Loading...
HomeMy WebLinkAboutBHDC-24-50LEGEND X 99.1 EXIST. SPOT ELEV. -[991- PROPOSED CONTOUR 198.41 PROPOSED SPOT EL. TH1 TEST HOLE ZYYY%f� SLOPE OF GROUND UTILITY POLE 'lY FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING � � � C /6,'�D7� ' �3,5 �S w PAVED �a w DRIVEWAY o ter° Q w G Q7h' ,D . 2 DICE #24- 018 1 31 SYSTEM PROFILE ALL SYSTEM COMPONENTS SHALL BE NOTES MARKED WITH MAGNETIC TAPE OR PROVIDE MIN. 20" DIAM. WATERTIGHT (NOT TO SCALE) COMPARABLE: MEANS FOR FUTURE LOCATION. 1. DATUM IS NAVD 88 ACCESS COVERS TO WITHIN 6" OF FIN. GRADE 2" PEASTONE OR GEOTEXTILEF2% CONCRETE COVERS TO WITHIN 3" GRADE TOP FOUND. EL. 32.3' 2. MUNICIPAL WATER IS EXISTING FILTER FABRIC OVER STONE MINIMUM .75' OF COVERT SLOPE REQUIRED OVER SYSTEM 34.0' J/ 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. PRECAST H-10 MIN. 2' WALL THICKNESS " - MIN. 2 WALL THICKNESS 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS RISERS (TYP.) PRECAST H-10 BLOCKS OR TO BE AASHO H-]Q 2'0 ' MRISERS (TYP.) OUTLETS TO PRECAST RISERS 35.3 DBOX #3 & #4 4"4SCH40 PVC 4"�SCH40 PVC MORTAR ALL H-10 PIPES LEVEL 1ST 2' PIPES LEVEL 1ST 2' 4. COMPONENTS 5. PIPE JOINTS TO BE MADE WATERTIGHT. • (TYP.) T ENDS SIDES 6. 18" EXISTING 24" PROPOSED ,.. 31.0' CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH y 310 CMR 15.000 (TITLE TEE 2500 GAL TEE 33.8t' i0 14" �<o�.a�.a� .•.•<<.•.•<•,< * 1500 GAL H-10 ° o ° ° r ** 33.79 TEE TEE , - ®®® )00000000q TLE 5.) SEPTIC TANK - SEPTIC TANK 3.54 °°°<,°°°°°°° ° p o 0000°° ®®®p®®®� ®® °°°°°°°° 7. THIS PLAN IS FO GAS BAFFLE ::' GAS BAFFLE °°°�°n°o°o°° 30.42 °°°o°o°o°a°o o°o°o°o° NPORNM R PROPOSED WORK ONLY AND NOT TO �_O O O ° O_ ..On On0.0„O_ >0000000. ,°°000000 ®®�®®®®®®Ll LIQ. LEVEL (ACME OR EQUAL) ," 33.53' 33.36' ' 00000000 ®® ®®®®®®® ® ;0000000o BE USED FOR LOT LINE STAKING OR ANY OTHER 30.25 ° ° ° ° 28 17' PURPOSE. °°°°°°°° °Oo�oJQ0000000000000000°0°0000000°0°0°000°000°000•' B" MIN. SUMP ".-MIN. SUMP $. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. °,?°°n�°o9°°O°°°°o0°0°0°o°�°non°�.°,o°n9.°�90°0°° 12" MIN. INT. DIM. 12" MIN. INT. DIM. H-10 500 GAL. LEACHING CHAMBER BY ACME PRECAST OR EQUAL. "INSTALLER SHALL CONFIRM MINIMUM SEPTIC TANK SIZE AT 4 L DIOUTSIDE OF STONE: 33X 12.833/4"-1-1/2" DOUBLE WASHED STONE (3) UNITS REQUIRED 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED L 6" CRUSHED STONE OR MECHANICAL OVERALL TO ' ' WITHOUT INSPECTION BY BOARD OF HEALTH AND WITH 3000 GALLON H-20 IF NOT SUITABLE GALLONS AND ITS SUITABILITY FOR RE -USE. REPLACE COMPACTION. (15.221 [2)) ^ PERMISSION OBTAINED FROM BOARD OF HEALTH. WITH � 1 ( % SLOPE) ( 1 _ X SLOPE) ( SLOPE) (1 %SLOPE) 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING FOUNDATION EXIST. SEPTIC TANK #1 1' SEPTIC TANK #2 1 ' D BOX #1- D LEACHING DIGSAFE (811) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO LOCUS MAP 85 BOX #2 10 FACILITY COMMENCEMENT OF WORK. *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL �- GpC__> 4 ���-��•.