HomeMy WebLinkAbout60 BroadwaySCHEDULE OF ELEVATIONS 44 /j e a� 1 FIRST FLOOR = 18.8 tt K .6 �9 u 2 TOP OF FOUNDATION = EXISTING x 3 PIPE INV. AT FOUNDATION = 13.17, EXISTING x a ,r 4 INV. OF PIPE AT SEPTIC TANK INLET = 12.83, EXISTING' � grey N Wpp'i° f I 5 INV. OF PIPE AT SEPTIC TANK OUTLET = 12.58 + SrrN-, ss i° w N to 6 INV. OF PIPE AT D-BOX INLET = 12.50 W iA x 7 INV. OF PIPE AT D-BOX OUTLET = 12.33 so x 8 INV. OF PIPE AT LEACHING FIELD INLET = 12.08 4 u f s � w 9 BOTTOM OF LEACHING FIELD = 10.08 y�c 10 TOP OF STONE 12.92 a a ss obi 4 Is 11 FINISHED GRADE OVER LEACHING FACILITY = 14.0 - 17.0 �J4 .. 8, 12 FINISHED GRADE OVER D-BOX = 16.5 4aJ� LOCUS ? LOCUS f: 0 �� 13 FINISHED GRADE OVER SEPTIC TANK = 16.6 - 17.2 fs sf, "Pr 14 FINISHED GRADE AT FOUNDATION = 17.3 ¢cam a Q � usrs , 15 BOTTOM OF SEPTIC TANK = 7.08 16 CRAWL SPACE = EXISTING LOCUS MAP NOT TO SCALE N _ O co OD Q Z O _ -. o r, _ O _ O DWELLING 16 Tt. 0 2 114 1 SEWAGE SYSTEM PROFILE & DETAILS NOT TO SCALE NOTES: SEPTIC SYSTEM NOTES %vt OF 1. FURNISH RISERS TO SET COVERS WITHIN 6 INCHES OF FINISH GRADE. 2. H-20 SEPTIC TANK, CHAMBERS AND DISTRIBUTION BOX (D-BOX), AND SCHEDULE 40 PVC PIPE THROUGHOUT. 1. ALL CONSTRUCTION AND MATERIALS SHALL CONFORM TO THE STATE 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING A TRENCH PERMIT FROM THE LOCAL MUNICIPALITY IN ENVIRONMENTAL CODE, TITLE 5 (310 CMR 15.00), AND THE LOCAL BOARD OF WHICH THE WORK IS BEING PERFORMED. HEALTH 13 RISER AND COVER TO BE SET T 12 WITHIN 6" OF FINISHED GRADE & 4 SERVE AS INSPECTION PORT 5 S=2% MINIMUM FILTER FABRIC H-20 D-BOX BACK FILL WITH WITH FIRST 2' SHALL 9" MIN. 36" MAX. EVELERS BE SET LEVEL S=0.02 MIN. L=13' ��., CLEAN MATERIAL S=0.01 MIN. L=8' S=0.01 MIN. L=VARIES n r; j SCH. 40 PVC TEES 00 ---------- - 15 ROPOSED 2-COMPARTMENT ' EXISTING BUILDING SEWER NOTES 1 - BUILDING SEWER PIPE INVERT ELEVATION TO BE CONFIRMED PRIOR TO CONSTRUCTION. 2 - CONTRACTOR SHALL INTERCEPT EXISTING BUILDING SEWER WITH NEW 2,500 GALLON 2-COMPARTMENT SEPTIC TANK AND INSTALL 4" PVC "T"s IN SEPTIC TANK 2,500 GALLON, H-20 LOADING WAT GPTE MAINE AVENUE -- �-- -- - - - (40' WIDE - PUBLIC) GAS GATE 1 GAS SERVICE AS MARKED O%--- G G G G G G G G G G GUY POLE GCB DISC' O O L7 0 c� UP OH OHW OUND PAVED STOCKADEFENCE \ 0 PAFRKING O \ \ IN,O 0 \ =WOOD ALCONY _ - CONCRETE = T PATIO 2 V I I Q co `� I I I LU �m I o 0 d I o `� � O o` Z �`m I APPROXIMATE LO ATION I OF WATER SERVICr PER w O o \ TOWN RECORDS W 'L W N w I 2,500 GALLON I) 2-COMPARTMENT WOOD BALCONY - I L-.,.... GAS METER I I I I I I I I I I I �k O I I I CONDOMINIUM FIN. FLf EL. = 18.8 I I I �SIAILED I I I SEPTIC �YSTEM I CgNC LANDING (TVP)� LL >OD BALC NY in `� C 6 6" MIN. CRUSHED STONE BASE 5. 