundation I{li Provide Risers if necessary f 5, 20' TOP OF FOUNDATION ELEV. 8.45 to bring Septic tank cover's Provide Risers if necessary D-SOX cover must must have riser and be a_ To finished grade to bring PUMP CHAMBER within 6 in. of finished grade over SAS -6.25 ON TITLE V CERTIFIED SAND AS SHOWN OUT COVER TO GRADE Crud. ovw D-Box -6 25 INSPECTION PORT 4" PVC (CAPPED) INSPECTON PORT TO fiE CENTER w T to 6" OF GRADE PRESBY E14MRO SEPTIC PIPE 12 Rows of 30 a51. Box S=LE TOP OF Lsach Field - 7.So LEACH FIELD CROSS-SECTION EXIST. PIPE S veer"Li Oter 15 O.Oi or Great FROM EXIST. FOUNDATION O a 1 FT_ Q0? 15 ti" :• �''_ ...o` ```:z�Z r:`:,-,.;: irY NEw FAST O.sD NEW M us :-:>•. z ,_ . x p o ;.,. 500 GAL I/AUDtTI1TE 1000 GAL. r n o0 am Bott of each Facility Elev.=6.50 CONCRErE FULL N ASr In 0.5D NIT tPUMP u u LEACH FIELD w�® T CHAMOBER o' ; 0' 3.0' PROVIDED H-20 ; 11 n b a z o c _c'------- ____ ----ESHWT ELEV.=3.43 > 6 in.of 3/4"-1 1/2" 6 in.of 3/4"-1 1/2" o c ,3 compacted stone 5 6 in.of 3/4'-1 1 2 STRFPOUT-5 FEET ALL AROUND PROPOSED SAS ADJUSTED ESHWT - ELEV.=3.43 fWOBSG1M - O 6- Weeping-(62" .8' d justm ELEV.-2.63 z compacted stone S c / . replace with GROUNDWATER OBS. O 62" or ELEV.-2.63 MIW 29 ZONE A -MAY 2024= 0.8' Adjustment NEW compacted stone Note: Remove soi down to N. 5.30 h dean worse *and w/perc. rate Ion than or Bottom of Test Hole = Elev.-(-2.20) ESHwr - 5.4' or ELEV.-3.43 1500 GAL m SYSTEM PROFILE Test Hole Elev.--2.20 or woof to 2 min./in. before & after placement Bottom of T= FAST 0.50 I/A DENITE SYSTEM ( ) SEPTIC TANK Not to Scale PERCOLATION TEST ALL OUTLET 1E5FROM THE DISI1LEVEL F A R SHALL BE NEW FAST 05 TANK SET LEVEL FOR AT LEAST 2 FT. 7 2• 4caacREIE COVER p . 2-24" .ACCESS MANHOLES ' "... i ... LOW PROFILE TANK OUTLE Date of Percolation Test: JUNE 20, 2024 .� ��. KNOCKOUTS � '"•'� 't :2' _ Test Performed By: CARMEN E. SHAY, R.S., C.S.E. -!� I /A D EN ITE SYSTEM Results Witnessed By. BARRY LEWIS-YARMOUTH BOH _ y — - 15.5" OUTLET_ �I FAST 0.5EXCAVATOR: Shay Env. Svcs. SEPTIC TANK Percolation Rate: Less Than 2 MPI C 30" RCET ' THE ACCESS COVERS FOR THE SEPTIC TANK, DISTRIBUTION BOX AND LEACHING COMPONENT •. �-„-� . r. . , ,��: SHALL BE RAISED TO FINISHED GRADE. L7STEEL REINFORCED PRECAST CONCRETE PLAN VIEW H-10 3-as• REMOVAKE Cov1R.5 MIE 4• .YJ 3T:;.. e11.ET e" I.W. LOUTLET5' -7" --3' -7" ' MK depth 10 -a" " 5. _e. — END -SECTION TYPICAL (H-10 LOADING) 1500 GALLON _FAST SEPTIC TANK esign Calculations Test Hole No. 1 DEPTH SOILS ELEV. 0 7.80 Loamy Sand 10 YR 3/2 D"- 6" Ap 7.30 Loamy Sand 10 YR 5/6 6"- 30" E6 5.30 Med.