Loading...
HomeMy WebLinkAboutBHDC-24-33T.O.F. EL.= 20.9'± PROPOSED EXTENSION RISER WITH COVER OVER INLET & FINISH GRADE OUTLET TO WITHIN 6" OF F.G. @ FND. EL.= 19.8'± F.G. OVER TANK EL. = 19.5'± EXISTING .:- PROPOSED 4" f �EL1+En r►t�E �"" SCH, 40 PVC - �„�� SEWER PIPE t.vty 4 KAii i Uf% i U VLKW -f LXISTING ELEVATION PRIOR TO ANY WORK & •trtrEcv c#[r-rutcco tc rucccocmr rL0 HC-1� T�l�,, f #4 DE, EXISTING 2-BEDROOM DWELLING TOF=20.9'± r 6" 3" 3 DROP MAX 2" DROP MIN 3„ 9„ SLOPE 1 13" 14" - *17.5'± CONTRACTOR CONTRACTOR SHALL SHALL VERIFY SIZE 48" VERIFY CONDITION OF \ OUTLET TEE AND CONDITION OF EXISTING TEES S BAFFLE EXISTING SEPTIC AND REPLACE AS TANK NECESSARY"����� j EXISTING 1,000 GALLON CONCRETE SEPTIC TANK SEP-T'o -r-A1"W PROFILE NOT TO SCALE SWING -TIES & DIMS. SCALE: 1" = 20' SWING -TIES DESCRIPTION HCA HC-2 DC CORNER OF STONE (1) 20.4' 68.6' 24.3' CORNER OF STONE (2) 32.1' 79.4' 35.0' CORNER OF STONE (3) 42.6' 73.5' 34.4' CORNER OF STONE (4) 34.6' 61.7' 23.6' NOTES: 1. MAGNETIC MARKING TAPE SHALL BE PLACED ALONG THE TOP EDGE OF EACH SEPTIC SYSTEM COMPONENT. 2. CONTRACTOR SHALL VERIFY SOIL CONDITIONS IN THE LOCATION OF THE PROPOSED LEACHING FACII JTY TO ENSURE CONSISTENCY WITH TEST PIT DATA SHOWN ON THIS PLA' I REPORT TO ENGINEER AND LOCAL BOARD OF HEALTH IF SOILS ARE NOT "ONSISTENT WITH TEST PIT DATA. 3. ENTIRE PROPERTY IS LOC: ' ED WITHIN A MASS DEP ZONE 11. 4. SWING TIES SHOWN ON TF' 3 PLAN ARE PROVIDED ONLY AS A COURTESY FOR THE INSTALLER. INST., LLER SHALL VERIFY SWING TIE MEASUREMENTS IN THE FIELD PRIOR TO INS ; ALLING THE SYSTEM. CONTRACTOR SHALL IREMENTS APPEAR TO BE INCORRECT. NOTIFY ENGINEER IF MEAL FINISH GRADE OVER D-BOX = 18.1'± REMOVABLE WATER -TIGHT COVER OVER I ' RISER TO WITHIN 6" OF FINISHED GRADE 1-5" DIA. OUTLET(S) i 9" MIN. 36" MAX. L=40 ± 1-1 PROVIDE WATERTIGHT 4" PVC IN FROM JOINTS (TYP.) SEPTIC TANK 0_; 4" PVC OUT TO LEACHING FACILITY 14.80' IwiN.-14.63' 6" CRUSHED STONE OVER MECHANICALLY COMPACTED BASE 5 OUTLET DISTRIBUTION BOX TO BE INSTALLED ON A LEVEL STABLE BASE. FIRST TWO FEET OF OUTLET PIPES TO BE LAID LEVEL. CROSS SECTION VIEW �R� 20 DI ST : i.I ET. -i NOT TO SCALE FINISH GRADE OVER CHAMBERS = 18.2' - 17.0' SLOPE @ 2% MIN. OVER SYSTEM - 4" SCHEDULE 40 PVC MIN SLOPE 1% IM TOP OF SAS = 15.50' 9"IN. 14.50' 36" MAX. BREAKOUT EL = 15.00' 0 OD O 00 C 2 0 00 0 0 0 0 3.5' 8.5' (TYP) - 12.50' 3/4" TO 1-1/2" DOUBLE WASHED GENERAL NOTE STONE TO CROWN OF PIPE -� 1. UNLESS OTHERWISE NOTED, ALL SYSTEM COMPONENTS AND CONSTRUCTION 2" OF 1/8" TO 1/2" DOUBLE WASHED METHODS SHALL BE IN ACCORDANCE WITH TITLE 5 OF THE STATE ENVIRONMENTAL STONE OR GEOTEXTILE FILTER FABRIC CODE AND ANY APPLICABLE LOCAL RULES. - 2. ANY CHANGES TO THIS PLAN MUST BE APPROVED BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. PLACE RISER ON ALL 3. 