Loading...
HomeMy WebLinkAbout23 Gaslight Dr septic planTOF=18.3'± FINISHED GRADE @ FOUNDATION = 18.0'± EL.=14.25'-\ PROPOSED 4" PROVIDE EXTENSION RISER OVER INLET COVER TO WITHIN 6" OF F.G. AND MIDDLE & OUTLET TO F.G. DISCONNECT 21" MIN. ACCESS COVER (TYP. OF 2) JUNCTION --- BOX SCHEDULE 40 PVC 1 2" DROP MIN. I -" IN. SLOPE @ 1% 6" 3" 3" DROP MAX. 3" 9" � 1 ONNECTIC *15.2± 5-FT LIQUID DEPTH 13.00' co 7 ESHGW @ EL =9.9'± �.3' offset to fnd 1500 GALS. 1000 F.G. OVER 24"0 TANK EL-= 17.2' - 16.5' I12"MAX. i 9" MIN. 36"MAX. 2" PVC FORCE MAIN TO DISTRIBUTION BOX ROMDE WATER -TIGHT SEAL lf 12.75' DIMENSION AS PER ACME-SHOREY TANK TO BE WATER -PROOF AND WATER -TIGHT WITH EL.=7.25'-/ 22" ZABEL FILT POLYCLEFIN BACKED MODEL # A1801-4x22� 6" CRUSHED STONE EXTERIOR JOINT WRAP (GAS BAFFLE ON BOTTOM) OVER MECHANICALLY COMPACTED BASE PROP. 1500/1000 GAL. H-10 ART. I_ I,-ANK / PUMP CHAMBEP *CONTRACTOR TO VERIFY EXISTING LENGTH 12'-0" WIDTH 6'-6" DEPTH T-0" ELEVATION PRIOR TO ANY YVflRK & � p ALL TEES TO BE LINED UP NOTIFY NGINEER IF DIFFERENT. i'7 � P I � �` ` I I P R FILE DIRECTLY UNDER CENTER NOT TO SCALE OF RISER OPENINGS INSTALL 1-1/4" PVC TO HOUSE. JOINTS TO BE MADE NOTE: PUMP MUST BE EQUIPPED WITH A HIGH LEVEL ALARM WATERTIGHT. WIRE PUMP AND FLOATS TO SIMPLEX LOCATED IN THE BUILDING SERVED WHICH IS POWEREC BY CONTROL PANEL No. 1-CC2 NEMA-1 MFG. HOOVER A CIRCUIT SEPARATE FROM THE CIRCUIT TO THE PUMP. INSTRUMENTS HOISTING CABLE 7 x 19 STAINLESS NEMA 4 JUNCTION BOX CORROSION RESISTANT & STEEL 1/8" DIA. / 1,760 LB. STRENGTH LIQUID -TIGHT CABLE CONNECTORS SUPPORTED CONNECTORS SUPPORTED BY 1-1/4" PVC CONDUIT, 2" SCH. 40 TEE w/ CLEAN -OUT CAP JOINTS TO BE MADE WATERTIGHT 2" BALL VALVE w/ UNIONS SCH. 80 PVC GEORGE FISHER CO. MODEL NO.560 LO 3"-----2" SCH. 40 TO D-BOX (1% MIN. PITCH FROM D-BOX BACK TO P.C.) ALARM ON 1/4" WEEP HOLE IN DISCHARGE PIPE � i _ ,PUMP ON �' VP �% J, 0 2" BALL CHECK VALVE SCH. 80 PVC 100 1JPUMPI P.S.I. FLQWMATIC MODEL N0.2085 I OFF \- (2) WIDE ANGLE CONTROL FLOATS U N (BARNES 073618) 2" SCH. 40 PVC DISCHARGE PIPE 1: PUMP ON/OFF 120 ACTIVATION 2: ALARM ACTIVATION BARNES SE411 PUMP 0.4 H.P., 115 V, 2" DISCHARGE PASSING 1-1/2" SOLIDS OR EQUAL tD -1 Ou0/1000 GALLON SEPTIC TANK I PUIv � ti,,[AtAIVIOL DETAIL NOT TO SCALE BUOYANCY CALCULATIONS PROPOSED 1,500 / 1,000 GAL. TWO -COMPARTMENT H-10 SEPTIC TANK HIGH GROUNDWATER EL.