HomeMy WebLinkAboutBHDC-24-62T.O.F. EL.= 127± #4 PROPOSED EXTENSION RISER 12.3'± #6 WITH COVER OVER INLET & OUTLET TO WITHIN 6" OF F.G. FINISH GRADE @ FND. EL.= VARIES F.G. OVER TANK EL. = 1 1.3'± -EXISTING 4' PROPOSED 4" SEWER PIPE �_. SCH. 40 PVC SEWER PIPE -- �� 3" DROP MAX 2" DROP MIN 3„ 9 7SLOPE-- 13" 14" ►NTRACTOR TO PROVIDEECIFIED DROP BETWEEN .ET AND OUTLET CONTRACTOR CONTRACTOR SHALLSHALL VERIFY SIZE 48" VERIFY CONDITION OF AND CONDITION OF EXISTING TEES GAS BAFFLE EXISTING SEPTIC AND REPLACE AS TANK NECESSARY t� a, �l L_ EXISTING 1,000 GALLON CONCRETE SEPTIC TANK _rRIFY EXISTING ) ANY WORK & I?TrFRFNT 43.Y- NOT TO SCALE MAP 33 LOT 61 N�2o OZ 00„E 100 �0 - #8 EXISTING •1-BEDR00 l / C OTTAQ #10 EXISTING 2-BEDROOM COTTAGE (CRAWL) HC-3� ' k 24.3'--" 2) 1 O 0 c o o� Q S00° 43' 10"W 14.00' MAP 33 LOT 62 10,273± S.F. #6 EXISTING 2-SEPROOM -COTTAGE (CRAWL) MAP 33 LOT 67 0 00 0 0 0 00 ni LTOF=12.3'±� 1 HC-1 45 6g - 00^V� #4 TOF=127± S,IZo 02 0�--EXISTING 2}BEDROOM �\ COTTAGE (CRAWL) o MAP 33 o LOT 63 S890 16' 50"E = =- o W 51.49' EASEMENT PER �N00° 43' 10"E P.B. 588, PG. 44 14.00' _ S890 16' 50"E _ 37.00' SWING -TIES & DIMENSIONS SCALE: 1" = 20' NOTES: 1. MAGNETIC MARKING TAPE SHALL BE PLACED ALONG THE TOP EDGE OF EACH SEPTIC SYSTEM COMPONENT. 2. CONTRACTOR SHALL VERIFY SOIL CONDITIONS IN THE LOCATION OF THE PROPOSED LEACHING FACILITY TO ENSURE CONSISTENCY WITH TEST PIT DATA SHOWN ON THIS PLAN. REPORT TO ENGINEER AND LOCAL BOARD OF HEALTH IF SOILS ARE NOT CONSISTENT WITH TEST PIT DATA. 3. ENTIRE PROPERTY IS NOT LOCATED WITHIN A MASS DEP ZONE II. 4. SWING TIES SHOWN ON THIS PLAN ARE PROVIDED ONLY AS A COURTESY FOR THE INSTALLER. INSTALLER SHALL VERIFY SWING TIE MEASUREMENTS IN THE FIELD PRIOR TO INSTALLING THE SYSTEM. CONTRACTOR SHALL NOTIFY ENGINEER IF MEASUREMENTS APPEAR TO BE INCORRECT IN THE FIELD. 5. LOCATION OF EXISTING WATER ScRVICE LINES SHOWN ON THIS PLAN ARE APPROXIMATE ONLY AND IS BASCD ON A PLAN ENTITLED, "PROPOSED SEWAGE DISPOSAL SYSTEM REPAIR", DAT_D JANUARY 11, 2002, PREPARED BY SCHOFIELD BROTHERS OF CAPE SOD, ON FILE WITH THE YARMOUTH HEALTH DEPARTMENT. IN SHOWN ON THIS PLAN WAS SURVEYED 6. LOCATION OF EXISTING WATER N -HE YARMOUTH WATER DEPARTMENT. NU 0 W�A Vk QQT V MAP 33 LOT 66 MAP 33 LOT 64-1 FINISH GRADE OVER D-BOX = 1 1.1'± H-20 REMOVABLE WATER -TIGHT COVER OVER H-20 RISER TO WITHIN 6" OF FINISHED GRADE I t-5" DIA. OUTLET(S) 9" MIN. 36" MAX. L=38'± I PROVIDE WATERTIGHT 4" PVC IN FROM JOINTS (TYP.) SEPTIC TANK 4" PVC OUT TO LEACHING FACILITY 12" 6"1 \_ 8.3&,, 8.47' MIN. 6" CRUSHED STONE o OVER MECHANICALLY COMPACTED BASE 5 OUTLET DISTRIBUTION BOX TO BE INSTALLED ON A LEVEL STABLE BASE. FIRST TWO FEET OF OUTLET PIPES TO BE LAID LEVEL. CROSS SECTION VIEW (-H-20 DISsRISUTION SOX DETAIL SWING -TIES DESCRIPTION HC-1 HC-2 HC-3 CORNER OF STONE (1) 18.0' 25.1' 45.4' CORNER OF STONE (2) 26.3' 22.0' 37.4' CORNER OF STONE (3) 33. 