�.r� 23.0' BOTTOM TH-2 NO GROUNDWATER FOUND SCALE 1 =2000' t 11• ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM _ j YV�% � N 10 ) REMOVED BENEATH AND 5' AROUND THE PROPOSED LEACHING FACILITY. ASSESSORS MAP 122 PARCEL 93 --�- SYSTEM DESIGN. 12. EXISTING LEACHING FACILITY SHALL REMAIN. SITE IS NOT LOCATED IN MASSDEP NITROGEN GARBAGE DISPOSER IS NOT ALLOWED 13. WETLAND FLAGGED BY BRAD HALL OF BLH SENSITIVE AREA (NSA) ENVIRONMENTAL CONSULTING 1-31-24. EXISTING 9 BEDROOM INN PROPOSED 3 BEDROOM EXPANSION 14. MATCH ALL EXISTING GRADES INTO EXISTING LEACHING FIELDS. INSTALLER TO CONFIRM INVERT ELEVATIONS PRIOR DESIGN FLOW: 12 BEDROOMS ® 110 GPD = 1320 GPD TO INSTALLING ANY PORTION OF THE SEPTIC SYSTEM EXPANSION. PAVED (} d SEPTIC TANK: 1320 GPD (2) = 2640 DRIVEWAY 1320 GPD (1) = 1320 0 o 1236 + 618 = 3960 GAL. REQUIRED Q USE EXISTING 2500 GAL. SEPTIC TANK & ADD A 1500 GAL. SEPTIC TANK IN SERIES (4000 GAL. TOTAL) EXISTING 9-BEDROOM LEACHING FIELD TO REMAIN LEACHING EXPANSION DESIGN FLOW: TEST HOLE LOGS 0 3 BEDROOMS ® 110 GPD = 330 GPD 3� LEACHING: ENGINEER: DANIEL E. GONSALVES, SE #13587 �R \ SIDES: 2 (33.5 + 12.8) 2 (.74) = 137 GPD WITNESS: BARRY LEWIS BOTTOM 33.5 x 12.8 (.74) = 317 GPD DATE.. / 16 2 2024 / ti TOTAL: 614 S.F. 454 GPD PERC. RATE _ < 2 MIN INCH ./\-''30 . _ all, USE (3) 500 GAL. LEACHING CHAMBERS -(ACME OR EQUAL) WITH 4' STONF Al i ARnI INn CLASS I SOILS PAVED DRIVEWAY�-,,� � 3 � a SR9• / a EXISTING / BUILDING J / p r RR&P0SED 34 r7 ; BOX 4 (SEE NOTE 4) 0 BENCHMARK SPIKE SET "PAVED \c \ DRIVEWAY G G 3 3s #1 � D � v 0 TOF = 38.0' x Q Q EXISTING ` _ DWELLING Ns8233g Q b 3137 k \ \\ S / 0 100• OFF ` �RESERVE p WET ` WORK LIMIT LINE SILT \ \ ,/Q �� •�. \ FENCE \ / 50, FF •�..__._. ...�ETLq D•_. Q d �s BORDERING VEG •RING`• .� ATED W ETLA 1101, VENT �. 32 'OVED F'A „ n ELEV. n ELEV. V' MA 0 35.0 0,, 34.0' DATE BOARD OF HEALTH F77A �SL A SL 4" 10YR 3/2 10YR 3/2 VK11 /B 12„ Z 24" 10YR�5/4` 33.0' SL 1OYR 5/4 G 36" 31.0' BLS Io I)epartm' �t 60" UNSUITABLE SOIL 1OYR 7 /4 30.0 �ED C2 C1 Date �FLS M /CS 96" 2.5Y 5/3 27.0' 2.5Y 7/4 C3 VFS 2.5Y 7/2 144 23.0 ' " 1 �2� 23.0' NO GROUNDWATER ENCOUNTERED ` 02� OfSTE£i . i � E DATE DANIEL A. OJALA, P.E., P.L.S. TITLE 5 SITE PLAN of 4 SUMMER STREET YARMOUTHPORT, MA PREPARED FOR INN AT CAPE COD DATE: MARCH 8, 2024 Scale: 1 "= 20' G�;iG�%1L7 2024 0 10 20 30 40 50 FEET HEALTH DEFT. off 508-362-4541 fax 508-362-9880 downcape.com down cope engineering, Inc. civil engineers land surveyors 939 Main Street ( Rte 6A) SURVEY: NHO YARMOUTHPORT MA 02675 DRAFTED BY: DEG CHECKED BY: Y) , 1 24-018 INN AT CAPE COD.DWG