= 9.90' TOP OF SEPTIC TANK EL. = 14.25' BOTTOM OF SEPTIC TANK EL. = 7.25' WATER DISPLACED = [9.90' - 7.25'1 x 12.00' x 6.50' = 207 C.F. WEIGHT OF DISPLACED WATER = 207 C.F. x 62.4 LB/C.F. = 12,917 LBS WEIGHT OF 1,500 / 1,000 GAL. 2-COMPARTMENT H-10 TANK = 24,000 LBS SOIL COVER =06.5'-14.25')x12.00'x6.50'=176C.F. WEIGHT OF SOIL ABOVE TANK = 176 C.F. x 110 LB/C.F. = 19,360 LBS 24,000 + 19,360 = 43,360 LBS > 12,917 LBS; THEREFORE OK / --1-FT FLOOR cS OVERHANG (1 HC-1 (FND)--,7%, 2) A�`�o O F 'Qi -HC-2 (FND) t SWING -TIES DESCRIPTION TANK COVER IN (1) TANK COVER OUT (2) CORNER OF STONE (3) CORNER OF STONE (4) CORNER OF STONE (5) CORNER OF STONE (6) (6 SWING -TIES & DIMS. SCALE: 1" = 30' HC-1 34.4' 39.4' HC-2 38.0' 33.4' HC-3 21.3' 35.3' 57.6' 50.3' HC-4 41.3' 49.9' 36.1' 22.9' LCBN J FINISH GRADE OVER D-BOX = 16.8'± REMOVABLE WATER -TIGHT COVER OVER RISER TO WITHIN 6" OF FINISHED GRADE 5" DIA. OUTLET(S) i MIN. 2" INLET TEE 36"MAX. L = 116 ± PROVIDE WATERTIGHT 2" PVC IN FROM ! JOINTS (TYP.) SEPTIC TANK 4" PVC OUT TO / LEACHING FACILITY 15.27' MIv. 6 15.10' 6" CRUSHED STONE OVER MECHANICALLY COMPACTED BASE 5 OUTLET DISTRIBUTION BOX TO BE INSTALLED ON A LEVEL STABLE BASE. FIRST TWO FEET OF OUTLET PIPES TO BE LAID LEVEL. CROSS SECTION VIEW DISTRi J IT DETAIL NOT TO SCALE NOTES: SLOPE @ 2%° MIN. OVER SYSTEM = 16. 8' - 16.5' PROP. VENT WITH CHARCOAL FILTER TO ABOVE GRADE GENERAL NOTES 40 MIL GEOMEMBRANE LlivtR, TUP 1=Lr=v. _ (Niis�. j-. 3/4" TO 1-1/2" DOUBLE WASHED �,\ 1. UNLESS OTHERWISE NOTED, ALL SYSTEM COMPONENTS AND CONSTRUCTION r- 4" SCHEDULE 40 PVC NOTE: CHAMBERS SHALL TOUCH ALONG - STONE TO CROWN OF PIPE METHODS SHALL BE IN ACCORDANCE WITH TITLE 5 OF THE STATE ENVIRONMENTAL MIN SLOPE 1% LONG SIDES AS SHOWN ON PLAN. 2" OF 1/8" TO 1/2" DOUBLE WASHED CODE AND ANY APPLICABLE LOCAL RULES. STONE OR GEOTEXTILE FILTER FABRIC 2. ANY CHANGES TO THIS PLAN MUST BE APPROVED BY THE BOARD OF HEALTH AND THE PLACE RISER ON ALL DESIGN ENGINEER. 1, MINTOP OF SAS = 15.73 CHAMBERS w/ PIPED 3. 4" SCHEDULE 40 PVC PIPE WITH WATER TIGHT JOINTS SHALL BE USED IN DISPOSAL 14.90' 36" MAX , INLETS TO WITHIN 6" SYSTEM UNLESS OTHERWISE NOTED. BREAKOUT EL = 15.40 OF FINISHED GRADE1 4. TO PREVENT BREAKOUT, THE PROPOSED FINISHED GRADE SHALL NOT BE LESS THAN ELEVATION = 15.40' FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE SAS. UNLESS A 40 MIL GEOMEMBRANE LINER IS PLACE AT LEAST FIVE FEET FROM S.A.S. AND THE TOP OF 0 (� 0 THE LINER IS NOT LESS THAN THE BREAKOUT ELEVATION. F-� C= C:)c 5. SLOPE ALL SOLID PIPE AT 1.0°Io MINIMUM. o C6. THIS SYSTEM I NOT DESIGNED FORA GARBAGE DISPOSAL. 