1' 47.1' 15.8' CORNER OF STONE (4) 37.9' 57.9' 16.9' CORNER OF STONE (5) 24 1' 58.6' 36.2' FINISH GRADE OVER CHAMBERS = 10.4' - 11.3' PROP. VENT WITH CHARCOAL FILTER TO ABOVE GRADE GENERAL NOTES SLOPE @ 2% MIN. OVER SYSTEM 3/4" TO 1_-1/2" DOUBLE WASHED 1. UNLESS OTHERWISE NOTED, ALL SYSTEM COMPONENTS AND CONSTRUCTION CRAWL FLOOR EL.= 10.8'± #4 STONE TO-C-ROWN-OF PIPE --- - METHODS SHALL BE IN ACCORDANCE WITH TITLE 5 OF THE STATE ENVIRONMENTAL 4" SCHEDULE 40 PVC CRAWL FLOOR EL.= 1 1.4'± #6 2" OF 1/8" TO 1/2" DOUBLE WASHED CODE AND ANY APPLICABLE LOCAL RULES. MIN SLOPE 1 /o STONE OR GEOTEXTILE FILTER FABRIC 2. ANY CHANGES TO THIS PLAN MUST BE APPROVED BY THE BOARD OF HEALTH AND THE CRAWL FLOOR EL.= 10.7'± (#10) DESIGN ENGINEER, TOP OF SAS = 8.93' PLACE H-20 RISER ON 3. 4" SCHEDULE 40 PVC PIPE WITH WATER TIGHT JOINTS SHALL BE USED IN DISPOSAL 9" MIN. ALL CHAMBERS w/ SYSTEM UNLESS OTHERWISE NOTED. 8.1 O 36" MAX. BREAKOUT EL = $.60' PIPED INLETS TO 4. TO PREVENT BREAKOUT, THE PROPOSED FINISHED GRADE SHALL NOT BE LESS THAN WITHIN 6 OF F.G.­".' ELEVATION = 8.60' FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE SAS. UNLESS A 40 MIL GEOMEMBRANE LINER IS PLACE AT LEAST FIVE FEET FROM S.A.S. AND THE TOP OF �o 0 O ��� ��p C: O THE LINER IS NOT LESS THAN THE BREAKOUT ELEVATION. 5. SLOPE ALL SOLID PIPE AT 1.0% MINIMUM. I00 0 0 0 CJ 0 0 (� o ��THIS SYSTEM IS NOT DESIGNED FOR A GARBAGE DISPOSAL. ' o 0 00 `T.-IOM BOARD OF HEALTH AND DESIGN ENGINEER TO BE NOTIFIED PRIOR TO BACK o0 oao o FILLING WHEN SYSTEM IS NEARLY COMPLETE AND READY FOR INSPECTION. SYSTEM IS o CD o0 0o C� o NOT TO BE BACK FILLED WITHOUT FIRST OBTAINING APPROVAL FROM BOARD OF HEALTH o AND DESIGN ENGINEER. _-4. 0'_ 6 08, ,TYP) ( 4,Q' I 8. ELEVATIONS BASED ON NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD 88). SEE d.0` 4.0' �, , 3.0' BENCHMARK LOCATION AND ELEVATION SHOWN ON PLAN. FLOOD ZONE LINE DIVIDING ZONE X (<500) FROM ZONE AE (EL.11) BASED ON ACTUAL ON -THE -GROUND FIELD INSTRUMENT SURVEY (B.F.E. = 11.O' NAVD 88 BASED ON F.I.R.M. #25001C0589J) (EFFECTIVE JULY 16, 2014) IST GALLON SEPTIC i TANK TO R .0-10 - 12- EXISTING J' 1-BEDROO C OTTAG #10 v cv GA o EXISTING 2-BEDROOM cn PROPOSED SIX (6) LC-6 COTTAGE ca9.» «�► LEACHING CHAMBERS w/ STONE 1 (CRAWL) f _ X11.4 O PROPOSED 4" SCH. 40 PVC VENT; X X ` ff, EXACT LOCATION PER OWNER a r BUSHES 24" REMOVE ALL UNSUITABLE 13" MATERIAL DOWN TO "C" SOIL & t,.. REPLACE w/ CLEAN COARSE ' -3 BUSH' �,.... % EXISTING 1 -,IL 2-BEDROOM SAND PER 310 CMR 255(5) U # lii1 D x11.5 COTTAGE ... - (CRAWL) x10.1 7.6' X 10.3 c f Cn G ! �� Gn. PROP. H-20 ` rn D-BOX =c� y z n II GRAVEL X 3. O 0 � DRIVEWk- #4 TP 1 EXISTING 2-BEDROOM t SATELLITE D i 10x1' COTTAGE DISH v < (CRAWL) mm a ! v C ' x10.3 G / \ 16, rn rn 1 2" / I CONC. I� nj D) / x 9 .. / EASEMENT PER Z / P.B. 588, PG. 44 7.10' SITE PLAN scXE. V = 2u VARIES (SEE PLAN) (�'P�) GROUND WATER ELEV.