HomeMy WebLinkAboutBHDC-19-3256 (3)N SEPTIC SYSTEM DESIGN 0 FLOW ESTIMATE: 2 BEDROOMS AT 110 GAL / DAY = 220 GAL / DAY GN SEPTIC TANK: 220 GAL / DAY x 2 DAYS = 440 GAL WAMPANOAG RD USE 1500 GALLON SEPTIC TANK LOCATION MAP PARCEL56 (4,871 SF) ASSESSORS MAP: 33 PARCEL: 56 PLAN BOOK: 56, PAGE: 85 LEACHING AREA: USE 18 INFILTRATOR QUICK 4 PLUS STANDARD CHAMBERS AS SHOWN (26' x 9' x 8" EFFECTIVE DEPTH) SIDE AREA: NA (0.74) = NA GAL/DAY BOTTOM AREA: 4' x 18 UNITS x 4.7 = 338 SF (0.74) = 250 GAL/DAY CAPACITY = 250 GAL/DAY FINISHED GRADE 2% 100.5 ELEV 6" x 6"(30 YEAR) PRESSURE TREATED RAILROAD TIES --STAGGER JOINTS AND CONNECT WITH 12" SPIKES Po 0�01Io 0 a o 0 0 0 0 (if1.7 PROPOSED LEACHING CHAMBERS ELEV 40 MIL POLY LINER ON INSIDE OF WALL TOTAL LENGTH OF LINER = 101' x (2.5') TOP OF LINER = 99.7 BOTTOM ELEVATION = 97.2 RETAINING WALL DETAIL 97.6 X KEY: EXISTING CONTOUR: PROPOSED CONTOUR: EXISTING SPOT ELEVA7 ,.)N: 25.5 PROPOSED SPOT ELEV. •.ION: 25.5 TEST HOLE: Y UTILITY POLE: -O- FENCE LINE: HYDRANT: RETAINING WALL: 100 99 98 0'Ka 24" oak // oC 8' ,oc lo$ I I I 1 I 98 97.9 STEP R.R. TIES IN 1/4" 9M GRADE ELEV. SEPTIC SYSTEM SECTION FI ' U ELEV, m (EXISTING) N o PROPOSED = 97.0 3 m LLEACH AREA DETAIL i��i���■�i 100.02 TOP OF FOUNDATION 1/8" perft BUOYANCY CALCULATION: 1500 GALLON SEPTIC TANK 10.5' x 5.67' x (94.7 - 92.4) x 62.4 LB/CF = 8,544 LB WEIGHT OF TANK = 11 480 LB DM ELEV. WEIGHT OF SOIL COVER: 10.5' x 5.67' x V x 100 LB/CF = 5953 LB BUOYANCY CALCULATION: 1000 GALLON PUMP CHAMBER 8.5'x 4.83'x (94.7 - 92.0) x 62A LB/CF = 6,917 LB 2' x 1/2" REBAR @ 4' ON CENTER WEIGHT OF TANK = 8,240 LB WEIGHT OF SOIL COVER: 8.5' x 4.83' x V x 100 LB/CF = 3,765 LB BENCHMARK AT HYDRANT TAG BOLT ELEVATION = 101.51 102N 101 102 101 N 1213 Qs,J 9 03 coy EXISpRp0N1 DEft 1N pp p2 pD top tad' ace) �cra*l Sp 2 , � ' c S �29�0 221 � 99 X 99.4 -X 99.6 12" oak PC ST 3.0 W Gravel Drive ELEV. I 92.4 1500 GAL ELEV. SEPTIC TANK ((i" OF STONE UNDER OR MMECHANICALLY COMPACTED) TEE SIZES: INLET: 6" UP, 13" DOWN OUTLET: 6" UP, 14" DOWN BED ROOM BATH SUN KITCHEN ROOM 1/8" perft ELEV. 2" PRESSURE LINE TO EXIT THROUGH RISER OR TANK. A QUICK DISCONNECT IS TO BE PROVIDED FOR FUTURE ACCESS TO PUMP. PUMP CHAMBER COVER TO BE AT GRADE. ALL OTHER COVERS AND INSPECTION PORT TO BE WITHIN 6" OF GRADE. TEE AT __\ INLET 1/8" pe 99.58 99.41 ELEV. ELEV. D-BOX (6" OF STONE UNDER) /92.0 1000 GAL GAS ELEV. PUMP CHAMBER BAFFLE WITH MYERS SRM-4 PUMP. PUMP ALARM ZABEL PACKAGE TO BE INSTALLED IN DWELLING FILTER POWERED BY A CIRCUIT SEPARATE FROM THE PUMP POWER. (DISTANCE BETWEEN ON/OFF SWITCH TO BE 3") DISTANCE BETWEEN ON SWITCH ND ALARM TO BE 12") 1/4" DRAIN HOLE -CHECK VALVE i BED TEST HOLE LOGS ROOM ENGINEER: THOMAS McLELLAN, P.E. WITNESS: PHIL RENAUD DATE: 10-25-18 PERCOLATION RATE: < 2 MIN/IN LIVING ROOM USGS GROUND WATER ADJUSTMENT: WELL: MIW-29, ZONE: A, ADJ.: 2.3' / 2 = 1.2' ADJUSTED GROUND WATER ELEV.