0 0 oo CDC:)�� oo LOCAL BOARD OF HEALTH AND DESIGN ENGINEER TO BE NOTIFIED PRIOR TO BACK o C--1 60 0E= oo FILLING WHEN SYSTEM IS NEARLY COMPLETE AND READY FOR INSPECTION. SYSTEM IS 1 i oC)l I -5 0'y NOT TO BE BACK FILLED WITHOUT FIRST OBTAINING APPROVAL FROM BOARD OF HEALTH 3-0-�- :,0' (TYP) -1 3.0' 40, 40 (min.) j AND DESIGN ENGINEER. 6.0' 8. ELEVATIONS BASED ON NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD 88). SEE ! 45.0' (TYP.) BENCHMARK LOCATION AND ELEVATION AS SHOWN ON PLAN. 13.9 ' GROUND WATER ELEV= 9.90' mottlin 9. CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS PRIOR TO CONSTRUCTION 14.0' . � 4' MIN. REQ'D CHAMBER END VIEW � THROUGH DIG -SAFE AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE AT LC-6 CHAMBEI" TYPICAL CHAMBER PROFILE 1-888-DIG-SAFE AND ANY OTHER APPLICABLE AGENCIES. REPORT ANY DISCREPANCIES LINER TO BE INSTALLED PER PLAN y TO THE DESIGN ENGINEER. 1. MAGNETIC MARKING TAPE SHALL BE PLACED ALONG THE TOP EDGE OF EACH SEPTIC SYSTEM COMPONENT, 2. CONTRACTOR SHALL VERIFY SOIL CONDITIONS IN THE LOCATION OF THE PROPOSED LEACHING FACILITY TO ENSURE CONSISTENCY WITH TEST PIT DATA SHOWN ON THIS PLAN. REPORT TO ENGINEER AND LOCAL BOARD OF HEALTH IF SOILS ARE NOT CONSISTENT WITH TEST PIT DATA. 3. ENTIRE PROPERTY IS NOT LOCATED WITHIN A MASS DEP ZONE 11. 4. SWING TIES SHOWN ON THIS PLAN ARE PROVIDED ONLY AS A COURTESY FOR THE INSTALLER. INSTALLER SHALL VERIFY SWING TIE MEASUREMENTS IN THE FIELD PRIOR TO INSTALLING THE SYSTEM. CONTRACTOR SHALL NOTIFY ENGINEER IF MEASUREMENTS AQPEAR TO BE INCORRECT IN THE 1=iELv. 5. ELECTRIC LINES FROM PUMP CHAMBER TO CONTROL PANEL AT THE BUILDING SHALL BE INSTALLED BY THE CONTRACTOR. ELECTRIC LINES TO BE ROUTED FROM PUMA' CHAMBER TO BUILDING WITH THE LEAST DISTURBANCE TO THE PROPERTY AS POSSIBLE. EXISTING 12'x32' SAS FIELD TO BE DONED (APPROX. LOCATION) PROPOSED 1,500 / 1,O�t1G P IC TANK /PUMP CHAMBER r� ISTINu vi i (-;kL�.