HomeMy WebLinkAbout107 Route 6 A Main House Inspection ReportTown of Yarmouth, MA
Inspection Report
Inspection: Inspection
Inspector: Brian Coughlin
Inspection Date: Feb 14, 2025
Record: Rental Registration #BHR-25-9
Location: 107 ROUTE 6A, YARMOUTH PORT, MA 02675
Applicant: Tim Chiang
Rental Inspection
Overall Result: Pass
Overall Remarks:
Main House- Owner provided code to enter home for
inspection. Home is in very good condition with a few minor
repairs needed.
Checklist:
1.
Number of Bedrooms/Measurements
Result: Pass
Remarks:
1) 13'6" x 13'7" 2) 11'5" x 11'11" 3) 8'1" x 13'1" 4) 10'3" x 20'11" 5)
9'9" x 11' 6) 10'1" x 23'8"
2.
Maximum Occupancy: Based on septic system capacity, number
of bedrooms and bedroom square footage
Result: Pass
Remarks:
12
3.
Basement
Result: Pass
Remarks:
Unfinished
4.
Electrical Panel
Result: Fail
Remarks:
Panel unlabeled - Label circuit breakers
5.
Copy of Tenant's Legal Rights have been issued to tenant.
Result: Pass
Remarks:
Left on counter
105CMR 410.00 0Minimum Standards of Fitness
for Human Habitation
(State Sanitary Code: Chapter II)
Result: Pass
410.100 Kitchen Facilities
*
Result: Pass
410.110 Bathroom Facilities : Sinks, Toilets, Tubs
& Showers
*
Result: Pass
410.120 Approved Toilets
*
Result: Pass
410.130 Water supply
Potable Water/Sanitary Drainage
Result: Pass
410.140 Plumbing Connections
*
Result: Pass
410.150 Hot Water
110-130 °F for faucets & 110-120 °F for bathtubs a & showers
Result: Pass
410.160 Heating Systems
*
Result: Pass
410.170 Venting
*
Result: Pass
410.180 Temperature Requirements
Owner shall proved heat in every habitable room & every room
containing a toilet, shower or bathtub from September 15th
through May 31st. 64° from 11:01 pm to 6:59 am 68° from 7 am
to 11:00 pm
Result: Pass
410.200 Provision and Metering of Electrical or
Gas
*
Result: Pass
410.210 Provision of Oil
*
Result: Not Observed
410.220 Natural and Mechanical Ventilation
*
Result: Pass
410.230 Owner's Laundering Responsibilities
If owner provides bed linens, towels, pillows or mattress
Result: Pass
410.235 Owner's Installation, Maintenance and
Repair Responsibilities
*
Result: Fail
Remarks:
- Missing covers on electrical boxes in basement - Replace
outlet / cover plate with exterior outlet and cover - Exposed
wiring - Re wire outlet concealing wire
410.240 Occupant's Installation and
Maintenance Responsibilities
*
Result: Pass
410.250 Asbestos-containing Material
*
Result: Pass
Remarks:
None observed
410.260 Means of Egress
*
Result: Pass
410.270 Locks
*
Result: Pass
410.300 Electrical Supply & Illumination
*
Result: Pass
410.310 Auxiliary Emergency Lighting Systems
& Exit Signs
For properties with 10 or more units
Result: Not Observed
410.320 Electrical Service
Temporary Wiring, Amperage
Result: Pass
410.330 Smoke Detector and Carbon Monoxide
Alarms
*
Result: Pass
Remarks:
In correct locations and working
410.400 Owner/Manager Contact Information
and Notice of Occupants' Legal Rights and
Responsibilities
Contact information and postings inside and outside of home
Result: Pass
410.410 Building Identification
*
Result: Pass
410.420
Habitability Requirements
Result: Pass
410.430 Natural Light and Obstructions
*
Result: Pass
410.470 Lead-based Paint Hazards in Residence
*
Result: Pass
Remarks:
None observed
410.500 Owner Responsibility to Maintain
Building & Structural Elements
*
Result: Pass
410.510 Occupant 's Responsibility Regarding
Building and Structural Elements
*
Result: Pass
410.520 Protective Railings and Walls
*
Result: Pass
410.530 Weather-tight elements
*
Result: Pass
410.540 Installation of Screens
*
Result: Pass
410.550 Elimination of Pests
Owners & Occupants are responsible for the control &
elimination of pests
Result: Fail
Remarks:
Evidence of rodents entering side door entrance to basement.
Install door threshold or new door to stop intrusion of pests.
410.560 Refuse
*
Result: Pass
410.570 Maintenance of Areas in a Sanitary and
Safe Condition
*
Result: Pass
410.620 Conduct of Inspections
The need for an additional inspection by a specialized inspector
pursuant to 105 CMR 410.620(A) and the reason that such
inspection is necessary
Result: Pass
410.630 Conditions Deemed to Endanger or
Materially Impair Health and Safety
One or more of the violations cited on this report may materially
impair the health or safety and/or well-being of any person(s)
occupying the premises
Result: Pass
780 CMR 111.5.1 Posting of Use & Occupancy
STR Only
Result: Not Observed
780 CMR 111.5.2 Required Egress posting
STR Only
Result: Not Observed
780 CMR Means of Egress
STR Only
Result: Not Observed
780 CMR R314 & R315 Smoke/CO/Heat
STR Only
Result: Not Observed
R314 & R315 Smoke/CO/Heat Detectors
STR Only
Result: Not Observed
This inspection report is signed and certified
under the pains and penalties of perjury.
Inspector's signature, date and time
Result: Pass
Remarks:
Brian Coughlin 2/14/2025 2:00 pm