7 O 2. THERE SHALL BE NO CHANGES MADE IN THIS PLAN WITHOUT THE WRITTEN PERMISSION OF THE ENGINEER AND LOCAL BOARD OF HEALTH. PROPOSED VENT, FINAL LOCATION 11 TO BE DETERMINED IN THE FIELD 3. ALL ERRORS, OMISSIONS, AND CHANGE OF CONDITIONS AT THE SITE SHALL BE 10 BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO PERFORMING THE RELATED WORK. 4. ALL DISTURBED AREAS ARE TO BE LOAAED, SEEDED AND MAINTAINED TO z PREVENT EROSION. 2 5. FOR PROPER PERFORMANCE, SEPTIC TANK SHOULD BE INSPECTED AT LEAST ONCE A YEAR AND WHEN THE TOTAL DEPTH OF SCUM AND SOLIDS EXCEEDS 15' MIN. BREAKOUT GRADE 1/3 THE LIQUID DEPTH OF THE TANK, THE TANK SHOULD BE PUMPED. 6. THIS SYSTEM HAS BEEN DESIGNED FROM DATA REVIEWED AND ACKNOWLEDGED BY THE MASS. D.E.P. AND THE LOCAL BOARD OF HEALTH, AND CONFORMS WITH THE REQUIREMENTS OF THE STATE ENVIRONMENTAL WJ Q= /,\ CODE, TITLE 5. NO GUARANTEE OF PERFORMANCE IS EXPRESSED OR IMPLIED. �o 0 0 0o v 0! C7 v U � o 92 O 0 0 (� f� 0 o I� lc M > W 7. TEST HOLE INFORMATION SHOWN HEREON IS LIMITED TO SOIL CONDITIONS N w w O ET [� O O O O = FOUND AT THAT PARTICULAR TEST HOLE LOCATIONS AND IS NOT CONSIDERED u _ PRECAST 500-GALLON CHAMBERS AN IMPLIED OR EXPRESSED WARRANTY OF SOIL CONDITIONS BEYOND LIMITS OF SUCH TEST HOLES. 4' OF NATURALLY OCCURRING 8. ALL ORGANIC AND UNSUITABLE MATERIAL MUST BE REMOVED FROM THE PERVIOUS MATERIAL � AREA DIRECTLY UNDER AND 5 FEET BEYOND THE PROPOSED LEACHING ui CONTRACTOR SHALL CONTACT ENGINEER TO ASSESS EXISTING FACILITY. THIS AREA MUST BE BACKFILLED TO THE ELEVATIONS INDICATED ON SOIL MATERIAL PRIOR TO INSTALLATION OF LEACHING SYSTEM. THESE PLANS WITH SELECT ON -SITE OR IMPORTED SOIL MATERIAL, UNSUITABLE MATERIAL ENCOUNTERED DURING INSTALLATION CONSISTING OF CLEAN GRANULAR SAND OR OTHER GRANULAR MATERIAL, ADJUSTED GROUNDWATER SHALL BE REMOVED -REFER TO SEPTIC SYSTEM NOTE 8 FREE FROM ORGANIC MATTER AND OTHER DELETERIOUS SUBSTANCES. EL.