�. N SEPi iG i ANK r` TO BE ABANDONED PER 310 CMR 15.354 (i.e. PUMPED. BOTTOM OPENED \ I RUPTURED & FILLED w/ CLEAN SAND) MAP 149 LOT 4 15, 700± S.F. ' 19" \ ♦ �% ill H\ 1-FT FLOOR ^16 OVERHANG/ TOF= �'' 18.3'± a, SLAB= 16.0'+ STOOP 10 MAP 149 1/' LOT 5.1 PROPOSED v=t DISTRIBUTION BOX Q� ° 14x / _ ,10. P OPOSED 4" SCH 40 PVr, VENT; ACT LOCATION PER 0 ER ` 17 i REMOVE ALL UNSUITABLE 0" MATERIAL DOWN TO "B" SOIL & REPLACE w/ CLEAN COARSE SAND Pr-R 310 CMR 255(5) SITE PLAN orner of Stoop levation = 18.82' A.V.D.88 CHAMni 40 MIL GEOMEMBRANE LINER, 10. ALL JOINTS WHERE PIPE ENTERS AND EXITS CONC. STRUCTURES SHALL BE MADE WATERTIGHT. RFRNOT TO SCALE BOTTOM ELEV. = 10.4' (MAX.) 111. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING DETERMINATION FROM TEST PIT DATA REGULATIONS. OWNER/APPLICANT IS TO OBTAIN SUCH DETERM -.ykk APPROPRIATE AUTHORITY. ,w'- PERC NO. N/A I Q - - INSPECTOR: Barry Lewis (BOH) 1Z. ALL SEPTIC SYSTEM COMPONENTS SHALL WITHSTAND H-10 LOADING UNLESS LOCATED Cl r"--- - UNDER MORE THAN 3 FEET OF COVER OR LOCATED UNDER PAVEMENT, DRIVES, OR Poo ,. �� / � ,. T EVALUATOR: Michael Pimentel, EIT, CSE TRAVELED WAYS IN WHICH CASE THEY SHALL WITHSTAND H-20 LOADING. C.S.E. APPROVAL DATE Oct. 27, 1999 13. DOUBLE WASHED CRUSHED STONE SHALL BE FREE OF ALL DIRT, DUST AND FINES. /11 - DATE: Augur 2024 14. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL LOAM, SUBSOIL AND UNSUITABLE \ y� � TEST PIT #: 1 MATERIAL IN AREA BENEATH AND FOR 5 FT. ON ALL SIDES OF LEACHING FACILITY. -.` N ''"' : ELEV TOP = 14.40' REPLACE ALL UNSUITABLE MATERIAL WITH CLEAN COARSE SAND FREE FROM CLAY, Nll/ \ -- .� / FINES OR OTHER UNSUITABLE MATERIAL IN ACCORDANCE WITH 310 CMR 15.255(5). ` 7 ~ ...,/- ELEV WATER = 9.90' +� -� � � 15. CONTRACTOR SHALL NOTIFY DESIGN ENGINEER OF ANY DISCREPANCIES FOUND IN --- PERC RATE = 3 min./inch SITE CONDITIONS FROM THOSE SHOWN PRIOR TO CONTINUATION OF WORK. / Grays ,� a -.ar, � DEPTH OF PERC = 12" - 30" 16. PROPOSED PROJECT IS LOCATED WITHIN: Beach ' : ��� - ASSESSOR'S MAP 149 LOT 4 c -Y _ ,',` •\.\ • • • '" � '� � TEXTURAL CLASS: I OWNER OF RECORD: DAV1D & STEPHANiE COHEN �; ` - _- I -- CL N �C1 • '1 • ' �"' - p 25 PLOWGATE ROAD 12" a ( ,, Ii Perc LOCUS . ; ..n. "'- 32" •22 " 54" • t • k 7' eo LOCUS PLAN SCALE: 1" = 1000' 120" ♦ SL 2" FORCEMAIN ,l ♦ Or MIN. EACH SIDE OF WATER LINE CROSSING 115-N\� / O I ;♦ j kCHING CH-BASIN jjj P •o 29'j 4 '' L r r APPROX. " ._UTII-ITY - E/T/C 90xEs 14x7' 6 r MAP 149 LOT 3 00F/ PROPOSED j13) LC-6 CHAMBERS w/ STO PROP. MIL IMPERVIOUS GEOMEM&ANE LINER; TOP EL.=15.40'; BOT. EL.