HomeMy WebLinkAbout18 Standish Way septicLEGEND X 99. 1 EXIST. SPOT ELEV. -[99]--- PROPOSED CONTOUR 198.41 PROPOSED SPOT EL. TH1 0 TEST HOLE 2%, SLOPE OF GROUND UTILITY POLE FIRE HYDRANT NOTE NOT ALL SYMBOLS MAY APPEAR IN DRAWING ° SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED EXISTING 3 BEDROOM DWELLING DESIGN FLOW: 3 BEDROOMS ® 110 GPD = 330 GPD USE A 330 GPD DESIGN FLOW SEPTIC TANK: 330 GPD (2) = 660 USE A 1500 GAL. DUAL COMPARTMENT SEPTIC TANK 972 GAL. IN FIRST COMPARTMENT 480 GAL. IN SECOND COMPARTMENT LEACHING: SIDES: 2 (33.5 + 12.8) 2 (.74) = 137 GPD BOTTOM 33.5 x 12.8 (.74) = 317 GPD TOTAL: 614 S.F. 454 GPD USE (3� 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 4 STONE ALL AROUND SYSTEM PROFILE EKED ' ICQI�,ETICTAPE OR BE (NOT 10 Si&E) COMPARABLE MEANS FOR FUTURE LOCATION. ACCESS COVERS TO WITHIN 6" OF FIN. GRADE 2• PEASTONE OR GEOTEXTILE CONCRETE COVERS TO WITHIN 3" GRADE 20,30' FILTER FABRIC OVER STONE 17.0' MINIMUM 75' OF COVER OVER PRECAST 2X SLOPE REQUIRED OVER SYSTEM 16.0 PRECAST H-1D WATERTE D'BOX FOR LEVELNESS BLOCKS OR RISERS (1YP ) ST PRECAST RISERS MIN. 2 CKNESS 2'0 4"0SCH40 PVC MORTAR ALL INVERT IN 13.0' PIPES LEVEL 1ST 2' L4• COMPONENTS SIDES 13.83' i' I ENDS (TYP.) U_ 15M GAL DUAL 16.40' �k COUP. H-10 SEi�IC TAW 74• .°o°°°o°o o°o°o°°° _ ° TEE 33.54 6" MIN SUMP :°°°°°°°° ram ®'° °1� O°°°°�°°OHO '°O°O°O°O ® '°�°�°oo° °o°000°000°o 12" _MIN. INT. DIM.°° GAS BAFFLE GAS BAFFLE _ '-Oo�o9+oe°- •°o°o°000 4' LIQ. LEVEL 972 GAL COMP. GAL COMP.'. , :00000000 ":00°0°0°0 11.0 (ACME OR EQUAL) •; 8.8' 13.29 000°o° °oo�0000�o�o�o�o�000000000�o,°,o,°,o'°,o,°,o_�o�000ao� H-10 500 GAL. LEACHING CHAMBERS BY ACME PRECAST OR EQUAL 3/4"-1-1/2" DOUBLE WASHED STONE 4' MiN. (3) UNITS REQUIRED *THE INSTALLER SHALL VERIFY THE ALL AROUNC, PRECAST STRUCTURES LOCATIONS OF ALL UTILITIES AND ALL 6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 33.5' X 12.83' o BUILDING SEWER OUTLETS AND COMPACTION. (15221 [2]) ELEVATIONS PRIOR TO INSTALLING ANY r2.5 X SLOPE MIN.) (1.0 X SLOPE) (1_.0 X SLOPE) PORTION OF SEPTIC SYSTEM FOUNDATION- DBOX 12 15' SEPTIC TANK 25' ' ' LEACHING 6.0' BOTTOM TH-1 FACILITY NO GROUNDWATER FOUND KITCHEN RCD)M co I -F _IVING DINING 'ROOM. ROOM 1 ST FLOOR CRAWL SPACE ATTIC BE9- ROOM HALL ROOM CRAWL SPACE ATTIC 2ND FLOOR FLOOR PLAN NOT TO SCALE NOTES 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1 /8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-],Q 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER ' PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (811) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED BENEATH AND 5' AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. 13. OWNER'S ENGINEER TO PERFORM INSPECTIONS OF THE FINAL INSTALLATION. MINIMUM OF 24 HOURS NOTICE REQUIRED. LOCUS MAP SCALE 1 "=2000'f ASSESSORS MAP 30 PARCEL 32 LOCUS IS WITHIN FEMA FLOOD ZONE X (AREA OF MINIMAL FLOOD HAZARD) AS SHOWN ON COMMUNITY PANEL #25001 CO569J DATED 7/16/2014 SITE WITHIN STATE DESIGNATED NSA TEST HOLE LOGS ENGINEER: DANIEL E. GONSALVES, SE #1�587 WITNESS: BARRY LEWIS DATE: 5/16/2024 PERC. RATE - <�2a MIN/INCH CLASS I 'S_04LS- ELEV. 4 0» 16.5' A LS 12" 1OYR 4/2 LS 1OYR 5/6 30" ///// 14.0' PERC C1 MS 2.5Y 7/3 zUNSUITABLE SOIL 126" 6. 0'_ NO GROUNDWATER ENCOUNTERED TITLE 5 SITE PLAN OF Yar Department 18 STANDISH WAY Na E�+� WEST YARMOUTH, MA PREPARED FOR o� H OFMgSsgc DANIEL ct N o A. m� OJALA N0.40980 OP 9�0 SU VETO BORTOLOTTI CONSTRUCTION DANIEI.,� y�� THERINE STOECKER & DAVID SYLVIA O,JALFz ; - CIVIL N No.46502 10 .0 1,06�STE sO/ONAL ENG 1 1 �SH QF'�s� �,•cr+ of rz,,lss . DANIEL ". �i, o� DANIEL yG o OJALA� o� A. CIVIL OJALA No.76502 q No.40980 �aiOF�6�STE�C�oFFSS\o�� sS�OIVAL �Nv 9H0 SUR\1 Iq DATE DANIEL A. OJAL.A, P.E., P.L.S. DATE: JUNE 14, 2024 Scale:1 "= 20' v 20 3C 40 50 EEL' off 508-362-4541 fax 508-362-9880 JUL 0 2 2024 downcape.com down cope eagiaeering, INC. HEALTH DEPT civil engineers land surveyors SURVEY: Qk 939 Main Street ( Rte 6A) DRAFTED BY: PTT YARMOUTHPORT MA 02675 CHECKED BY: 24-115 130RT0--ST0ECKER-SYLV1A.D DCE ##24--115