= 4.8 (NAVD88) MIXTURES AND LAYERS SHALL NOT BE USED. THE FILL MATERIAL SHALL CONFORM TO THE STATE ENVIRONMENTAL CODE, TITLE 5 - 310 CMR SECTION USE (5) 500-GALLON CHAMBERS WITH DOUBLE WASHED CRUSHED STONE 15.255 (3) AND SHALL HAVE PERCOLATION RATE OF BETWEEN TWO AND FIVE 42" AT ENDS AND SIDES, AND 36" BETWEEN EACH CHAMBER MINUTES PER INCH, BEFORE AND AFTER PLACEMENT. EFFECTIVE DIMENSIONS: LENGTH=615, WIDTH = 11.8', HEIGHT = 2.0' 9. ALL STONE MUST BE DOUBLE WASHED AND FREE FROM FINES AND ANY ORGANIC MATERIAL AND MUST HAVE LESS THAN 0.2 PERCENT MATERIAL FINER DESIGN DATA THAN A NUMBER 200 SIEVE. OHW OHW OHW OHW vn� �-OHW N31°16'5 " GAZEBO (TYP. OF 3) �_- z I I.c�C\TENNIS COURT PARCEL ID EXISTING 22-380-C POOLS 61,200 S.F. SEPTIC TANK O LEACH SYSTEM �Q 04 11.8x61.5 ` - -N _� CONC. WALK UP GONG _AMBER E GINGITYP) \ - O �I (&()() LOJ - -, WOOD BALCONY - r-----------�.�------ co / - SECOND FLOOR 0 _ O 0 OVERHANG 1s -- -- - - 1 s�s� 61.5' • LAWN \ �Di / i #60 EXISTING SEPTIC SYSTEM #3 _ J �_ / I CONDOMINIUM TO BE PUMPED DRY, REMOVED, LAMP \ FIN. FL. EL. = 17.5 AND DISPOSED OF PER TITLE 5 \ POST = I O SEPTIC VENT � CONC. WALL � / - _ _ - � J - \ / SECOND FLOOR � OVERHANG \ \ ? . ` - - - - - - - / PLANTING - - - - - - - / . 0 LO 0 / COVER- _ - r; _ - WOOD BALCONY - I' / 0 oo �( I �` TIMBER EDGING (TYP) COVER u - - o N PAVED \ / -14- - _ f _ F PARKING O EXISTING BUILDING z / / AOOD WOOD : WOOD WO ( � r ) OD WOOD WOOD WOOD -I WOOD CECK - O DECK IO I DECK DECK I( i DECK DECK IO I DECK I I DECK L_J \ ...., - i. i, , , . i z LAWN I o g \- APPROXIMATE LOCATION #60 PARCEL ID j 22-379 W \ GAZEBO 16 STOCKADE FENCE GARAGE O A' C r Z Z \ D m O 0 \ O \O �� z .,, , ,7// n G� I W LAWN OF SEPTIC SYSTEM CONDOMINIUM FAILED SEPTIC SYSTEM EXISTING MANHOLE /LAUNDRY o 0- �0 \ TP tit FROM TIE -CARD (TYP) FIN. FL. EL. = 14.1 LEACH PIT TO BE REMOVED �S) \� o ELEC. METER W Z 0 0 W W W o a n. \ , o \ r\\ 3 LU APPROXIMATE LOCATION OF WATER SERVICE PER p TOWN RECORDS UP �- FZ 306.00' oHW OHW -oHw -10 �..S 32° 16' 55" W OHW UP �- HYDRANT oHw `OHW OHW OHW OHW OHW o WATER GATE 0 MASSACHUSETTS AVENUE (40' WIDE - PUBLIC) ZI N �I I � PARCEL ID STOCKADE FENCE 0 22-381-1 J do UP G) Z O Q PAVED & _ DRIVEWAY CBDH OHW OHW OHW 0 WATER GATE POtfNB- JL I- ® FZ -OH -HYDRANT OHW WATER GATE w BENCHMARK MAG NAIL IN PAVEMENT ELEVATION = 12.03' NAVD88 0 10 20 40 SCALE: 1 "=20' 10. THE DESIGNER HAS NOT BEEN RETAINED BY THE CLIENT TO CONSTRUCT OR 1. TYPE OF ESTABLISHMENT: 14-BEDROOM CONDOMINIUM SUPERVISE THE CONSTRUCTION OF THE SYSTEM. THE CONTRACTOR IS RESPONSIBLE FOR MAKING ARRANGEMENTS FOR INSPECTION OF 2. SEPTIC TO SERVICE: 6 BEDROOMS INSTALLATION OF THE SYSTEM WITH THE LOCAL BOARD OF HEALTH. 