HomeMy WebLinkAboutBHDC-24-188 disposal systemI
ROUTE 28
STATE IIIGW AY 80' W I DE)
STATE y NAyoUT #
3180
(1936 STATE ALTERATION
\Si\.f; -
C r� `.
r
1297 ROUTE 28
MAP 60 PARCEL 169
N/F
,6R/AN MCLAUGHLIN
EXISTING SEPTIC
TANK TO REMAIN
0
DOEXISTING
DISTRIBUTION BOX
O TO BE REMOVED
O
EXISTING CESSPOOLSoTO BE
OR ABANDONED IN
yREMOVED
PLACE PER BOARD OF
y
HEALTH REQUIREMENTS
PROPOSED DISTRIBUTION BOX a
p
2 OUTLET (H20) o
V �
d
PROPOSED SOIL ABSORPTION SYSTEM
(2) 500 GALLON LEACHING CHAMBERS (H20)
W/2.0' STONE SURROUND
(8.83' x 21.0')
0
0
0
o�
0
Aliclnlic( DESIGN
P.O. Box 10�1, Sandwich, MA 02563
U E ET
IAn
AL S,TwiDE)
AT ,
(pRIV
ENGINEERS, INC.
(508) 888 - 9282
Designed by
Drawn by :
Checked by
Survey chk. b}
Approved by :
ONW
OHW
NW
r.
OHW
LEGEND
EOP
EXISTING
EDGE OF PAVEMENT
CCB
EXISTING
CAPE COD BERM
#7
EXISTING
UTILITY POLE W/ NUMBER
4-
EXISTING
GUY WIRE
-OHW
EXISTING
OVERHEAD WIRES
EXISTING
WATER GATE
-W --
EXISTING
WATER LINE
-GAS--
EXISTING
GAS LINE
.��Y,
EXISTING
TREE LINE
7D_
EXISTING
SIGN
EXISTING
BENCHMARK
0 0
EXISTING
SURVEY MONUMENTS FOUND
EXISTING
1 FOOT MAJOR CONTOUR LINE
EXI` Tlf
�r,T t�?'."!^`. �' TO,
EXISTING
TEST PIT
.,.,
PROPOSED
1 FOOT MAJOR CONTOUR LIN
PROPOSED
5 FOOT MINOR CONTOUR LINE
--W --
PROPOSED
WATER LINE
-GAS--
PROPOSED
GAS LINE
-OHW
PROPOSED
OVERHEAD WIRES
FINISHED FLOOR
ELEVATION=25.7'
SEPTIC NOTES:
1. ALL DIMENSIONS ARE PERPENDICULAR TO THE PROPERTY LINES.
2. ALL SYSTEM COMPOVENTS SHALL BE INSTALLED IN COMPLIANCE
WITH THE STATE SANITARY CODE TITLE V AND THE LOCAL BOARD
OF HEALTH REQUIREMENTS.
3. ANY CHANGE TO THIS PLAN MUST BE APPROVED BY THE BOARD
OF HEALTH AND DESIGN ENGINEER.
4. BEFORE BACKFILLING THE SYSTEM, THE CONTRACTOR SHALL
NOTIFY THE DESIGN ENGINEER AND BOARD OF HEALTH TO
INSPECT.
5. HEAVY EQUIPMENT SHALL NOT TRAVEL OVER DISPOSAL SYSTEM
DURING OR AFTER CONSTRUCTION.
6. TIGHT JOINT (T.J.) PIPING SHALL CONSIST OF POL"VINYL CHLORIDE
(PVC) PIPE, SCHEDULE 40. ALL PIPES TO BE LAID ON FIRM BASE
AND TO BE WATERTIGHT. ALL CONNECTIONS AND JOINTS SHALL_ BE
MECHANICALLY SOUND AND TIGHT.
7. DISTRIBUTION BOX SHALL BE WATER TESTED FOR LEVELNESS.
DISTRIBUTION BOX SHALL HAVE AN INLET TEE EX ENDING TO ONE
INCH ABOVE THE OUTLET INVERT ELEVATION.
8. THE DESIGN ENGINEER SHALL CERTIFY INSTALLATION.
9. EXISTING LOT SERVED WITH TOWN WATER SERVICE.
10. CONTRACTOR SHALT_ REMOVE ALL UNSUITABLE MATERIALS
(ORGANICS, FILL, A AND B LAYER SOILS) WITHIN 5 FEET ALL
AROUND AND UNDhR THE PROPOSED LEACHING FIELD AND
REPLACE WITH SAND CONFORMING TO 310 CMR 15,255(3).
TEST PIT #1 - ELEVATION=22.50'f:
DEPTH
BOTTOM
SOIL
SOIL
REDOXIMORPHIC
FROM
OF LAYER
SOIL
TEXTURE
COLOR
FEATURES
OTHER
SURFACE
ELEV.