-Coarse Sand 25 Y 7/4 30"-120" C, 2.20 15.5" 1.75. PLAN —SECTION CROSS SECTION Nor To SCALE 6 HOLE DISTRIBUTION BOX - H 10 PLOT PLAN OF PROPOSED SEPTIC SYSTEM UPGRADE AN ITA SCAR RY AT 16 GULLS COVE ROAD PARCEL ID: 17-157 WEST YARMOUTH MA OF PREPARED BY: Number of Bedrooms: 4 Equivalent to 440 Gal./Day (440 Gal./Day per Title V MINIMUM) Garbage Grinder: No �� M D /)if� %It T ( j,l�/1 E. Sjj1'1 Perc #i �� I•%'f� , 1 r �J n l Septic Tank - 2 x 440 Gal./Day = 880 USE EXIST. 1,000 GAL. Septic Tank. Depth to Perc: 30" to 48" ENVIRONMENTAL SERVICES SOIL ABSORPTION AREA: Using percolation rate of <2 min./inch Perc Rate= 2 MPI Assumed Groundwater Observed 0 62"-Weeping 11 01 PLUM HOLLOW ROAD SOIL ABSORPTION AREA: Using percolation rate of <2 min./inch Proposed Observed ESHWT - 62"or ELEV. 2.63 ? P AST FALMOUTH, MA 02536 Leaching Field Dimensions: 1 ® 20' Wide by 30' Long. ADJUSTED H2O Elev. = 0.80 Feet or ELEV: 3.43 Faf s; Bottom Area: 0.74 gal/sq. ft. x 600 sq. ft. =444 gallons OBS. GWI - 062"Weeping-(74" Standing)OR ELEV.-1.65 Sq ITIlk EL/FAX : 508-294-7498 SCALE: A SHEET 2 DRAWN BY: CES DATE: JULY 31, 2024 Sidewall Area: NOT USED Providing: = 444 gallons MIW-29 ZONE A - MAY 2024= 0.8' Adjustment ESHWT - 4.36' or ELEV.-3.43 Bottom of Test Hole = Elev.-(2.20) rPROJECT#16 GULLS COVE ILENAME: 16 GULLS COVE.DWG HEET 2 OF STATIC HEAD SALCULATION PUMP SPECIFICATION CALCULATIONS 7.32' - E7ev of D-Box In Provide Risers 2-18" DIAM. ACCESS MANHOLES 1,65' - £levotion of Bottom of Pump Chamber 2-20" RDAOVEABLE to bring INLET Pump Chamber cover MANHOLE COVERS WITHIN to grade and OUTLET cover to t7' 7.32 - 1.65' = 5.67' Static Head 6" OF FINISHED GRADE finished grade DYNAMIC HEAD RESTORE TO FINISHED GRADE ELEV. <`r `-- — : -- 3 •_. , Use Gould AAD*l 3886(WS036) Pump 920 Volt NOT TO SCALE Frfctlon Head For 3' SCH 40 PVC Pipe Phase ! j 9/2 HP 2' Solids Handling Ce r OUT CIiAIN 2" TO 3' ADAPTER 010 GPM - 0.10 Ft./100 R. O50 GPM - D.60 Ft./1t10 Ft. OR EQUIVALENT INLET INVERT �3' FORCE MAIN OUILET AiVtRT ELEV.- 8.65 INLET `� ��� OUTT 0100 GPM - 2.5 Ft./900 Ft. r: 0100 GPM - Ze f .- 8. 