1,111 S.F. OFFICE 3. SEWAGE SYSTEM DESIGN FLOW: 110 GALLONS PER BEDROOM = 110 x 6 = 660 GPD 11. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL HORIZONTAL AND VERTICAL CONTROL OF ALL SYSTEM COMPONENTS. 75 GALLONS PER 1,000 S.F. OF OFFICE = 1,111 = 84 GPD i000' 12. TIGHT JOINT PIPING MATERIAL TO CONSIST OF POLYVINYL CHLORIDE (P.V.C.) TOTAL = 744 GPD SCHEDULE 40, UNLESS OTHERWISE NOTED. 4. NOTE: THIS SEPTIC SYSTEM IS NOT DESIGNED FOR A GARBAGE GRINDER 13. THE CONTRACTOR SHALL NOTIFY THE DESIGN ENGINEER FOR CONSTRUCTION 5. SEPTIC TANK CAPACITY REQUIRED: 2 COMPARTMENTS, MINIMUM OF 200% OF DESIGN FLOW AND INSPECTION AFTER EXCAVATION FOR THE LEACHING BED (PRIOR TO THE 100% OF DESIGN FLOW PLACEMENT OF STONE) AND ALSO AFTER PLACEMENT OF PIPE &STONE PRIOR TO BACKFILLING. = 200% x 744 GALLON = 1,488 GAL, 100% x 744 = 744 GAL. (USE 2,500 GALLON 2 COMPARTMENT TANK) 6. DESIGN PERCOLATION RATE: ASSIGNED LESS THAN 5 MINUTES PER INCH 14. DESIGN ENGINEER SHALL CERTIFY CONSTRUCTION OF SYSTEM AND MATERIALS INSTALLED, THE CONTRACTOR SHALL PROVIDE A SIEVE ANALYSIS 7. SOIL ABSORPTION SYSTEM TYPE: CHAMBER SYSTEM OF THE FILL MATERIAL REQUIRED. AN AS -BUILT PLAN SHALL BE SUBMITTED TO 8. LEACHING AREA REQUIRED: MINIMUM 744 GPD /(0.74 GPD/S.F., CLASS ISOIL) = 1,006 S.F. THE LOCAL BOARD OF HEALTH UPON COMPLETION. 9. LEACHING SYSTEM PROPOSED: 61.5' LONG x 11.8' WIDE x 2' HIGH SYSTEM 15. NO RUBBER TIRE CONSTRUCTION MACHINERY SHALL DRIVE OVER THE BOTTOM AREA PROPOSED = 11.8' x 61.5' = 725.7 S.F. PROPOSED SEPTIC BED EXCAVATION DURING CONSTRUCTION. SIDE AREA PROPOSED = 2 x (11.8' + 61.5') x 2' = 293.2 S.F. 16. DIG -SAFE AND ALL OTHER NECESSARY AUTHORITIES SHALL BE NOTIFIED FOR THE PROPER LOCATION OF EXISTING UTILITIES PRIOR TO ANY EXCAVATION, TOTAL AREA PROPOSED = = 1,018.9 S.F. 10. LEACHING SYSTEM CAPACITY PROPOSED = 1,018.9 S.F. x 0.74 GPD/S G 17. WATER SERVICE LINE SHALL BE LOCATED AND MARKED PRIOR TO ANY EXCAVATING AND 10' MIN. SETBACK DISTANCE FROM SAID SERVICE TO THE SEPTIC SYSTEM SHALL BE MAINTAINED. SOIL EVALUATOR'S LOG 18. ALL WATER LINES WITHIN 10' OF SEPTIC SYSTEM COMPONENTS SHALL BE SLEEVED WITHIN 4" PVC SCHEDULE 40 PIPE. Depth from surface in inches Soil Horizon Soil Texture Soil Color (USDA) (Munsell) Soil Mottles and Depth Other Relative Factors TP#1 DEEP OBSERVATION HOLES TP#1 EL. 11.0 0-10 A LOAMY SAND 10 YR 4/1 10 - 29 Bw LOAMY SAND 10 YR 4/6 29 - 120 C1 MEDIUM SAND 2.5 YR 7J3 REDOX @ 74" PERCOLATION RATE _ < 2 MINUTES /INCH IN C1 LAYER DEPTH TO GROUNDWATER =NONE ENCOUNTERED, ADJUSTED HIGH GROUNDWATER = REDOX EL.