Loading...
HomeMy WebLinkAboutBHDC-24-13TEST PIT DATA TEST PIT DATA PERC NO. N/A PERC NO. N/A INSPECTOR: Barry Lewis INSPECTOR: Barry Lewis EVALUATOR: Michael Pimentel, EIT, CSE EVALUATOR: Michael Pimentel, EIT, CSE C.S.E. APPROVAL DATE: Oct. 27, 1999 C.S.E. APPROVAL DATE: Oct. 27, 1999 DATE: August 10, 2023 DATE: August 10, 2023 TEST PIT #: 1 TEST PIT #: 2 ELEV TOP = 25.90' ELEV TOP = 26.70' ELEV WATER = 18.90' ELEV WATER = 19.03' PERC RATE = PERC RATE = 2 min./inch DEPTH OF PERC = DEPTH OF PERC = 12" - 30" TEXTURAL CLASS: 1 TEXTURAL CLASS: 1 0° 12" B 36" 1 84" 1 08" 120" Loamy Sand 10Yr 3/1 Loamy Sand 10Yr 5/6 Medium to Fine Sand 2.5Y 6/6 Molliing 1 84 Standincq?a 'L 0 U J 25.90' 0" 6" 24.90' 12" 22.90' 42" M 18.90, 92" 16.90' 4 r, on, 1217' Fill Loamy Sand 10Yr 3/2 Loamy Sand 10Yr 5/6 Medium to Fine Sand 2.5Y 6/6 Mottlingja 92 - Standen 120" 26.70' 26.20' 25.70' 23.20' 19.03' 16.79 MAP 56 LOT 4 PROPOSED VENT AND BLOWER FOR FAST TANKS, EXACT LOCATION PER OWNER (TYP OF 2) PROPOSED 1,500 GALLON SEPTIC TANK "A" w/ MICROFAST INSERT MODEL 0 9-\ PROPOSED CLEAN -OUT- ./ PROPOSED 4" SCH. 40 PVC TO BE / CONNECTED AT BUILDING (1% MIN PITCH) (TYP FOR 3 BUILDING SEWER LINES)-', MAP 47 LOT 93 Benchmark #1 Corner of Step Elevation = 29.00' Approx. M.S.L. MAP 47 LOT 92 / MAP 47 i LOT 97 j MICROFAST NOTES 1 BLOWER MUST BE WITHIN 100 FEET (30.5m) OF FAST UNIT AND USE A MAXIMUM OF 4 ELBOWS IN THE PIPING SYSTEM (@ 100 FT). FOR DISTANCES GREATER THAN 100 FT --CONSULT FACTORY. BLOWER BASE MUST BE LOCATED ABOVE NORMAL FLOOD LEVELS. 2. VENT TO BE LOCATED ABOVE FINISH GRADE OR HIGHER TO AVOID INFILTRATION. CAP WITH 6" VENT GRATE W/AT LEAST 7.1 SO. IN OPEN SURFACE AREA. SECURE WITH STAINLESS STEEL SCREWS. OR: RUN VENT TO DESIRED LOCATION AND COVER OPENING WITH 3" VENT GRATE W/AT LEAST 7.1 SQ. IN. OPEN SURFACE AREA. SECURE WITH STAINLESS STEEL SCREWS. VENT MUST NOT ALLOW EXCESS MOISTURE BUILDUP OR BACK PRESSURE. 3. ALL APPURTENANCES TO FAST (e.g. SEPTIC TANK, PUMPOUTS, ETC.) MUST CONFORM TO ALL COUNTRY, STATE, PROVINCE, AND LOCAL CODES. 4. LOWER CONTROL SYSTEM BY BIO-MICROBICS, INC. 5. COPYRIGHT (C) 2001, BIG-MICROBICS, INC. 6. MUST INCREASE TANK SIZE BY 20% IF MINIMUM OF 10 INCHES IS USED BETWEEN THE UNIT AND THE BASE OF TANK CONSULT FACTORY FOR APPROVAL 7 THE PRIMARY COMPARTMENT MAY BE A SEPARATE TANK 8 FOUR LEG EXTENSIONS MAY BE USED TO STAND UNIT IN TANK ELIMINATING NEED FOR LID. 9. EITHER THE INFLUENT PIPE TEE SHALL BE FITTED WITH A PIPE CAP OR THE BAFFLE SEPARATING THE TWO ZONES SHALL BE EXTENDED ALL THE WAY TO THE TOP OF THE CONCRETE TANK. IF CHOOSING TO USE THE PIPE CAP, THEN THE BAFFLE SHALL BE AT LEAST 3" HIGHER THAN THE WATER LEVEL AS SHOWN ON THE DRAWING. 0)�� J CC) PROPOSED 4" VENT PIPE. I EXACT LOCATION PER OWNER i I / PROPOSED (17) 500 GALLON CONCRETE / LEACHING CHAMBERS / 4 FT OF I 1 I - w SURROUNDING STONE (CHAMBERS / TOUCHING ON LONG SIDES) ' O - ! I / O O _f o 20' 4 O ! 