4" SCHEDULE 40 PVC PIPE WITH WATER TIGHT JOINTS SHALL BE USED IN DISPOSAL CHAMBERS w/ PIPED INLETS SYSTEM UNLESS OTHERWISE NOTED. TO WITHIN 6" OF F.G. 4. TO PREVENT BREAKOUT, THE PROPOSED FINISHED GRADE SHALL NOT BE LESS THAN �o 0 ELEVATION = 15.00' FOR A DISTANCE OF 16 AROUND THE PERIMETER OF THE SAS. UNLESS A mow- 0 40 MIL GEOMEMBRANE LINER IS PLACE AT LEAST FfVE FEET FROM S.A.S. AND THE TOP OF LINER IS NOT LESS THAN THE BREAKOUT ELEVATION. o THE 0 5. _- SLOPE ALL SOLID PIPE AT 1.0% MINIMUM. THIS SYSTEM IS NOT DESIGNED FOR A GARBAGE DISPOSAL. C­77�LOCAL o o o o 0o 0 ao 0 0 00. oo BOARD OF HEALTH AND DESIGN ENGINEER TO BE NOTIFIED PRIOR TO BACK FOR INSPECTION. SYSTEM IS o 0 o FILLING WHEN SYSTEM IS NEARLY COMPLETE AND READY -rAINING APPROVAL FROM BOARD OF HEALTH «.� L GROUND WATER ELEV.= < 6.50' - 500 GALLON H-20 CHAMBERS' s MIN. TYPICAL CHAMBER PROFILE-0H.�, DETAILS NOT TO SCALE rn / �`45.36 d R,25.0 0 e a ti rs°' C� N 4 / I \ EX. TREE TO BE L9yO / \ REMOVED (TYP IN RED) �T O 4 w � T3. o X. TREE TO BE SAVED � coVv \ (TYP IN GREEN) `�Zd�ev \ \ \ 16 / 17- \ \ e PROPOSED TWO (2) 500 \' l / 2" 8" GALLON H-20 LEACHING �rO „ 12" r' \ CHAMBERS w/ STONE 10 \12 -18,16�'- 12" I 1'' 12"--� `T 1 I f TREELINE \ \ \ ,6 \ - I 12 \ -19-- 7 h BIT. DRIVEWAY O j i N. / 4 _ �l (4)12„ I / - _- U) \ \ 0 0 / �_ DECK C / EXISTING \ w w 2-BEDROOM _ DWELLING x 0 2 ( rn� f / zI ! o , MAP 45 I TOF=20.9'+ m m Cn \ LOT 7 y (n 18,797± S.F. Co O � 1 20 // LP �` C6 � "' l z 1 f g < / 1r O 1 / ri 1 cn p" 1 PROPOSED H-20 {DISTRIBUTION BOX MAP 45 LOT 79 Benchmark - a 1S' 50"E �^ ' Nail in 12" Tree o = 1•182 Elev. = 20.00' 1 1 Approx. M.S.L. / ISTING 1,000 GALL EPT`tC TANK TO BE ZED IN N-- STING LEACHING PIT TO BE PUMPED, FILLED wl 4N,,SAND & ABANDONED- J SITE PLAN_ SCALE: 1" = 20' MAP 45 LOT 8 �► sir. l � .��+,.`; . LOCUS PLAN SCALE: 1" = 1000' DESIGN DATA NUMBER OF BEDROOMS (EXISTING) 2 j DESIGN FLOW 110 GAUDAY/BEDROOM TOTAL DESIGN FLOW 220 - _ GAUDAY DESIGN FLOW x 200 % _ 440 GAUDAY USE EXISTING 1,000 GALLON SEPTIC TANK NOT TO BE BACK FILLED WITHOUT FIRST OB 4.83' 3.5' AND DESIGN ENGINEER. (TYP.)8. ELEVATIONS BASED ON APPROXIMATE M.S.L. DATUM. SEE BENCHMARK LOCATION AND ELEVATION SHOWN ON PLAN. 11.83' 9. CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS PRIOR TO CONSTRUCTION CHAM6L_f AND VIEW THROUGH DIG -SAFE AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE AT 1-888-DIG-SAFE AND ANY OTHER APPLICABLE AGENCIES. REPORT ANY DISCREPANCIES TO THE DESIGN ENGINEER. 10. ALL JOINTS WHERE PIPE ENTERS AND EXITS CONC. STRUCTURES SHALL BE MADE WATERTIGHT. 11. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING / TEST PIT DATA REGULATIONS. OWNER/APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM PERC NO. NIN APPROPRIATE AUTHORITY. INSPECTOR: Barry Levris (BOH) 12. ALL SEPTIC SYSTEM COMPONENTS SHALL WITHSTAND H-10 LOADING UNLESS LOCATED UNDER MORE THAN 3 FEET OF COVER OR LOCATED UNDER PAVEMENT, DRIVES, OR EVALUATOR: Michael Pimentel, EIT, CSE TRAVELED WAYS IN WHICH CASE THEY SHALL WITHSTAND H-20 LOADING. 