17 Ft. Total Dynamic Head 8.T7' O 100 CPM (r" EZE PMTECnON) 2' SWING CHECK WY.YE-P.Y.C. �'�/TWO THE ACCESS COVERS FOR THE SEPTIC TANK, DISTRIBUTION BOX AND LEACHING COMPONENT , . l { ;, ER �Fnggag BEWRNNI ROM:x GRADE SHALL BE RHAN AID TOS 1W�TIitN 6OW LOSS For F1Tl7NGS AL - 5.5PLAN 51" OF TANK STEEL REINFORCED PRECAST CONCRETE FbASHED GRAD•2s/3 ValorPTER Check V°ohro - 3.2" L VIEW2 INSTALL TUF-TITS GAS BAFFLES OR EWALS 2' Elbow - 0.5°3" EASow - 0.1ppi�pe eeqqulwAmt (x2=0.2) TOTAL AD1770AL4L PIPE EO(11YALENT=9.4 Feet' 3-24" REMOVABLE COVERS R PIMP CHAMBER ELEV.= 1.03 PUMP NOTES & SPECIFICATIONS ------- : ` := - { .: ,. 4' � .r.: , 12" aI 3/4' - 11/2' Stony 3" min. clearance INLET 8" min.T-12" min. Inlet to outlet G. min. -" 1J" INLET ' 1. PUMP SHALL BE INSTALLED IN S7R1CT COMPLIANCE WITH AHNUFACTURERS SPECIfICATILNJS. PUMP DETAIL Liq�ieMl ,o• min. OUTLET ILJI 2. ALARM SHALL CONSIST OF AUDIBLE SIGNAL &Not RED to SwM ,.• 5 -Y +� ` 5' -7" WARNING LIGHT TO BE INSTALLED IN BUILDING AND POWERED BY SEPAR47E CIRCUIT FROM E $ I 4V" min. -0 CIRCUITS TO PUMP. o v L-O depth J. DOSING SCHEDULE.• I , c 440 GALLONS/4 DOSES- 110 G4LLONSIDOSE I CROSS SECTION END —SECTION FLOAT LOCATION CALCULATIONS PUMP PERFORMANCE DATA TYPICAL 1000 GALLON MONOLITHIC SEPTIC TANK 110 Gallons / Z 48 CAL./Cu It = 14.70 Cu Ft Area of Bottom of Chamber = 5 x 8' = 40 Sq. Ft. Height of Water for One Dbae (H) = 14.79 Cu. Ft / 40 Sq. Ft. H = .37 Ft. = 4.5 INCHES Pump On = 10.0" 1 L14YS FLOW ADD/T OW CAPACITY.- Pump Off = 14.5" 48"-18" = 30` or 2.5' o 2.5' x 5' x 8' = 100 cu feet ° Alarm 19" 100 cu fact x 7.48 gol/cu ft 748 Gallons I ADD/770N41 CAPACITY NEEDED is 1 days flow or 330 gallons 0 BUOANC Y CAL CULA TIONS v T t] v Weight of Septic Tank: 11, 480 lbs. 10 Weight of Soil Above Tank 5,555 lbs. Total Weight Down: 17, 035 lbs. Weight of Water Displaced: 7,295 lbs of H2O USED AS A PUMP CHAMBER H-10 & WATER PROOFED PLOT PLAN OF PROPOSED SEPTIC SYSTEM UPGRADE PREPARED FOR ANITA SCARRY AT 16 GULLS COVE ROAD PARCEL ID: 17-157 WEST YARMOUTH MA * No Ballast Required For Septic Tank .00F PREPARED BY: Weight of Pump Chamber: 8,250 lbs. �'" �CARNEW E. SffA Y Weight of Soil Above Tank 4,444 lbs. v ENVIRONMENTAL SERVICES Total Weight Down: 12,694 lbs. 201 PLUM HOLLOW ROAD Weight of Water Displaced: 5866 lbs of H2O EAST FALMOUTH, MA 02536 * No Ballast Required For Pump Chamber gtRr*TEL/FAX : 508-294-7498 SEAL A SHEET 3 1 DRAWN BY: CES DATE: JULY 31, 2024 PROJECT#16 GULLS COVE ILENAME: 16 GULLS COVE.DWG HEET 2 OF 40 40 20 0 0 20 40 60 80 100 120 14