25x4' O O ,,J I/ - rt----PROPOSED O --`- \ DISTRIBUTION BOX O O > L_SA / PROPOSED WYE CONNECTION 18 I ♦ r LP DF - ` 22' I I 1 ' AMN W 20" 27x5' - TOF - - 32.6't D�rK - PROPOSED 1,500 GALLON SEPTIC TANK "B" w/ MICROFAST INSERT MODEL 0 9 UNIT #2OA UNI T � 27x4' (2-13EOSj #20,g ' I)E._; , r& j (2-BFDS. UN 21" Ir #20C � UM r Benchmark #2 UNIT Nail Set in 21" Tree #20E Elevation = 28.79' (2-BEDS) Approx. M.S.L. NIr �A' rY rt' �3 #20F` �'1 4 (2-SEDS � ..� � fir• EXISTING GAS LINE � (APPROX LOC ONLY)(TYP) W EXISTING 6" D I WATER MAIN (APPROX. LOCATION) `"~--. `,t/ EXISTING? TEL aO,x P. TRANSFC _�'MER-----ti -- SITE PLAN SCALE: 1" = 20' `!'' �' ►i� ;Y`� '+ _ GENERAL NOTES r f `Y 1r)t)�? t� 1. UNLESS OTHERWISE NOTED, ALL SYSTEM COMPONENTS AND CONSTRUCTION METHODS SHALL BE IN ACCORDANCE WITH TITLE 5 OF THE STATE ENVIRONMENTAL CODE AND ANY APPLICABLE LOCAL RULES. 2. ANY CHANGES TO THIS PLAN MUST BE APPROVED BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. ZONE II I ; Gravel 3. 4" SCHEDULE 40 PVC PIPE WITH WATER TIGHT JOINTS SHALL BE USED IN DISPOSAL Pi t:. SYSTEM UNLESS OTHERWISE NOTED. tlP (1 r' ,•, H' %. Q 4. TO PREVENT BREAKOUT, THE PROPOSED FINISHED GRADE SHALL NOT BE LESS THAN lit n , �t-� : •' " P �`, y �+ ELEVATION = 25.00' FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE SAS. UNLESS A 40 MIL GEOMEMBRANE LINER IS PLACE AT LEAST FIVE FEET FROM S.A.S. AND THE TOP OF !' THE LINER IS NOT LESS THAN THE BREAKOUT ELEVATION. "Ar, L 5, SLOPE ALL SOLID PIPE AT 1.0% MINIMUM. .5fiady 6. THIS SYSTEM IS NOT DESIGNED FOR A GARBAGE DISPOSAL. i F, ! o#41 S' 7. LOCAL BOARD OF HEALTH AND DESIGN ENGINEER TO BE NOTIFIED PRIOR TO BACK !'C t .S f FILLING WHEN SYSTEM IS NEARLY COMPLETE AND READY FOR INSPECTION. SYSTEM IS v r 5 NOT TO BE BACK FILLED WITHOUT FIRST OBTAINING APPROVAL FROM BOARD OF HEALTH AND DESIGN ENGINEER. 8. ELEVATIONS BASED ON APPROXIMATE M.S.L. DATUM. SEE BENCHMARK LOCATION AND LOCUS ;.- ELEVATION SHOWN ON PLAN. - •' %% `'� `"f 9. CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS PRIOR TO CONSTRUCTION ..'��'�(� •�`�" ."• \�` 1 THROUGH DIG -SAFE AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE AT :� `. • r . • ,� •'� 1-888-DIG-SAFE AND ANY OTHER APPLICABLE AGENCIES. REPORT ANY DISCREPANCIES a n be. r y . • ,� ,, � • .• y\ \� f, TO THE DESIGN ENGINEER. s •, /f / \�`:j 10. ALL JOINTS WHERE PIPE ENTERS AND EXITS CONCRETE STRUCTURES SHALL BE MADE WATERTIGHT. - --,•••y , + �'�0"• '" ,, 11. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING • , O 4 \tti > REGULATIONS. OWNER/APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM •\ \ �� 1. ` �/ \\ APPROPRIATE AUTHORITY. `• , • •��1 r.r.� V444 �� 12. ALL SEPTIC SYSTEM COMPONENTS SHALL WITHSTAND H-10 LOADING UNLESS LOCATED ,11 UNDER MORE THAN 3 FEET OF COVER OR LOCATED UNDER PAVEMENT, DRIVES, OR TRAVELED WAYS IN WHICH CASE THEY SHALL WITHSTAND H-20 LOADING. LOCUS PLAN 13 DOUBLE WASHED CRUSHED STONE SHALL BE FREE OF ALL DIRT DUST AND FINES SCALE: 1" = 1000' 14. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL LOAM, SUBSOIL AND UNSUITABLE MATERIAL IN AREA BENEATH AND FOR 5 FT. ON ALL SIDES OF LEACHING FACILITY, REPLACE ALL UNSUITABLE MATERIAL WITH CLEAN COARSE SAND FREE FROM CLAY, FINES OR OTHER UNSUITABLE MATERIAL IN ACCORDANCE WITH 310 CMR 15.255(3). 