Loading...
HomeMy WebLinkAbout74 Shaker Rd septic plansT.O.F. EL.- 45.6'f FINISHED GRADE @ FOUNDATION = 45.5'± PROP. SCH, 40 PVC SBAJ1ER_ PeIN 5L0P1.:,-1 1 Benchmark Nail in 24" Tree Elev. = 41.25' Approx. M.S.L. MAP 115 LOT 44 PROVIDE EXTENSION RISER WITH COVER OVER INLET & OUTLET TO WITHIN 6" OF F.G. 21" MIN- ACCESS COVER (3 TYP.)--\ FINISH GRADE OVER TANK EL.= 42.0'± 9" MIN. 36" MAX. `-PROP. SCH. 40 PVC SEWER MIN SLOPE A 19G. 38.2 OUTLET TEE 38.5- --I TEES TO BE CENTERED GAS BAFFLE 11.8 OFFSE+,III-F DIRECTLY UNDER RISERS 6" CRUSHED STONE I i OVER MECHANICALLY COMPACTED BASE C C C M C PROPOSED 1,500 GALLON CONCRETE SEPTIC TANK LENGTH 10'-0" WIDTH 51-81i DEPTH 5'-8of (Dimensions per V %� ) i L. L_ ACME/Shorey) NOT TO SCALE MAP 115 LOT 46.1 50, 595± S . F EXISTING LEACHING CATCH -BASIN 6�, 3" 1'3T" \- INLET TEE Q7 ! 85'. 00, f�77 'TT H (qp, I,y/ pE ` 0 wsE ROADEDGE\ _ N WAYS OF pEM 2" DROP MIN. ► - 3" DROP MAX. 3" 9" 14" 48" SITE PLAN SCALE 1" = 20' FINISH GRADE OVER D-BOX = 40.5' r--- REMOVABLE WATER -TIGHT COVER OVER RISER TO WITHIN 6" OF FINISHED GRADE 5" DIA. 0UTLET(S) I 9"MIN. 36"MAX. PROVIDE WATERTIGHT 4" PVC IN FROM JOINTS (TYP.) SEPTIC TANK 4 PVC OUT TO LEACHING FACILITY 1!LOVER 38.00' / M37.83' CRUSHED STONE MECHANICALLY COMPACTED BASE 5 OUTLET DISTRIBUTION BOX TO BE INSTALLED ON A LEVEL STABLE BASE. FIRST TWO FEET OF OUTLET PIPES TO BE LAID LEVEL. CROSS SECTION VIEW H-20 oto i III u i It�_jOv L)%,j)\ DETAIL NOT TO SCALE �Q •v ( a V Z � 0 FINISH GRADE OVER CHAMBERS = 39.4' - 40.51 GENERAL NOTES SLOPE @ 2% MIN. OVER SYSTEM 3/4" TO 1-1/2" DOUBLE WASHED 1. UNLESS OTHERWISE NOTED, ALL SYSTEM COMPONENTS AND CONSTRUCTION 4" SCHEDULE 40 PVC STONE TO CROWN OF PIPE METHODS SHALL BE IN ACCORDANCE WITH TITLE 5 OF THE STATE ENVIRONMENTAL MIN SLOPE 1% 2" OF 1/8" TO 1/2" DOUBLE WASHED CODE AND ANY APPLICABLE LOCAL RULES. STONE OR GEOTEXTILE FILTER FABRIC 2. ANY CHANGES TO THIS PLAN MUST BE APPROVED BY THE BOARD OF HEALTH AND THE ` DESIGN ENGINEER 1 TOP OF SAS = 38. j0' PLACE RISERS ON ALL 3. 