7 2 C.S.E. APPROVAL DATE: Oct. , 1999 ' f 13. DOUBLE WASHED CRUSHED STONE SHALL BE FREE OF ALL DIRT, DUST AND FINES. DATE: January TEST PIT #: 1 14. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL LOAM, SUBSOIL AND UNSUITABLE MATERIAL IN AREA BENEATH AND FOR 5 FT. ON ALL SIDES OF LEACHING FACILITY. j ELEV TOP = 17.50' REPLACE ALL UNSUITABLE MATERIAL WITH CLEAN COARSE SAND FREE FROM CLAY, ELEV WATER = < 3,50' FINES OR OTHER UNSUITABLE MATERIAL IN ACCORDANCE WITH 310 CMR 15.255(3). 15. CONTRACTOR SHALL NOTIFY DESIGN ENGINEER OF ANY DISCREPANCIES FOUND IN PERC RATE _ < 2 min./inch SITE CONDITIONS FROM THOSE SHOWN PRIOR TO CONTINUATION OF WORK. ti DEPTH OF PERC = 30" - 48" 16. PROPOSED PROJECT IS LOCATED WITHIN: TEXTURAL CLASS: I ASSESSOR'S MAP 45 LOT 7 OWNER OF RECORD: YVETTE GRANT WHILBY CHRISTOPHER WHILBY O V 1 a INSTALL 2 - 500 GAL. CHAMBERS w/ STONE SIDEWALL CAPACITY (LENGTH + WIDTH) (2 SIDES) (2' HIGH) (0.74 GPD/S.F.) = GAUDAY (24.0' + 11.83') (2) (2') (0.74 GPD/ S.F.) =106.1 GAUDAY BOTTOM CAPACITY (LENGTH x WIDTH) (0.74 GPD/S.F.) = GAUDAY (24.0' x 11.83') (0.74 GPD/S.F.) = 210.1 GAUDAY TOTALS: TOTAL NUMBER OF CHAMBERS 2 TOTAL LEACHING AREA 427.3 SQ.FT. TOTAL LEACHING CAPACITY 316.2 --,GALJDAY RESERVED FOR BOARD OF HEALTH USE p'. 17.50' Fill 12" 16, 50' B Loamy Sand 10Yr 5/6 30" 15.00' rc 48" 3.50' Med. to Coarse Sand C 2.5Y 6/6 132" 6.50' No Mottling, Standing or Weeping Observed ADDRESS: 168 COMPASS CIRCLE CENTERVILLE, MA 02632 FEMA FLOOD ZONE X COMMUNITY PANEL # 25001C0567J 17. DEED REFERENCE: BOOK 32220, PAGE 212 18. PLAN REFERENCE: P.B. 264, PG. 94 19. ALL DISTURBED AREAS SHALL BE RESTORED TO ORIGINAL CONDITION. 20. PROPERTY LINE INFORMATION IS ONLY APPROXIMATE. THIS PLAN IS TO BE USED ONLY FOR SEPTIC SYSTEM UPGRADE. JC ENGINEERING WILL NOT ASSUME ANY LIABILITY FOR USES OF THIS PLAN OTHER THAN ITS INTENDED PURPOSE. 21. OWNER / APPLICANT / CONTRACTOR SHALL BE RESPONSIBLE TO OBTAIN ANY AND ALL REQUIRED PERMITS AND APPROVALS FOR THIS PROJECT. Yumoa th Department N ® .... Date 50xO' 50 50 5 L 0/H/W - W W -- LSA V 101 RECEWED FEB 20 2024 HEALTH DEPT. EXISTING SPOT GRADE EXISTING CONTOUR PROPOSED CONTOUR PROPOSED SPOT GRADE EXISTING GAS LINE EXISTING OVER HEAD WIRES EXISTING WATER LINE EXISTING LANDSCAPED AREA TEST PIT LOCATION EXISTING 1,000 GALLON SEPTIC TANK PROPOSED 4" SOLID SCHEDULE 40 PVC PIPE PROPOSED H-20 DISTRIBUTION BOX PROPOSED 500 GALLON H-20 LEACHING CHAMBER REV. DATE BY APP'D. DESCRIPTION PROPOSED SEPTIC SYSTEM UPGRADE 10t OF H �1yG PREPARED FOR i JOHN L. CHURCHILL R. ROBERT B. OUR CO., INC. J rni rn LOCATED AT �I .� 4 SOUTH HAWES RUN ROAD YARMOUTH, MA SCALE: 1 INCH = 20 FT. DATE: FEBRUARY 10, 2024 0 10 20 40 80 FEET INA OF - sRc t JOHN L. PREPARED BY cHURc JR. y JC ENGINEERING, INC. 2854 CRANBERRY HIGHWAY EAST WAREHAM, MA 02538 508.273.0377 r / Drawn By: MCP Designed By: MCP Checked By: JLC JOB No. 7540