15. CONTRACTOR SHALL NOTIFY DESIGN ENGINEER OF ANY DISCREPANCIES FOUND IN SITE CONDITIONS FROM THOSE SHOWN PRIOR TO CONTINUATION OF WORK. 16. PROPOSED PROJECT IS LOCATED WITHIN: ASSESSOR'S MAP 47 PARCEL 97 NOTES: OWNER OF RECORD: HALCYON CONDOMINIUMS c/o ADDRESS: 300 BUCK ISLAND ROAD 1.) MAGNETIC MARKING TAPE SHALL BE PLACED Al ONG THE TOP EDGE OF EACH SEPTIC W. YARMOUTH, MA o2673 SYSTEM COMPONENT. FEMA FLOOD ZONE X 2.) CONTRACTOR SHALL VERIFY SOIL CONDITIONS IN THE LOCATION OF THE PROPOSED COMMUNITY PANEL # 25001CO586J LEACHING FACILITY TO ENSURE CONSISTENCY WITH TEST PIT DATA SHOWN ON THIS PLAN. REPORT TO ENGINEER AND LOCAL BOARD OF HEALTH IF SOILS ARE NOT CONSISTENT WITH 17. DEED REFERENCE: LAND COURT CERTIFICATE #157445 TEST PIT DATA. 18. PLAN REFERENCE: LAND COURT PLAN #32462-D-5 3.) PORTION OF PROPERTY IS LOCATED WITHIN A MASS. DEP APPROVED ZONE it. ALL WORK IS 19. ALL DISTURBED AREAS SHALL BE RESTORED TO ORIGINAL CONDITION. LOCATED WITHIN ZONE 11. 20. PROPERTY LINE INFORMATION IS ONLY APPROXIMATE. THIS PLAN IS TO BE USED ONLY 4.) SWING TIES SHOWN ON THIS PLAN ARE PROVIDED ONLY AS A COURTESY FOR THE FOR SEPTIC SYSTEM UPGRADE. JC ENGINEERING WILL NOT ASSUME ANY LIABILITY INSTALLER- INSTALLER SHALL VERIFY SWING TIE MEASUREMENTS IN THE FIELD PRIOR TO FOR USES OF THIS PLAN OTHER THAN ITS INTENDED PURPOSE. INSTALLING THE SYSTEM. CONTRACTOR SHALL NOTIFY ENGINEER IF MEASUREMENTS APPEAR TO BE INCORRECT. 21 CONTRACTOR SHALL BE RESPONSIBLE TO OBTAIN ANY AND ALL REQUIRED PERMITS AND APPROVALS FOR THIS PROJECT, 5.) ELECTRIC LINE FROM BLOWER TO CONTROL PANEL AT THE BUILDING SHALL BE INSTALLED BY THE CONTRACTOR. ELECTRIC LINE ROUTE SHALL BE ALIGNED SO AS TO CREATE THE LEAST AMOUNT OF DISTURBANCE TO THE PROPERTY AS POSSIBLE. 6.) NEW SEPTIC SYSTEM WAS DESIGNED PER MASS DEP LETTER DATED JUNE 4, 2003 ON FILE WITH THE YARMOUTH BOARD OF HEALTH. ' P ,,,--PROPOSED SAS • f BUILDING 20 r MAP 47 LOT 97 ealth Department Yarmouth H OvED Date Name / 0p0 O� 0� INDEX PLAN SCALE: I " = 200' LEGEND 50xO EXISTING SPOT GRADE - - 50 EXISTING CONTOUR - E5V 1 PROPOSED CONTOUR EXISTING UNDERGROUND ELECTRIC EXISTING UNDERGROUND TELEPHONE / CABLE EXISTING 6" D.I. WATER MAIN EXISTING WATER SERVICE LINE EXISTING GAS LINE TEST PIT LOCATION EXISTING 1,000 GALLON SEPTIC TANK PROPOSED 4" SOLID SCHEDULE 40 PVC PIPE PROPOSED 5-OUTLET DISTRIBUTION BOX PROPOSED 500 GALLON LEACHING CHAMBER Q� PROPOSED 1,500 GALLON SEPTIC TANK wl MICROFAST INSERT REV. I DATE I BY I APP'D. I DESCRIPTION PROPOSED SEPTIC SYSTEM UPGRADE w`NS�c PREPARED FOR: JOHN L. ��, ROBERT B. OUR CO., INC. o CHURCHILL JR. CIVIL NO 48066 LOCATED AT rsT" 300 BUCK ISLAND ROAD (BUILDING #20) W. YARMOUTH, MA 02673 PAGE 1 OF 2 SCALE: 1 INCH = 20 FT. DATE: NOVEMBER 6, 2023 0 10 20 40 80 FEET �ZN OF NgS3 ram` J{iHN L. yes PREPARED BY: CHURCHILL JR. JC ENGINEERING, INC. CIVIL '^ N 41807 2854 CRANBERRY HIGHWAY " EAST WAREHAM, MA 02538 508.273.0377 Drawn By: MKV Designed By: MCP Checked By: JLC ! JOB No. 4977-1