HomeMy WebLinkAboutBHDC-24-13 disposal systemTOP OF FOUNDATION ELEV.= VARIES INISH GRADE @ FND. = VARIES (SEE EXIST. 4" BUILDING SEWER LINE TO ACCESS TO INSPECT PUMP OUTS BLOWER WITH HOOD (BY MUST BE PROVIDED BIO-MICROBICS) SEE DETAIL 6" OBSERVATION PORT FINISH GRADE 29.0' - 28.2, OVER TANK EL. = (A ) LT'N. VENTING PIPE: 27.9'- 27.7' BVX4r MOUNTING- ELECTRICAL CONDUIT �8E REPLACED w/ 4" SCH. 40 PVC I HARDWARE, 2"MM BLOWER PIPING (TO BLOWER CONTROL JOINT � - � SYSTEM) SEE NOTE 4- SEE NOTE 9. MUST BE WATERTIGH PROP. 4" SCH. 40 PVC MIN. PITCH) T _ I I I' 5" (1% 1.25 15" V. .�. 3" MIN. *28.2'± (Al 47.5" 26.00' \ /A) ' 26. 8'± (A,e , 6" DIA. HOLE SEE NOTE 3 25.75' (A) *26. V+ (B, 25.75' (B) _ _ I I f 25. 50 B ( ) i SETTLING ZONE 24" TREATMENT lZONE 0" - 16.8' OFFSET TO FND. (A) -17. OFFSET TO FND. (B) ---I I 1 MIN. SEE NOTE 6 MICRO FAST INSERT BY BID-MICROBICS) PROPOSED 1,500 GALLON CONCRETE SEPTIC TANK WITH MICROFAST INSERT SEPTIC I ,ANK PRGI- IL_E NOT TO SCALE SWING -TIES DESCRIPTION DC-1 DC-2 DC-3 SEPTIC TANK COVER IN (' 97 33.9' -- SEPTIC TANK CENTER ENO (2) 16.3' 25.9' -- SEPTIC TANK COVER IN (3) -- 7.6' 24.0' SEPTIC TANK CENTER END (4) - 16.6' 31.4' CORNER OF STONE (5) 37.7' 25.4' 41.5' CORNER OF STONE (6) 29.1' 35.6' 54.7' CORNER OF STONE (7) 94.1' 93. V 105.2' CORNER OF STONE (8) 105.9' 90.1' 94.5' CORNER OF STONE (9) 91.7' 73.8' 78.0' 0 N 0 v N M z Q J a U I MAP 56 LOT 4 PROPOSED VENT AND BLOWER FOR FAST TANKS EXACT LOCATION PER OWNER (TYP OF 2) - PROPOSED 1,500 GALLON SEPTIC TANK / "A" w/ MICROFAST INSERT MODEL 0 9-\ PROPOSED CLEAN -OUT PROPOSED 4' SCH 40 PVC TO BE CONNECTED AT BUILDING (1% MIN. PITCH) (TYP FOR 3 BUILDING SEWER LINES) MAP 47 LOT 93 MAP 47 LOT 92 *CONTRACTOR TO VERIFY EXISTING ELEVATION PRIOR TO ANY WORK & NOTIFY ENGINEER IF DIFFERENT. FINISH GRADE OVER D-BOX = 27.3't REMOVABLE WATER -TIGHT COVER OVER / RISER TO WITHIN 6" OF FINISHED GRADE 1 5" DIA. OUTLET(S) I 9" MIN. 36" MAX. L=39'± (B) PROVIDE WATERTIGHT 4" PVC IN FROM JOINTS ITYP.) SEPTIC TANK 0 4" PVC OUT TO LEACHING FACILITY 12" 25.00' MIN. 24.83' 6" CRJSHED STONE OVER MECHANICALLY COMPACTED BASE 5 OUTLET DISTRIBUTION BOX TO BE INSTALLED ON A LEVEL STA15LE BASE. FIRST TWO FEET OF OUTLET PIPES TO BE LAID LEVEL. CROSS SECTION VIEW DIS i t lt�u I ii:04 hi DETAIL NOT TO SCALE MAP 47 LOT 97 1 i FINISH GRADE OVER CHAMBERS = 28.0' - 26.5' SLOPE @ 2% MIN. OVER SYSTEM 4 SCHEDULE 40 PVC MIN SLOPE 1% 9"MIN. TOP OF SAS = 25.3T 24tOU 50' 36"MAX. BREAKOUT EL = 25.00' 0CDC)6904.83' (TYP) 4.0' - VARIES 5' MIN. REQ'D 3.47' PROP.* Z022.50' GROUND WATER ELEV.= 19.03' mottlin (17 - 500 GALLON CHAMBERS TYPICAL CHAMBFR PROF111-1= . NOTE: CHAMBERS SHALL TOUCH ON LONG SIDES AS SHOWN ON PLAN. -F ISM H � F T A I US - --_ _ NOT TO SCALE 1 � � I � i PROPOSED 4" VENT PIPE / / EXACT LOCATION PER OWNER / / PROPOSED 5X GALLON CONCRETE f I / - " LEACHING CNAJAIIBER � EXISTING 6" D I WATER MAIN (APPROX. LOCATION)- its i isti I EI !_l/�, •_t SITE PLAN_ SCALE- 1" = 20' wt 4-FT OF / f SURROUNDING STONE 1. #-"BERS / TOUCHING ON LONG S,IDESi / O O O G /ram % ! 25x4' .