4" SCHEDULE 40 PVC PIPE WITH WATER TIGHT JOINTS SHALL BE USED IN DISPOSAL 9" MIN. CHAMBERS WITH PIPED 3%.r3� 36" �v+� SYSTEM UNLESS OTHERWISE NOTED. I BREAKOUT EL = 38.00' INLETS TO WITHIN 6" OF FINISHED GRADE 1 4. TO PREVENT BREAKOUT, THE PROPOSED FINISHED GRADE SHALL NOT BE LESS THAN ELEVATION = 38.00' FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE SAS. UNLESS A 40 MIL GEOMEMBRANE LINER IS PLACE AT LEAST FIVE FEET FROM S.A.S. AND THE TOP OF O O O C%CICP O O o o THE LINER IS NOT LESS THAN THE BREAKOUT ELEVATION. o [ � D c� 5. SLOPE ALL SOLID P .O% MINA IMUM. oQ THIS SYSTEM IS T DESIGNED F _ _ o OR A GARBAGE DISPOSAL. 2' o o CDC:) 7. LOCAL BOARD OF HEALTH AND DESIGN ENGINEER TO BE NOTIFIED PRIOR TO BACK D CDC) FILL NG EN SYSTEM EARLY COMPLETE AND READY o Q a o 00 �o I NOT TO BEBACKFILLED I WITHOUT HOUT FIRST OBTAN OBTAINING APPROVAL FROM ROM BOARD OF HEALTH �� ka I AND DESIGN ENGINEER 4.0' m - - g-5' (TYP) - --- 4.0' i1 n' n n' B. EI EVATICOMS oncL_" nN,l %PPRO�((A�ATC RAC 1 rlAT1111A CCC RCAI/`t...lh��Pl! �I CVAT',,,N AcJ 4.0 I 4 83r I y.V Lt- 1 v U/'\JLV l!t flf V 1 1/'{ 1 L IYi. J. L. ✓r\ 1 L/tYl. ../t_L VLl.li/ 11V 1\ l tL /'\! IV 4 F7 (TYC7P.) SHOWN ON PLAN. 17-"35.50, HC-1-\ b 1--' ��H`C-t-2 I TOF=45.6'±--- . rn _v C7 a 0o m L 33.5 GROUND WATER ELEV.= < 28.60 9. CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS PRIOR TO CONSTRUCTION 12.83' THROUGH DIG -SAFE AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE AT 3 - 500 GALLON CHAMBERS 5' MIN. 1-888-DIG-SAFE AND ANY OTHER APPLICABLE AGENCIES, REPORT ANY DISCREPANCIES TYPICAL CHAMBER PROFILE CHAMBER END VIEW TO THE DESIGN ENGINEER. 6) N 3) SEPTIC DIMENSIONS & SWING -TIES SCALE: 1" = 20' SWING -TIES DESCRIPTION HC-1 HC-2 SEPTIC COVER IN (1) 41.5' 19.2' SEPTIC COVER OUT (2) 34.0' 15.1' CORNER OF STONE (3) 45.6' 29-0' CORNER OF STONE (4) 24.6' 33.4' CORNER OF STONE (5) 37.2' 44.2' CORNER OF STONE (6) 53.5' 40.9' NOTES: 1.) MAGNETIC MARKING TAPE SHALL BE PLACED ALONG THE TOP EDGE OF EACH SEPTIC SYSTEM COMPONENT. 2.) CONTRACTOR SHALL VERIFY SOIL CONDITIONS IN THE LOCATION OF THE PROPOSED LEACHING FACILITY TO ENSURE CONSISTENCY WITH TEST PIT DATA SHOWN ON THIS PLAN. REPORT TO ENGINEER AND LOCAL BOARD OF HEALTH IF SOILS ARE NOT CONSISTENT WITH TEST PIT DATA. 3.) PROPERTY IS LOCATED WITHIN A DEP Af-PROVED ZONE 11, 4.) SWING TIES SHOWN ON THIS PLAN ARE-ROVIDED ONLY AS A COURTESY FOR THE INSTALLER, INSTALLE" SHALL VERIFY SWING TIE MEASUREMENTS IN THE FIELD PRIOR TC INSTALLING THE SYSTEM. CONTRACTOR SHALL NOTIFY ENGINEER IF MEASUREMENTS APPEAR TO BE INCORREC' H_/-O CH r JETAILS 10. ALL JOINTS WHERE PIPE ENTERS AND EXITS CONC. STRUCTURES SHALL BE MADE WATERTIGHT NOT TO SCALE 11. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING TFST PIT - DATA REGULATIONS. OWNERIAPP LICANT IS TO OBTAIN SUCH DETERMINATION FROM �• • � - � APPROPRIATE AUTHORITY. i. • • •' 'Z PERC NO. N/A • ;� ,• . ',�/3 . ; W 12. ALL SEPTIC SYSTEM COMPONENTS SHALL WITHSTAND H-10 LOADING UNLESS LOCATED _- • .,;,� • U .�Tj,� INSPECTOR: Barry Lewis (BOH) UNDER MORE THAN 3 FEET OF COVER OR LOCATED UNDER PAVEMENT, DRIVES. OR armo • • • • , ••:. - ' • :. , • , i EVALUATOR: Michael Pimentel. EIT, CSE TRAVELED WAYS IN WHICH CASE THEY SHALL WITHSTAND H-20 LOADING. ••�� ^' '' • • • • " ••• ` r' C.S E. APPRO�eptember L DATE: Oct. 27, 1999 13. DOUBLE WASHED CRUSHED STONE SHALL BE FREE OF ALL DIRT, DUST AND FINES. 11 Vtttlll CCCFII •- ��" DATE: 17, 2024 • . j .�., • • 14, WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL LOAM, SUBSOIL AND UNSUITABLE f+r' • LOCUS l u TEST PIT #: 1 & 2 MATERIAL IN AREA BENEATH AND FOR 5 FT ON ALL SIDES OF LEACHING FACILITY. toes'' • •; � REPLACE ALL UNSUITABLE MATERIAL WITH CLEAN COARSE SAND FREE FROM CLAY. /� . •". ELEV TOP = 41.50' FINES OR OTHER UNSUITABLE MATERIAL IN ACCORDANCE WITH 310 CMR 15.255(3). 1 �`'' `. • . • ELEV WATER = < 30.50' ,� • 15. CONTRACTOR SHALL NOTIFY DESIGN ENGINEER OF ANY DISCREPANCIES FOUND IN }t '' • ' PERC RATE - SITE CONDITIONS FROM THOSE SHOWN PRIOR TO CONTINUATION OF WORK. • 16. PROPOSED PROJECT IS LOCATED WITHIN: i� r�: DEPTH OF PERC = • • ' .• ASSESSOR'S MAP 115 LOT 46.1 TEXTURAL CLASS: T `•`• •'. �,. _.11• r �Sia• ;, ;'•1 • • •�/ OWNER OF RECORD: VIDA R. MORRIS '� • ` ' • f` f' •' 00 1' ADDRESS: 74 SHAKER HOUSE ROAD no • ' • YARMOUTH PORT, MA 02675 • ^ • W114, " • • •/ • • • • v •• •• .p, # • Loamy Sand FEMA FLOOD ZONE X I i •irt7�� �fr .C.,�)� fl �.. A 10Yr3/1 COMMUNITY PANEL # 25001C0578J • • , 12" 40.50' 17. DEED REFERENCE BOOK 12386, PAGE 329 • ZONE I• •' ,�'� %• Loamy Sand 18, PLAN REFERENCE: PLAN BOOK 187. PAGE 149 • ~ �r� . ' f B 1 OYr 5/6 •• „ / �• �. 19. ALL DISTURBED AREAS SHALL BE RESTORED TO ORIGINAL CONDITION. 