HomeMy WebLinkAbout2024-10-21 Station Ave. Sunoco Hazmat Inspection ReportTown of Yarmouth, MA
Inspection Report
Inspection: Inspection
Inspector: Carl Lawson
Inspection Date: Oct 21, 2024
Record: Toxic or Hazardous Materials Internal Inspection #THMI-24-23
Location: 433 STATION AVE, SOUTH YARMOUTH, MA 02664
Applicant:
Hazardous Materials
Overall Result: Pass
Overall Remarks:
HAZARDOUS WASTE TYPES - HAZARDOUS WASTE HAULERS
OIL-Safety Kleen /Cyn Oil
ANTIFREEZE-Safey Kleen/Cyn Oil
OIL FILTERS-crushed-drained for 24+hours and then disposed in the trash
AUTOMOTIVE BATTERIES-taken back by the suppliers
TIRES- removed by Cape & Islands Tire or Town Fair Tire
RAGS- disposable rags are put in trash and are not solvent soaked
PARTS WASH FLUID - no parts washer on-site-if a small amount of solvent is
applied to a part it is reclaimed and added to the waste oil tank
UNDERGROUND STORAGE TANK (UST) SUMP COLLAR WASTE WATER-none
- all USTS have been removed
POWER STEERING AND BRAKE FLUID FLUSHES - minor fluids like these go to
waste oil tank
SAFETY DATA SHEETS (SDS) -all are on file on PCs, backed up on flash drive
and available to staff
Checklist:
Aquifer Protection District
Result: Pass
Remarks:
Yes
Storage is in product tight container
Result: Pass
Containers are stored to allow visual inspection for damage / leakage
Result: Pass
Storage is in secondary containment (dike, berm)
Result: Pass
Remarks:
Two 55-gallon drums are on a poly spill control pallet with 130 gallons of sump
capacity. One of the two drums will be used up and not replaced so only one
will be stored in the future.
Adequate bermed area
Result: Pass
Remarks:
Yes, 275-gallon waste oil tank is inside a mortared concrete block containment
area.
Aboveground Storage Tanks
Result: Skip
Remarks:
None-building uses gas heat.
Underground Storage Tanks
Result: Skip
Remarks:
All have been removed and a close-out report by a Massachusetts Licensed
Site Professional (LSP) was submitted to the Health Dept. and stated soil
analysis found no indication of petroleum impact.
Storage is in display area
Result: Pass
Remarks:
Minor display of fluids for retail sale is inside customer area.
Storage areas are clean and free of signs of spillage
Result: Pass
Hazardous Materials / Hazardous Wastes are properly labeled
Result: Pass
Spill cleanup materials (sorbent pads, Speedy Dry) on site
Result: Pass
Remarks:
Yes-a large pail of pelletized clay absorbent is available
Floor drains present
Result: Skip
Remarks:
No
Floor drains permanently sealed
Result: Skip
Remarks:
Yes
Holding Tank
Result: Skip
Remarks:
None