-PROPCSED DIS RIBJTIION BOX %t 26x6' \ / -_,--T-PROPOSED MrYE CONNECTION - I 18" I _ I�MF'E NE i� 2C 327x56' PROPOSED 1.500 GALL ON SEPTIC TANK "9" w, MICROFAST iN'SER' MODEL 0 9 W---_..... W �� / I4 BEDS) ' UNIT I { #20C f UNIT 1 2-BEDs) I #20D 1 (2-BEDS) r' I UIf NIT 1 #20E 1 SWING -TIES & DIMS. SCALE: 1" = 20' BLOWER W/ HOOD (BY BIO-MICROBICS) ,ii�lll 1 ELECTRICAL CONDUIT • BLOWER CONTROL PIPIUG SYSTEM) BLOWER DETAIL NOT TO SCALE OPENING FOR FAST MODULE TO SIT IN TANK u - 2-5/8 2.5" 49.25" MIN. 25" -=-- 500 GALLON ! 60" MIN. LIQUID G CAPACITY 1000 GALLON MIN. LIQUID CAPACITY SEPTIC TANK SEE NOTE 3 1,500 GALLON SEP-I IC TANK W/ MICROFAST INSERT (MODEL 0.9) NOT TO SCALE PROP. VENT WITH CHARCOAL FILTER TO ABOVE GRADE 3/4" TO 1-1/2" DOUBLE WASHED STONE TO CROWN OF PIPE 2" OF 1/8" TO 1/2" DOUBLE WASHED STONE OR GEOTEXTILE FILTER FABRIC PLACE RISERS ON ALL CHAMBERS WITH INLET PIPES TO WITHIN 6" OF F.G.1 --- o0 0CD 000� CD o� oQ 0 Qo V.✓ - (TYP.) 16.5' CI- AIBE� Lfsio Vitzvv *Depth to groundwater may be reduced by up 2 feet as allowed under STANDARD CONDITIONS FOR SECONDARY TREATMENT UNITS APPROVED FOR REMEDIAL USE (Last Revision Date: November 30, 2016), SECTION II(5)(b) ALTERNATIVE DESIGN STANDARDS, DESIGN DATA NUMBER OF BEDROOMS (TOTAL) 12 DESIGN FLOW 110 GAUDAY/BEDROOM TOTAL DESIGN FLOW 1,320 GAUDAY TANK "A" NUMBER OF BEDROOMS 6 DESIGN FLOW 110 GAUDAY/BEDROOM TOTAL DESIGN FLOW 660 GAUDAY USE PROPOSED 1,500 GAL. SEPTIC TANK W/ MICROFAST INSERT TANK "B" NUMBER OF BEDROOMS 6 DESIGN FLOW 110 GAUDAY/BEDROOM TOTAL DESIGN FLOW 660 GAUDAY USE PROPOSED 1,500 GAL. SI :PTIC TANK W/ MICROFAST INSERT * Per DEP General Use Certification fetter The MicroFAST@ 0.9 is installed in the second compartment of a two -compartment tank with a total liquid capacity of at least 1, 500 gallons constructed in accordance with 310 CMR 15.226. INSTALL (17) 500 GALLON CHAMBERS W/ STONE SIDEWALL CAPACITY (TOTAL PERIMETER) (2' HIGH) (0.74 GPD/S.F.) = GAUDAY (213.2') (7) (0.74 GPD/ S.F.) = 315.5 GAUDAY BOTTOM CAPACITY (FOOTPRINT AREA) (0.74 GPD/S.F.) = GAUDAY (1,487 S.F.) (0.74 GPD/S.F.) = 1,10OA GAUDAY TOTALS: TOTAL NUMBER OF CHAMBERS 17 TOTAL LEACHING AREA 1,913.4 SQ.FT. TOTAL LEACHING CAPACITY 1,415.9 GAL./DAY LEGEND 50xO EXISTING SPOT GRADE - - - 5C EXISTING CONTOUR 50 PROPOSED CONTOUR EXISTING UNDERGROUND ELECTRIC EXISTING UNDERGROUND TELEPHONE / CABLE EXISTING 6" D.I. WATER MAIN EXISTING WATER SERVICE LINE EXISTING GAS LINE % TEST PIT LOCATION EXISTING 1,000 GALLON SEPTIC TANK PROPOSED 4" SOLID SCHEDULE 40 PVC PIPE 0 PROPOSED 5-OUTLET DISTRIBUTION BOX PROPOSED 500 GALLON LEACHING CHAMBER =0= PROPOSED 1,500 GALLON SEPTIC TANK w/ MICROFAST INSERT REV. DATE BY APP'D. DESCRIPTION OF F 9�• tiG = JOHN L. v' CHURCHILL JR. CIVIL N0. 4 0066 \�� 1ST _ JOHN o + CHURCHILL JR. " I C1V1L '^ NO. PROPOSED SEPTIC SYSTEM UPGRADE PREPARED FOR: ROBERT B. OUR CO., INC. LOCATED AT 300 BUCK ISLAND ROAD (BUILDING #20) W. YARMOUTH, MA 02673 PAGE 2 OF 2 SCALE. 1 INCH = 20 FT. DATE: NOVEMBER 6, 2023 0 10 20 40 80 FEET PREPARED BY: JC ENGINEERING, INC. 2854 CRANBERRY HIGHWAY EAST WAREHAM, MA 02538 508.273.0377 Drawn By: MKV Designed By: MCP Checked By: JLC JOB No. 4977-1