= 3. 10' (mottling_ 9. CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS PRIOR TO CONSTRUCTION 11.0' THROUGH DIG -SAFE AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE AT 5.0' MIN. REQ'D 1-888-DIG-SAFE AND ANY OTHER APPLICABLE AGENCIES. REPORT ANY DISCREPANCIES , LC-6 CHAMBERS 4.0 PROP. (See Gen. Note #22) CHAMBE' � END VIEV1, TO THE DESIGN ENGINEER. TYPICAL CHAMBER PROFILE CI-IAM0 '-r--_' r_` #.---TAI L;_ 10. ALL JOINTS WHERE PIPE ENTERS AND EXITS CONC. STRUCTURES SHALL BE MADE WATERTIGHT. NOT TO SCALE 11. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING REGULATIONS. OWNER/APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM �+"" APPROPRIATE AUTHORITY. ,rry ��f �.-�,�-�'� �'ET �' DA I 12. ALL SEPTIC SYSTEM COMPONENTS SHALL WITHSTAND H-10 LORDING UNLESS LOCATED INSPECTOR: Barry Lewis BOH) UNDER MORE THAN 3 FEET OF COVER OR LOCATED UNDER PAVEMENT, DRIVES, OR ' r:• �` ''� i EVALUATOR: Michael Pimentel, EIT, CSE TRAVELED WAYS IN WHICH CASE THEY SHALL WITHSTAND H-20 LOADING. I� �`� �• b C.S.E. APPROVAL DATE: Oct. 27, 1999 13. DOUBLE WASHED CRUSHED STONE SHALL BE FREE OF ALL DIRT, DUST AND FINES. ~ �I • ` DATE: March 14, 2024 14. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL LOAM, SUBSOIL AND UNSUITABLE • , Q�� , TEST PIT #: 1 MATERIAL IN AREA BENEATH AND FOR 5 FT. ON ALL SIDES OF LEACHING FACILITY. +•. • `. REPLACE ALL UNSUITABLE MATERIAL WITH CLEAN COARSE SAND FREE FROM CLAY •!1� _ , _ '; ELEV TOP = 1 C.10' FINES OR OTHER UNSUITABLE MATERIAL IN ACCORDANCE WITH 310 CMR 15.255 3 ELEV WATER = 3.10' 15. CONTRACTOR SHALL NOTIFY DESIGN ENGINEER OF ANY DISCREPANCIES FOUND IN SITE CONDITIONS FROM THOSE SHOWN PRIOR TO CONTINUATION OF WORK. PERC RATE _ < 2 min./inch 16. PROPOSED PROJECT IS LOCATED WITHIN: DEPTH OF PERC = 36" - 54" Q I ASSESSOR'S MAP 33 LOT 62 liy.,.t i I O - - „� TEXTURAL CLASS: I t! -" OWNER OF RECORD: SANDRA M. DIGIOVANNI, TRUSTEE (D o_ 05 co LO m a EXISTING 2-500 GALLON L CHING AMBERS w/ STON REMAIN XISTING SA3 TO B REMOVED & REPLAC�- WITH CLEAN SAND/ Benchmark Corner of Stoop Elev. = 12.34' N.A.V. D. 88 EXISTING 1.000 C SEPTIC TANK TO ,JTIUZED IN DESI LOCUS ADDRESS: PO BOX 1282 j 0" 10.10, SOUTH YARMOUTH, MA 02664 Fill 12' 9.10, FEMA FLOOD ZONE X (< 500) & AE (EL.11) COMMUNITY PANEL# 25001CO589JLOC 1 Loam Sand Y 17. DEED REFERENCE: BOOK 18696, PAGE 46 I I / B 10Yr 5/6 j F � ✓ 36 7.10 1& PLAN REFERENCE: P.B. 588, PG. 44 . tk . Perc 19, ALL DISTURBED AREAS SHALL BE RESTORED TO ORIGINAL CONDITION. 