Loading...
HomeMy WebLinkAboutBHDC-24-151LEGEND --- 99 - EXISTING CONTOUR X 99• 1 EXIST. SPOT ELEV. -[99]-- PROPOSED CONTOUR 198.41 PROPOSED SPOT EL. TH1 Y TEST HOLE 2%, SLOPE OF GROUND C-OL.) UTILITY POLE FIRE HYDRANT NOTE; NOT ALL. SYMBOLS MAY APPEAR IN DRAWING �o I SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED EXISTING 6 BEDROOM DWELLING DESIGN FLOW: 6 BEDROOMS ® 110 GPD = 660 GPD USE A 660 GPD DESIGN FLOW SEPTIC TANK: 660 GPD (2) = 1320 USE EXISTING 2,500 GAL. DUAL COMPARTMENT SEPTIC TANK LEACHING: SIDES: 2 (50.5 + 12.83) 2 (.74) = 188 GPD BOTTOM 50.5 x 12.83 (.74) = 479 GPD TOTAL: 901 S.F. 667 GPD USE (5) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE AL AROUND APPROVED Dd od �4� �rO MA DATE BOARD OF HEALTH �t s n� �25 LOT AREA: Op 20,000 S.F. 0.46 i AC. EXISrING LEACHI G r #1 TO BE ABANDONED INV. IN *15.39' ., ZABEL FILTER OUTLET TEE W/EXTENSION ;'YSTEM PROFILE (NOT TO SCALE) ACCESS COVERS TO WITHIN 6' OF FIN. GRADE 2" PEASTONE OR GEOTEXTILE 19.8' FILTER FABRIC OVER STONE 19.5' ��. ►- 1000 1500 GAL. COMPARTMENT / I I/ � , WATERTEST D'BCX FOR LEVELNESS 2' PRESSURE LINE 4"0SCH40 PVC pRpp PIPES LEVEL 1ST 2' 4'- SLOPE TO DRAIN BACK TEE: ENDS EXISTING 2500 GAL. SEPTIC TANK/ PUMP CHAMBER COMBINATION *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND PUMP CHAMBER ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. - CONCRETE COVERS TO WITHIN 3' GRADE 2% SLOPE REQUIRED OVER SYSTEM 20.0 BLOCKS OR PRECAST RISERS MORTAR ALL INVERT IN 17.67' COMPONENTS 4' (�'•) �SDES 18.5' �`.. 00.' Op O(.00000 �po0000000� OOgO�'OOOOO O '00000000 ® ;0000000 ® j1' ®®® GJ :O�OOOOOO 0 0 0 0 11.74' °o 0 0°0 f 0�0�� 15.67 6" MIN. SUMP 12" MIN. INT, DIM. H-10 500 GAL. LEACHING CHAMBERS BY ACME PRECAST OR EQUAL 3/4"-1-1/2" DOUBLE WASHED STONE 4' MIN. (5) UNITS REQUIRED ALL AROUND PRECAST STRUCTURES 6' CRUSHED STONE OR MECRkNICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 50.50' X 12.83' COMPACTION. (15.221 [21) (1 X SLOPE) - 21' D' 30X 24' LEACHING TH-1 FACILITY GROUNDWATER FOUND AT EL. 10.5' 0.00' ADJ. VARIANCES REQUESTED: UNDER MAX. FEASIBLE COMPLIANCE 15.405: (1 a): REDUCTION IN SETBACK, SAS TO LOT LINE (10' TO 5.0') (1 b): REDUCTION IN SETBACK, SAS TO FOUNDATION (20' TO 10.8') 0) yFOGE V l PAVED G, DRIVEAt W` 00' All x / g j � NG C , �✓ l y � t of , 79.8' EX. SEPTIC Pq/i TANK TO / REMAIN / PROVIDE; 63' OF 40 MIL LINER AT 5' Or SAS IN AREA o° SHOWN. OP AT ELEV. 20.0', ,p BOTTOM AT EL. 15.0'f 79 ' 5' REMOVAL OF UNSUITABLE SOIL 7- �' TP ✓' �\ it �� REQUIRED AROUND PERIMETER OF ?g 0 ~ LEACHIfi1G FACILITY, DOWN TO SUITAB,LE SOIL LAYER. REPLACE BENCHMARK: WITH CLEAN MED. SAND, TO MEET BULKHEAD �� ' ; Nib SP CICATIONS OF 310 CMR = 19.4' NAVD88 �� ����,, r 1 5X3) o i EXISTING LE CHING #2 TO BE(REMOVED OFFICE t LIVING I KITCHEN ROOM BED ROOM BATH ROOM BATH DINING ROOM ROOM BED ROOM 1 ST FLOOR LIVING ROOM KITCHEN BED BATH ROOM ROOM BED ROOM LIVING BED ROOM ROOM 2ND FLOOR FLOOR PLAN NOT TO SCALE BATH ROOM BED ROOM 2ND FLOOR IN-LAW NOTES 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1 /8' PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-LQ 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACQORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (811) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED BENEATH AND 5' AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED LEACHING #2. 13. OWNER'S ENGINEER TO PERFORM INSPECTIONS OF THE FINAL INSTALLATION. MINIMUM OF 24 HOURS NOTICE REQUIRED. 14. EXISTING 2,500 GAL. DUAL COMPARTMENT SEPTIC TANK & PUMP TO REMAIN. 15. OWNER'S ENGINEER TO INSPECT PUMP & ALARM PRIOR TO BACKFILL OF PROPOSED LEACHING FIELD. TEST HOLE LOGS SOIL EVALUATOR: JOHN DOYLE DATE: 12/4/01 PERC. RATE _ < 2 MIN/INCH CLASS __ _ SOILS r C� ELEV. 0„ "V 19.5' 0/A/E LS / ' 1OYR 6/6 34" ///// 16.7' MS 89" 2.5Y 8/4 12.1 ' C2 SiCL 101" 5Y 7/3 C3 CS OYR 8/6 124" I I 9.2' GROUNDWATER ENCOUNTERED AT 123" EL. 9.3' Yarmouth Health p Ut O 1\am Date DATE DANIEL A. OJALA, P.E., P.L.S. LOCUS MAP SCALE 1 "=2000'f ASSESSORS MAP 141 PARCEL 32 LOCUS IS WITHIN FEMA FLOOD ZONE X (AREA OF MINIMAL FLOOD HAZARD) AS SHOWN ON COMMUNITY PANEL #25001CO578J DATED 7/16/2014 SITE IS NOT WITHIN STATE DESIGNATED NSA TEST HOLE LOGS ENGINEER: CRAIG J. FERRARI, SE # 13871 WITNESS: BARRY LEWIS DATE: 5/16/24 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS Q ELEV. 1 0" 19.0' A LS 10YR 3/2 24" ' B LS 10YR 5/8 60 //// 14' PERC C, FS 2.5Y 7/4 132" 8' GROUNDWATER ENCOUNTERED AT 102" EL. 10.5 OF UNSUITABLE SOIL G-W ADJ. DATA: WELL: SDW-252R ZONE: A ADJ: 0.00' APRIL 2024 1 i / I HOMERS DOCK ROAD YARMOUTH PORT, MA PREPARED WANITA CAHILL DATE: J U N E 5, 2024 Scale:1 "= 20' .5 10 20 30 40 50 -ET off 508-362-4541 I fax 508-362-9880 downcape.com down cape engineering, I'M. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02575 K=IVjrIDI Aug 11 2(124 HEgLTH DEPT SURVEY: QAH DRAFTED BY: CJF/PTT CHECKED BY: 24-107 CAHILL.DWG DICE #24-- 10