HORIZON
(USDA)
(MUNSELL)
(MOTTLES)
(INCHES)
(FEET)
0-18
21.00
FILL
-
-
NONE
-
18-24
20.50
0
SANDY LOAM
10YR 3/2
NONE
FRIABLE
24-28
20.17
A
SANDY LOAM
10YR 3/3
NONE
FRIABLE
LOOSE
28-40
19.17
B
LOAMY
SAND
10 YR 4 6
/
NONE
40-138
11.00
C
MEDIUM
SAND
10 YR 5/4
NONE
LOOSE
PERCOLATION TEST BY: DAVID COUGHANOWR
CONTRACTOR FOR ATLANTIC DESIGN ENGINEERS, INC.
WITNESSED BY: BARRY LEWIS, YARMOUTH HEALTH DIVISION
DATE: 09/25/2024
PERCOLATION RATE: N/A
DEPTH; TO GROUNDWATER: NO GROUNDWATER OBSERVED
TEST PIT #2 - ELEVATION=21.50'f
DEPTH
BOTTOM
SOIL
SOIL
REDOXIMORPHIC
FROM
OF LAYER
SOIL
TEXTURE
COLOR
FEATURES
OTHER
SURFACE
ELEV.
HORIZON
(USDA)
(MUNSELL)
(MOTTLES)
(INCHES)
(FEET)
0-16
20.17
FILL
-
-
NONE
-
16-22
19.67
0
SANDY LOAM
10YR 3/2
NONE
FRIABLE
22-28
19.17
A
SANDY LOAM
10YR 3/3
NONE
FRIABLE
28-38
18.33
B
LOAMY
SAND
10 YR 4/6
NONE
LOOSE
38-132
10.50
C
MEDIUM
SAND
10 YR 5/4
NONE
LOOSE
PERCOLATION TEST BY: DAVID COUGHANOWR
CONTRACTOR FOR ATLANTIC DESIGN ENGINEERS, INC.
WITNESSED BY: BARRY LEWIS, YARMOUTH HEALTH DIVISION
DATE: 09/25/2024
PERCOLATION RATE: 2 MINUTES PER INCH IN C SOILS
DEPTH TO GROUNDWATER: NO GROUNDWATER OBSERVED
-EXISTING SEPTIC TANK -
(TO REMAIN)
a F.G.=24.80'f F.G.= 23.90't
a
_ I "
IN OUTLET TEE
EX. a
19.97 INLET TEE
ELEV.
GAS BAFFLE -
L
� a A
CONTRACTOR TO VERIFY
AND NOTIFY ENGINEER IF
DISCREPANCY IS FOUND
2 OUTLET
-DISTRIBUTION BOX-
(H20)
EXISTING RISER AND COVER TO
FINISHED GRADE i
F.G.=22.50't
GENERAL NOTES:
1. RECORD OWNER(S) PER BARNSTABLE COUNTY REGISTRY OF DEEDS BOOK 1441
PAGE 90:
MAP 60 PARCEL 168 (1301 ROUTE 28)
VSH REALTY, INC.
WESTBOROUGH, MA 01581
AREA = f0.42 ACRES
2. THE SUBJECT PROPERTY IS SHOWN AS PARCEL 168 ON THE TOWN OF YARMOUTH
ASSESSOR'S MAP 60. TOTAL LAND AREA IS t0.42 ACRES.
3. THE PROPERTY LIES WITHIN A BUSINESS 1 (B1) ZONING DISTRICT AND A
HOTEL/MOTEL OVERLAY DISTRICT 1 (HM0D1) ZONING DISTRICT BASED
UPON A REVIEW OF THE TOWN OF YARMOUTH ZONING MAP AND
PROPERTY CARDS.
4. THE PROPERTY LINES SHOWN HEREON, ARE COMPILED FROM
MASSACHUSETTS GEOGRAPHIC INFORMATION SYSTEM AND ARE BASED
UPON THE NORTH AMERICAN DATUM OF 1983 (NAD83) AND ARE NOT
BASED UPON A BOUNDARY SURVEY BY ATLANTIC DESIGN ENGINEERS, INC.
5. THE PROPERTY LIES WITHIN FLOOD ZONE X, AN AREA OF MINIMAL
FLOODING, BASED UPON A REVIEW OF THE FEDERAL EMERGENCY
MANAGEMENT AGENCY (FEMA) FLOOD INSURANCE RATE MAP (FIRM) MAP
NUMBER 25001CO587J, EFFECTIVE DATE JULY 16, 2015.
6. THE LOCUS LIES WITHIN A ZONE II BASED UPON REVIEW OF THE
MASSACHUSETTS GEOGRAPHIC INFORMATION SYSTEM AND THE TOWN OF
YARMOUTH GEOGRAPHIC INFORMATION SYSTEM.