54" 20. PROPERTY LINE INFORMATION IS ONLY APPROXIMATE. THIS PLAN IS TO BE USED ONLY FOR SEPTIC SYSTEM UPGRADE. JC ENGINEERING WILL NOT ASSUME ANY LIABILITY �- C Medium 2.5Y 6/6nd FOR USES OF THIS PLAN OTHER THAN ITS INTENDED PURPOSE. 1 ` � 21. OWNER /APPLICANT /CONTRACTOR SHALL BE RESPONSIBLE TO OBTAIN ANY AND ALL L84" MottlingAa 84 - 3.10' REQUIRED PERMITS AND APPROVALS FOR THIS PROJECT. el Z I 4 O � I 961, /Standing @a 96" v 2 10' 22. IN ACCORDANCE WITH 310 CMR 15.401-15.405, THE FOLLOWING LOCAL UPGRADE APPROVAL IS REQUESTED FROM 310 CMR 15.212(1): " 1.) A 1.00' WAIVER (5.00' - 4.00') FOR THE SEPARATION BETWEEN THE SAS AND ESHGW. 23. IN ACCORDANCE WITH 310 CMR 15.401-15.405, THE FOLLOWING LOCAL UPGRADE PLAN APPROVAL IS REQUESTED FROM 310 CMR 15.211: 1.) A 24WAIVER (10.0' - 7.6) FOR SETBACK FROM PROP. SAS TO FRONT PROPERTY LINE. = 1000' 120" 0.10' 24. THE FOLLOWING VARIANCE IS REQUESTED FROM 310 CMR 15.223(1)(b): 1.) A VARIANCE FROM PROVIDING A 2nd TANK IN SERIES WITH A MIN. EFFECTIVE LIQUID CAPACITY OF 100% OF THE DESIGN FLOW OF 440 GPD (i.e. 100% x 440 gpd = 440 gallons). DESIGN DATA NUMBER OF BEDROOMS (#4 BLISCOTT)(EXISTING) 2 NUMBER OF BEDROOMS (#6 BLISCOTT)(EXISTING) 2 NUMBER OF BEDROOMS (TOTAL)(EXISTING) 4 �.. NUMBER OF BEDROOMS (DESIGN) 4 DESIGN FLOW 110 GAUDAY/BEDROOM TOTAL DESIGN FLOW 440 GAUDAY DESIGN FLOW x 200 = 880 GAUDAY USE EXISTING 1,000 GALLON SEPTIC TANK (SEE GENERAL NOTE 24 FOR VARIANCE REQUEST FOR 2nd TANK) INSTALL (6) LC-6 LEACHING CHAMBERS w/ STONE SIDEWALL CAPACITY (TOTAL PERIMETER) (1- HIGH) (0.74 GPD/S.F.) = GAUDAY (111.0') (l') (0.74 GPD/ S.F.) = 82.1 GAUDAY BOTTOM CAPACITY (FOOTPRINT AREA) (0.74 GPD/S.F.) = GAL/DAY (489 S.F.) (0.74 GPD/S.F.) = 361.9 GAUDAY TOTALS: TOTAL NUMBER OF CHAMBERS 6 TOTAL LEACHING AREA 600.0 SQ.FT. TOTAL LEACHING CAPACITY 444.0 GAL./DAY RESERVED FOR BOARD OF HEALTH USE 50xO' - 50 - -- 50 50 vAS O/H /W .. -W W LSA Yarmouth H hDepurtmmt t�' Q Y ED 0 REV. I DATE OF MqS�� tiG JOHN L. CHURCHILL JR. a a CIVIL Q NO. 48066 ti ,H OF Mq f� gcyG JOHN L CHURCHILL JR. CIVIL NO. 41807 EXISTING SPOT GRADE EXISTING CONTOUR PROPOSED CONTOUR PROPOSED SPOT GRADE EXISTING GAS LINE EXISTING OVER HEAD WIRES EXISTING WATER LINE EXISTING LANDSCAPED AREA TEST PIT LOCATION EXISTING 1,000 GALLON SEPTIC TANK PROPOSED 4" SOLID SCHEDULE 40 PVC PIPE PROPOSED H-20 DISTRIBUTION BOX PROPOSED LC-6 CONCRETE LEACHING CHAMBER BY APP'D. I DESCRIPTION PROPOSED SEPTIC SYSTEM UPGRADE PREPARED FOR i ROBERT B. OUR CO., INC. LOCATED AT 4 & 6 BLISCOTT AVENUE SOUTH YARMOUTH, MA 02664 SCALE: 1 INCH = 20 FT. DATE: APRIL 5, 2024 0 10 20 40 80 FEET PREPARED BY JC ENGINEERING, INC. 2854 CRANBERRY HIGHWAY EAST WAREHAM, MA 02538 508.273.0377 Drawn By: MCP Designed By: MCP Checked By: JLC JOB No. 7593