= 94.7 EXISTING FLOOR PLAN I r�> a Q� r_ *PN 3 100 e,(n m0 0 hydrant 99.5 Permit valid for REPAIR OF' SEPTIC SYSTEM> ONLY, due to State and Local septic variances. ® ® Board of IIIeaith review and approval is required for EXISTING v future add itions/renm ations/afterations to DRAINA12 SYSTEM YSTEM swage facilities and/or structuaes/dwelling. rr. SYSTEM Yarmouth Health 1>.epartmendt 99.6 o APPROVt t oCTIC , cCq 117 � 1jL/4-L atlle Date NOVgE �� 40 MIL POLY LINER ALSO ON INSIDE OF WALL 101' x 2.5' DEEP TOP OF LINER = 99.7 BOTTOM ELEVATION = 97.2 i JUN u b 2019 HEALTH DEPT. REQUIRED VARIANCES FROM TITLE FIVE: 1. SECTION 15.212: LEACH AREA TO BE LESS THAN 5' ABOVE GROUND WATER (VARIANCE OF 1.0'). 2. SECTION 15.211 (1): LEACH AREA TO BE LESS THAN 20' FROM CRAWL SPACE (VARIANCE OF 11'). 3. SECTION 15.211 (1): LEACH AREA TO BE LESS THAN 10' FROM LOT LINE (VARIANCES OF V & 2'). 4. SECTION 15.211 (1): PUMP CHAMBER TO BE Lf 3S THAN 10' FROM LOT LINE (VARIANCE OF 5'). 5. SECTION 15.255 (5): SOIL REMOVAL 10 BE LESS THAN 5' (VARIANCE OF 2'). T MAX. COVER (1' MIN) NOTE: 8" EFFECTIVE DEPTH INLET IS NOT THE CENTER LINE INLET. INSPECTION PORT ELEV= 99.7 29.37/ II11-1NNNNH1-1N1°I1-1NNNHN1II 98.7 ELEV. ELEV. E 26' x 9' USE 18 INFILTRATOR QUICK 4 PLUS 4 STANDARD CHAMBERS AS SHOWN (26' x 9' x 8" EFFECTIVE DEPTH) ADJUSTED GROUND WATER ELEVATION = 94.7 TH-1 98.5 FILL FILL ELEV. 18" O/A HORIZON LOAMY SAND 30" 10YR 3/1 6.0 B HORIZON LOAMY SAND 42" 10YR 5/8 0 C HORIZON MEDIUM SAND 2.5Y 7/4 60" OBSERVED 93.5 108" 1 GROUNDWATER 1 89.5 NOTES: 1. VERTICAL DATUM: ASSUMED 2. MUNICAPAL WATER IS AVAILABLE. 3. SCHEDULE 40 - 4" PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. 4. ALL PRECAST UNITS SUBJECT TO TRAFFIC LOADS TO CONFORM WITH AASHTO H-20 SPECIFICATIONS. 5. PIPE PITCH = 1/8" PER FOOT (UNLESS NOTED OTHERWISE). 6. FIRST 2' OF PIPE OUT OF D-BOX TO BE SET LEVEL. 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOSAL. 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS. ENVIRONMENTAL CODE (TITLE FIVE) AND LOCAL HEALTH REGULATIONS. 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO EXCEED 31. 11. FIELD SURVEY PROVIDED BY TERRY A. WARNER, P.L.S., HARWICH, MA. 12. THIS PLAN REQUIRES THE REVIEW AND APPROVAL OF ONE OR MORE TOWN DEPARTMENTS AND IS SUBJECT TO CHANGE UNTIL SUCH TIME. 13. EXISTING CESS POOL(S) IS TO BE LOCATED AT TIME OF CONSTRUCTION. j IT IS TO BE PUMPED AND REMOVED. Ir . D-BOX TO BE WATER TESTED TO ENSURE LEVELNESS AND EQUAL FLOW. 5. AN ELECTRIC PERMIT FOR THE PUMP SYSTEM IS REQUIRED PRIOR TO CONSTRUCTION. 16. SEPTIC TANK AND PUMP CHAMBER ARE TO BE WATER PROOFED BY MANUFACTURER WITH IPANEX CONCRETE ADDITIVE OR CONSEAL 55. A 6" EZ WRAP IS ALSO REQUIRED FOR BOTH TANKS. 17. ALL UNSUITABLE SOIL, (O/A HORIZON, APPROX. 30" DEEP) WITHIN T OF PROPOSED LEACH AREA IS TO BE REMOVED AND REPLACED WITH CLEAN MEDIUM SAND. THOWSJ. WEILAN : CIVU No.36471 Q t7D' SITE PLAN LOCATION: 19 BLISCOTT AVE., S. YARMOUTH, MA PREPARED FOR: EUGENE KOVAL DATE: 12-12-18 SCALE: I" = 20' BASS RIVER ENGINEERING THOMAS J. McLEL N, P.E. P.O. BOX 1163, EAST DENNIS, MA 02641 508-364-9048