Loading...
HomeMy WebLinkAbout22 Windjammer LnELEV. TOP PROP Q5.M-T4AjN < FOUNDATION INSTALL RISERS W/IN 6" OF FINISH GR4X (Existing) = 102.29-,,,- CELLAR FLOOR i GS=2X a (MIN.) .......... PROVIDE COUPLING INV: 100.54 INV.=1 OOA 4 EL.101) TEE'S ARE M BE 4" SCH 40 PVC GAS BAFFLE T_PUMP S:Lif>AaE:�: iNSTAU. R SERS W1I4 6' 07, PNISI- GRADE FL. 100 El.. i 001 0- OO 4" SCH 40_pVC 0 S= 1% (MIN.) 10• INV.== 98.35 / W P12" INV.=98.25--/ .l-eox INSTALL RISLRS 'N/ IN 6" OF FINISH GRADE. F.G. EL: 100 l: :PE7) SAN{1ARY TEE.. pqc FORCE "_iZINV. =9 INV.= 99.22 D_=K,X TEE SHALL NOT EXTEND BELOW FLOW LINE DB-6 T 1,000 GALLON SEPTIC TANK (H-• 10 LOAD.? INV-=98.0 GAS BAFFLE TO BE INSTSALLED ON 1000 GALLON PUMP CHAMBER(H-10) OUTLET TEE AS MANUFACTURED BY TUF-TITE, ZABEL, OR EQUAL. NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING 3) INSTALL INLET &. OUTLET TEES AS REQUIRED PIPE INVERTS PRIOR TO CONSTRUCTION. 4) REPLACE EXISTING 1,000 GALLON SEPTIC 2) SEPTIC TANK, PUMP CHAMBER AND D-BOX SHALL BE TANK WITH 1500 GALLON SEPTIC TANK SET LEVEL AND TRUE TO GRADE ON A MECHANICALLY IF FAILED, DAMAGED, OR UNDERSIZED, COMPACTED SIX INCH CRUSHED STONE BASE, AS SPECIFIED 5) INSTALL SANITARY TEE IN D-BOX IN 310 CMR 15.221(2). SEPTIC; SYSTEM PROFILE N.T.S. INSTALL 1' PVC CONDUIT TO HOUSE FOR HARING WITH WATERTIGHT JOINTS. WARE HIGH WATER .ALARM - PROVIDE WATERTIGHT CONCRETE RISER FLOAT TO GP 2000 HIGH WATER ALARM PANAL ON W►TH SECURED COVER TO GRADE CIRCUIT SEPARATE FROM CIRCUIT TO THE PUMP. -Z NEMA 4 JUNCTION BOX CORROSION RESISTANT HOISTING CABLE 7x19 STAINLESS STEEL. \ / & LIQUID -TIGHT CABLE CONNECTORS SUPPORTED BY 1-1/4" PVC CONDUIT. JOINTS TO BE MADE- 1/8- DIAMETER. / 1,760 LB. STRENGTH. WATERTIGHT - 2"BALL VANE w/ UNIONS SCH. 80 PVC PC INV.(IN)=98.25 GEORGE FISHER CO. MODEL NO. 560 OR EQUAL r 2"SCH. 40 DISCHARGE TO D-BOX ALARM ON EL: 96.66 - "�---2"SCH. 40 TEE w/ CLEAN -OUT CAP PUMP ON EL: 95.33 PROVIDE 1/4" WEEP HOLE IN DISCHARGE PUMP OFF EL: 95.0 32" 6 PIPE FOR SELF -DRAINING FORCE MAIN �•�� BOTTOM OF - 16" --- PUMP CHAMBER (12 -2" BALL CHECK VALVE SCH. 80 PVC - 100 P.S.I. FLO*AAT1C MODEL No. 208S P OVIDE 2•- 1MDE AN( FLQAy --� 2" SCH. 40 PVC OISCHARGE PIPE FLOAT NOA: PUMP ON/OFF (BARNES 073618 OR EQUAL) FLOAT NO.2: ALARM ACTIVATION (,BARNES 073612 OR EQUAL) BARNES SEV412 PUMP .5 H.P. i15 V 2" DISCHARGE PASSING 2` SOLIDS OR FCtUAI_ PUMP CHAMBER, PUMP & ACCESSORIES AVAILABLE AS A UNIT THROLIGN WIGGE.N PRECAST CORP., BOURNE MA. (800) 564-6774 PUMP & ACCESSORIES AVAILABLE THROUGH WLLIAMSON E<ECTRIC (781) 444-6WO PUMP DETAIL-.. N.T.S. BUOYANCY CAL_CULATICNS No Buoyancy Calculations RequrieJ I; DOSING & STORAGE REQUIREMENTS DAILY FLOW: 330 GPD DOSING REQUIRED: 4 CYCLES/DAY (SAND) 330 •-- 4 == d2.5 GALLLONS/CYCLE DISTANCE REQUIRED BETWEEN PUMP ON AND PUMP OFF FLOATS: 8I.5 GAh/CYC:.E- 250 GAL/FT = 0.33 FT/CYCLE (4"') '310RAGE RECUIRED AB(rJL WORKING LEVEL: 330 GALLONS STORAGE PROVIDED: Im"(IW) EL:98 25 - PUMP ON EI-:95.33 =2.92' 5T'Qj3AG(. 