=10.40' DESIGN DATA NUMBER OF BEDROOMS (EXISTING) NUMBER OF BEDROOMS (DESIGN) 5 DESIGN FLOW 110 GALBEDROOM TOTAL DESIGN FLOW 550 GAUDAY DESIGN FLOW x 200 = 1,100 GAUDAY USE 1,500 GALLON FIRST COMPARTMENT OF PROPOSED 1500/1000 TANK INSTALL (13) LC-6 LEACHING CHAMBERS w/ STONE SIDEWALL CAPACITY (LENGTH + WIDTH) (2 SIDES) (1' HIGH) (0.74 GPD/S.F.) = GAL/DAY (45.0' + 14.0') (2) (1') (0.74 GPD/ S.F.) = 87.3 GAUDAY BOTTOM CAPACITY (LENGTH x WIDTH) (0.74 GPD/$ % = GAUDAY (45.0' x 14.0') (0.74 GPD/S.F.) 466.2 GAUDAY TOTALS: TOTAL NUMBER OF CHAMBERS 13 TOTAL LEACHING AREA 748:0 SQ.FT. TOTAL LEACHING CAPACITY GAL./DAY NOTE: CHAMBERS SHALL TOUCH ALONG LONG SIDES AS SHOWN ON PLAN. DOSING & STORAGE REQUIREMENTS DESIGN FLOW: 50 PD DOSING REQUIRED: 4 C S / DAY �--� 550 GPD / 4 = 137.5 GALS/CYCLE DISTANCE REQUIRED BETWEEN PUMP\ ON AND PUMP OFF FLOATS: 137.5 GALS/CYCLE - 200 GAUFT = 0.69 FT/CYCLE (USE 0.75' TO PROVIDE FOR BACKFLOW) STORAGE REQUIRED ABOVE WORKING LEVE 550 GAL STORAGE PROVIDED ABOVE WORKING LEVE 14.40 ADDRESS. 13.40' CHESTNUT HILL MA 02457 FEMA FLOOD ZONE X COMMUNITY PANEL# 25001CO576J 11.73' 17. DEED REFERENCE: BOOK 19347, PAGE 1 18. PLAN REFERENCE: P.B. 229, PG. 31 g,gp' 19. ALL DISTURBED AREAS SHALL BE RESTORED TO ORIGINAL CONDITION. 20. PROPERTY LINE INFORMATION IS ONLY APPROXIMATE. THIS PLAN IS TO BE USED ONLY 8.90, FOR SEPTIC SYSTEM UPGRADE. JC ENGINEERING WILL NOT ASSUME ANY LIABILITY FOR USES OF THIS PLAN OTHER THAN ITS INTENDED PURPOSE. 21. OWNER / APPLICANT / CONTRACTOR SHALL BE RESPONSIBLE TO OBTAIN ANY AND ALL REQUIRED PERMITS AND APPROVALS FOR THIS PROJECT. LEGEND 4.40' 50x0' EXISTING SPOT GRADE -- 50 - - -- 50 GAS W W -LSA- d O EXISTING CONTOUR OCT 0 8 2Q24 PROPOSED CONTOUR HEALTH DEPT PROPOSED SPOT GRADE EXISTING GAS LINE EXISTING OVERHEAD UTILITIES I EXISTING WATER LINE EXISTING LANDSCAPED AREA TEST PIT LOCATION EXISTING 1,000 GALLON SEPTIC TANK PROP. 1500/1000-GAL H-10 SEPTIC TANK / PUMP CHAMBER PROP. 2" SOLID SCHEDULE 40 PVC FORCE MAIN PROPOSED 4" SOLID SCHEDULE 40 PVC PIPE PROPOSED DISTRIBUTION BOX PROPOSED LC-6 LEACHING CHAMBER REV. DATE BY APP'D. DESCRIPTION PROPOSED SEPTIC SYSTEM UPGRADE pLsz+ OF �s��c PREPARED FOR JOHN L ROBERT B. OUR CO., INC. CHURCHILL JR., CIVIL `^ ., 066 LOCATED AT 23 GASLIGHT DRIVE YARMOUTH PORT, MA 02675 1 SCALE: 1 INCH = 20 FT. DATE: SEPTEMBER 15, 2024 I 0 10 20 40 80 FEET � OF a, JOHN LPREPARED BY a CHURCHILL JR. ' JC ENGINEERING, INC. NC 907 2854 CRANBERRY HIGHWAY ' EAST WAREHAM, MA 02538 508.273.0377 Drawn By: MCP Designed By: MCP Checked By: JLC JOB No. 7945