42" 38 00' 20. PROPERTY LINE INFORMATION IS ONLY APPROXIMATE. THIS PLAN IS TO BE USED ONLY •l•,J�'""`1 1tt FOR SEPTIC SYSTEM UPGRADE. JC ENGINEERING WILL NOT ASSUME ANY LIABILITY • •. L �!) %1(i� '� i FOR USES OF THIS PLAN OTHER THAN ITS INTENDED PURPOSE. •) i'i / •i✓+� il�" Q I nbern 21 OWNER / APPLICANT / CONTRACTOR SHALL BE RESPONSIBLE TO OBTAIN ANY AND ALL C / / I Med. to Coarse Sand 2.5Y 616 LOCUS PLAN SCALE 1" = 1000' 30-5U N ottling, Standing or Weeping Observed DESIGN DATA TEST = DAB; PERC NO. N/A NUMBER OF BEDROOMS (EXISTING 3 INSPECTOR: Barry Lewis (BOH) NUMBER OF BEDROOliAS (DESIGN 4 EVALUATOR: Michael Pimentel, EIT. CSE DESIGN FLOW 110 GA AY/BEDROOM C.S.E. APPROVAL DATE: Oct. 27, 1999 TOTAL DESIGN FLOW 440 GAUDAY DATE. September 17, 2024 DESIGN FLOW x 200 = 880 GAUDAY TEST PIT #: 3 & 4 USE PROPOSED 1,50 LLON SEPTIC TANK ELEV TOP = 39.60' ELEV WATER = < 28.60' PERC RATE = < 2 min./inch DEPTH OF PERC = 12" - 30" INSTALL 3 - 500 GAL. CHAMBERS w/ STONE TEXTURAL CLASS: I SIDEWALL CAPACITY (LENGTH + WIDTH) (2 SIDES) (2' HIGH) (0.7D/S.F.) = GAUDAY (33.5' x 12.83') (2) (2') (0,74 GPD/ S.F.) 37.1 GAUDAY 0" 39.60' Loamy Sand BOTTOM CAPACITY A 1 OYr 3/1 (LENGTH x WIDTH) (0.74 GPD/S.F. - GAUDAY 12" 38.60' (33.5' x 12.83') (0.74 GPD/S.F.) = 318.1 GAUDAY Perc 30 ) i 10' TOTALS: TOTAL NUMBER OF CHAMBERS 3 TOTAL LEACHING AREA 615.1 SOFT. TOTAL LEACHING CAPACITY GAL./DAY RESERVED FOR BOARD OF HEALTH USE B Loamy Sand I 10Yr 5/6 C 132" No�li l� REQUIRED PERMITS AND APPROVALS FOR THIS PROJECT. II 16 z Date LEGENE 50xO' EXISTING SPOT GRADE - - - 50 - EXISTING CONTOUR PROPOSED CONTOUR F5_0__j PROPOSED SPOT GRADE EXISTING GAS LINE EXISTING OVERHEAD UTILITIES F-77 - OCT 0 8 �OY4 EXISTING WATER LINE HEALTH DEPT. % TEST PIT LOCATION O O O PROPOSED 1,500 GALLON SEPTIC TANK PROPOSED 4" SOLID SCHEDULE 40 PVC PIPE Q PROPOSED H-20 DISTRIBUTION BOX QPROPOSED 500 GALLON H-20 LEACHING CHAMBER 34.60' ZN ❑r �tiv ro JOHN L. j cHUR,`!'.L R. Med. to Coarse Sand ' NO >ss 2.5Y 616 i 28.60' nding or Weeping Observed PROPOSED SEPTIC SYSTEM PLAN PREPARED FOR: ROBERT B. OUR CO., INC. LOCATED AT 74 SHAKER HOUSE ROAD YARMOUTH PORT, MA 02675 SCALE: 1 INCH = 20 FT DATE: OCTOBER 7, 2024 0 10 20 40 80 FEET PREPARED BY JC ENGINEERING, INC. 2854 CRANBERRY HIGHWAY EAST WAREHAM, MA 02538 508.273.0377 Drawn By JTC Designed By MCP Checked By AC JOB No. 8102