7. THE LOCUS LIES WITHIN THE GROUNDWATER PROTECTION OVERLAY
DISTRICT BASED UPON REVIEW OF THE TOWN OF YARMOUTH GEOGRAPHIC
INFORMATIONSYSTEM.
8. THE SITE IS NOT LOCATED WITHIN AN ESTIMATED HABITAT OF RARE
WILDLIFE OR A PRIORITY HABITAT OF RARE SPECIES BASED UPON A
I REVIEW OF THE NATURAL HERITAGE AND ENDANGERED SPECIES PROGRAM
MAPS OBSERVED ON THE MASSACHUSETTS GEOGRAPHIC INFORMATION
1 SYSTEM.
i
19. THE PROPERTY DOES NOT LIE WITHIN AN AREA OF CRITICAL
ENVIRONMENTAL CONCERN (ACEC) BASED UPON A REVIEW OF THE
MASSACHUSETTS GEOGRAPHIC INFORMATION SYSTEM.
10. THE EXISTING CONDITIONS SHOWN HEREON ARE BASED UPON A FIELD
SURVEY BY ATLANTIC DESIGN ENGINEERS, INC. IN AUGUST OF 2024 AND
SUPPLEMENTED BY INFORMATION OBTAINED BY THE MASSACHUSETTS
GEOGRAPHIC INFORMATION SYSTEM, THE TOWN OF YARMOUTH
GEOGRAPHIC INFORMATION SYSTEM, AND INFORMATION OBTAINED FROM
PUBLIC RECORDS.
DESIGN FORMULA:
NO GARBAGE GRINDER ALLOWED WITH THIS DESIGN
SYSTEM
REQUIRED
PROVIDED
DAILY FLOW:
3,000 SF RETAIL ® 50 GPD/1000 SF
150 GPD
200 GPD (MIN)
LEACHING AREA:
(2) LEACHING CHAMBERS W/2' STONE
8.83' VIDE - 21' LONG
2' EFFECTIVE DEPTH
SIDEWALL: (8.83'+8.83'+21.0'+21.0') X 2'
119.32 SF
BOTTOM: (8.83' X 21.0')
185.43 SF
304.75 SF
TOTAL:
LEACHING CAPACITY:
BOTTOM: 304.75 SF x 0.74 GPD/SF
TOTAL:
200 GPD
228.6 GAL
A) -Jul- d I,/
Yarmouth Health Department
OVED
----- �.
Name Date
WIGGIN MEANS PRECAST NOTE:
(2) 500-GALLON LEACHING CHAMBERS H2O THE FINISH GRADE ABOVE THE SOIL
OR APPROVED EQUAL ABSORPTION SYSTEM SHALL HAVE A
PROVIDE RISER -SOIL ABSORPTION SYSTEM- MINIMUM SLOPE OF 2% TO REDUCE
AND COVER TO INFILTRATION AND TO MINIMIZE EROSION
WITHIN 6" OF PROVIDE RISER AND
FINAL GRADE
PRO`/IDE S" OF J" TO COVER TO FINISHED
F.G.=22.10't WASIiED STONE (TYP) GRADE
6" SUMP
MIN.
dim
4" PVC
2% (TYP)
EX.
19.57' 19.4
ELEV. ELEV.
7.0'f
PROVIDE LEVEL 6" -
COMPACTED CRUSHED
STONE BENEATH
DISTRIBUTION BOX
4" PVC
2% (TYP)
15't
TO CHAMBER INLET
5'
(MIN)
L-.
OF 1 1 DOUBLE
3'
MAX. COVER
/-IRO'ADE
WASHED STOyN,E (TYP)
9"
MIN. COVER
I'
a
177
INV. INTO CHAMBERS
BOTTOM
OF SYSTEM
,I F\/ =1 R as
I V =1 R QR
APPLICANT:
R.J. BEVILACQUA CONSTRUCTION CORP.
152 KIAHS WAY
DATE REVISION SANDWICH, MA 02563
8.83'x21'x2'
PROPO ED OVERDIG
(IF REQ IRED) - OVERDIG UNTIL
C LAYER IS ENCOUNTERED
F.G.=22.30't
TOP OF SYSTEM
ELEV.=20.04
EFFECTIVE
PROPOSED 4" SOLID
SCH. 40 PVC
VENT W/ BUG SCREEN
COORDINATE LOCATION
WITH OWNER
F.G.=23.50'f
5' MINIMUM
SEPARATION TO
J
GROUNDWATER
5
(MIN)
GW < 10.50
(NO GROUNDWATER
ENCOUNTERED IN TEST PITS)
SEPTIC REPAIR PLAN
FOR
1301 ROUTE 28
SOUTH YARMOUTH, MA 02664
OCTOBER 10, 2024
FILE: 3391-SEPTIC
Sheet of
1 1
JOB NUMBER
3391.00