= 4.8 (N4VD8 OBSERVATIONS BY: GLEN HARRINGTON, R.S. WITNESSED BY: PHIL RENAUD, HEALTH INSPECTOR DATE TESTED: MAY 25, 2023 GENERALNOTES tllllfti[ Q Ott t! Yarmouth Health Department mo•'M7 PRovED �°.�� NA ., Date NOTICE THIS PLAN MAY NOT BE ADDED T0, DELETED FROM, OR ALTERED IN ANY WAY BY ANYONE OTHER THAN CAPE 8 ISLANDS ENGINEERING, INC. REC E w /� � UNLESS AND UNTIL SUCH TIME AS AN ORIGINAL (RED) STAMP APPEARS ON THIS PLAN NO PERSON OR Y PERSONS, MUNICIPAL OR PUBLIC OFFICIAL MAY RELY UPON THE INFORMATION CONTAINED HEREIN: AND THIS ---'--� PLAN REMAINS THE PROPERTY OF CAPE AND ISLANDS ENGINEERING, INC. JUL 17.2023 \ \; COPYRIGHT (C) BY CAPE &ISLANDS ENGINEERING, INC. ALL RIGHTS RESERVED H tit# -DEFT. DATE DESCRIPTION BY CHK PREPARED FOR: ENGLEWOOD BEACH CONDOMINIUMS 60 BROADWAY STREET LOCATIONS ARE BASED ON AN "ON THE GROUND" INSi-RUMENT SURVEY AND ELEVATIONS BASED ON WEST YARMOUTH, MA 02673 THE NAVD 1988 DATUM. COORDINATE SYSTEM USED 6 THE MA -MAINLAND COORDINATE SYSTEM, PROJECT: DATUM: NAD 83, UNITS: U.S. SURVEY FEET. THE FINISHED FLOOR ELEVATION (FIN. FL. EL.) SHOWI HEREON IS BASED ON AN ASSUMED 1" LOWER 60 BROADWAY STREET THAN THE SURVEYED THRESHOLD ELEVATION. AN IN-ERIOR INSPECTION OF BUILDINGS WAS NOT PERFORMED. WEST YARMOUTH, MASSACHUSETTS ZONING DISTRICT: R-25 SHEET NO.: 1 OF 1 DATE: JUNE 2, 2023 PROPERTY IS LOCATED WITHIN AN AREA HAVING A ZWE DESIGNATION OF MINIMAL FLOOD HAZARD ZONE X, AE(ELEV. 11) BY THE FEDERAL EMERGENCY MANAGEMENT AGENCY (FEMA), ON FLOOD DRAWN BY: WNH CHECKED BY: MD INSURANCE RATE MAP NO. 25001 C0588J, WITH A MAPEFFECTIVE DATE OF JULY 16, 2014. PREPARED BY: THIS LOT i =LOCATE,-D)MTHIN A DEP APPROVED ;ONE II WELLHEAD PROTECTION AREA. THIS LOT IS NOT MAPPED WITHIN A MESA NATURAL HERITAGE AND ENDANGERED SPECIES AREA. � CAPE & 1 S L AN D S E N G I N E E R I N G WIND EXPOSURE CATEGORY: ZONE C SUMMERFIELD PARK 508.477.7272 PHONE DEED REFERENCE: BOOK 3183 PAGE 193 PLAN REFERENCE: BOOK 428 PAGE 65 800 FALMOUTH ROAD SUITE 301C MASHPEE, MA 02649 508.477.9072 FAX www.CapeEng.com OWNER: ENGLEWOOD BEACH CONDOMINIUMS � DRAWING TITLE: 60 BROADWAY STREET SEPTIC UPGRADE PLAN WEST YARMOUTH, MA 02673 (FOR SYSTEM #3 - NO INCREASE IN FLOW) ASSESSORS INFORMATION: MAP 22 PARCEL 380