2..56' X w50 GAL%F`" = 730 GALLONS FINISH GRADE=100.25 MAINTAIN 2% MIN SLOPE OVER LEACHING AREA ;1 MAX. COVER OVER S.A.S. == 36," 1. =1 '(MAX) 4" SCH 40_P_VC ® S= 19; (MIN.) INVERT INV.ELEV.=98.92 SPLASH PAD TO CONSIST OF UNDERLAYMENT OF FILTER FABR EXTENDING 16" IN FROM START OF ROW ----INSPECTION FORT TO BE. PLACED ON ENO UNIT I 3 ROWS OF 3-CULTEC G-4 UNITS x 8' ._L UNIT=24' -- - - - -- -- -- --_-_ SOIL ABSORPTION SYSTEMS R0.FILE) N.T.S. • i::J�i e4:� r.�r� .;.Fi.r� : of :�oi52i� !r : rI':�ri : ;•r. �.;..,,� _,. -- ESTABLISH VEGETATIVE COVER BACKFILL WITH CLEAN SAND (NATIVE OR PERC SAND) -BREAKOUT Al", 1 ", ' ELEV.=98.67 48" (TYPICAL) ---i 6" E-- 5' MIN. ABOVE BOTTOM OP __ _ - _.--------.--.__.------__-.. T.P. EXCAVATION OR G.W. EFFECTIVE WIDTH==13.0' ADJ. GW EL: 93.67 -_ USE 3 ROWS OF 3--CULTEC C•-4 FIELD DRAIN UNITS WITH 6' SEPARATION BETWEEN EACH ROW & NO STONE SOIL ABSORPTION SYSTEM SECTION EXISTING SUITABLE MATERIAL //�� DESIGN \ _ CRITERIA `"'t rtx ' -it , O, 1140 1 D C) I L I__ �J G S NUMBER OF BEDROOMS 3 BEDROOM % -- -- --' - -- -- SOIL TEXTURAL CLASS: CLASS I �Ni TAR\P�� DK! E: MAY 30, 2007 SO!;_ EVALUATOR: DARREN MEYER, R.S., CSE WITNESS: AMY VONHONE, YARM. BOH PET-:; RATE <2 MIN/IN. ("C" HORIZON) .Elev. TH- 1 Depth 99.0 --- - 0" A LOAMY SAND IOYR 7/1 _ l 98.33 B ---- ---- 8" LOAMY SAND IOYR 6/6 95.67 C----------- --- 40" MEDIUM SAND 2.SY 6/6 90.67 _..___----.__-.-- 100" CROUNDX'ATER 06SERVED AT 76" EL. 92.67 IN:)EX WELL: A1W-230 ZONE C LEVEL: 21.7 ADJUSTMENT: 1.2. ft. LIST BOARD OF HEALTH ALLOWED ADJ: 1.0 ft. ADJUSTED HIGH GROLIULYWAIER AT EL. 93.67 DESIGN PERCOLATION RAZE: <2 MIN/IN DAILY FLOW: 1 10 G.P.D./BR C l b DESIGN FLOW: 330 G.P.D. (MIN REQ'D) GARBAGE GRINDER: NO PROPOSED SEPTIC TANK: 1000 GALLON (existing) PROPOSED PUMP CHAMBER: 1000 GALLON LEACHING AREA REQUIRED: (330) = 4A5.9 S.F. .74 USE 3-_ROWS _OF' 3 , CULTEC C-4_ UNITS WITH l [Q STONE FOR AN S.A.S. HAVING THE _DIMENSIONS 13,0'x .24.0'.. BOTTOM AREA: (GENERAL USE APPROVAL. FOR 67 SF/LF OF C-4 UNIT) 3 UNITS x 8.0'/UNIT = 24.0 FT 3 ROWS x 24.0' x 6.7 SF/LF = 482.4 SF DESIGN FLOW PROVIDED: 0.74(482.4 S.F.) = 357.0 G.P.D. PROPOSED _SEPT IC SYSTEM UPGRADE PLAN 22 WINDJAMMER ROAD, SOUTH - YARMOUTH, MA __________-_----------Prepare:i for: Todd Krinsky Engine-ei in+g by: --- -- Surveying by: - -� - - - SCALE- DRAWN _- JOB NO. DARRENM. ME}£R, R.S. Waiver Sm-meying N.T.S. DMM P0BOA 981 22 Long R<>od EAS3'SANDtW_H,?WA02531 Harwich, MA 02645 DATE CHECKED SHEET NO. WO362:2922 (;-08) 432--8:i09 06/10/07 DMM 2 of 2