HomeMy WebLinkAboutBHDC-24-24T.O.F. EL.= 39.9't
FINISH GRADE
@ FND. EL.= 39.0't
-EXISTING:
SEWER PIPE
NTRACTOR TO PROVIDE
ECIFIED DROP BETWEEN
ET AND OUTLET
*CONZ v- , , - , OR TO VERIFY EXISTING
ELEVATION PRIOR TO ANY WORK &
NOTIFY ENGINEER IF DIFFERENT.
PROPOSED EXTENSION RISER
WITH COVER OVER INLET &
OUTLET TO WITHIN 6" OF F.G.
F.G. OVER TANK EL. = 36,5' - 37.0'
PROPOSED 4"
SCH. 40 PVC
SEWER PIPE
611 Tl 3" DROP MAX
_ - - - - - -- 2" DROP MIN 3 9 MIN. sLOPE�?a 1 /
13" 14"
CONTRACTOR CONTRACTOR SHALL OUTLET TEE
SHALL VERIFY SIZE 48" VERIFY CONDITION OF \
AND CONDITION OF EXISTING TEES GAS BAFFLE
EXISTING SEPTIC AND REPLACE AS
TANK NECESSARY
EXISTING 1,500 GALLON CONCRETE SEPTIC TANK
MAP 91 i
1 LOT 47
7
I,
0
Q
0 0.
o.
:.s
� N
1 „
rn` �
G
1
00 1�..
t
i
NOT TO SCALE
i
NOTES:
1. MAGNETIC MARKING TAPE SHALL BE PLACED ALONG THE TOP EDGE OF
EACH SEPTIC SYSTEM COMPONENT.
2. CONTRACTOR SHALL VERIFY SOIL CONDITIONS IN THE LOCATION OF THE
PROPOSED LEACHING FACILITY TO ENSURE CONSISTENCY WITH TEST PIT
DATA SHOWN ON THIS PL,0. REPORT TO ENGINEER AND LOCAL BOARD OF
HEALTH IF SOILS ARE NOT ' ;ONSISTENT WITH TEST PIT DATA.
J WITHIN A DEP APPROVED ZONE II.
9. PROPERTY IS NOT LOCATE
.'S PLAN ARE PROVIDED ONLY AS A COURTESY
4. SWING TIES SHOWN ON Ti 1LLER SHALL VERIFY SWING TIE MEASUREMENTS
FOR THE INSTALLER, INS; PALLING THE SYSTEM. CONTRACTOR SHALL
IN THE FIELD PRIOR TO INa JREMENTS APPEAR TO BE INCORRECT.
NOTIFY ENGINEER IF MEP
FINISH GRADE OVER D-BOX = 35.8't
REMOVABLE WATER -TIGHT COVER OVER
RISER TO WITHIN 6" OF FINISHED GRADE
r5" DIA. OUTLET(S)
9" MIN.
36" MAX.
L-41 t
PROVIDE WATERTIGHT
4" PVC IN FROM JOINTS (TYP.)
SEPTIC TANK 4" PVC OUT TO
.
0 LEACHING FACILITY
32.90' M N. 6 32.73'\'
6" CRtJtHED STONE
OVER MECHANICALLY
COMPACTED BASE
5 OUTLET DISTRIBUTION BOX
TO BE INSTALLED ON A LEVEL STABLE
BASE. FIRST TWO FEET OF OUTLET
PIPES TO BE LAID LEVEL.
CROSS SECTION VIEW
1-RI-1 tET
NOT TO SCALE
ISTING 1,500 GALLON
FINISH GRADE OVER CHAMBERS = 35.5' - 35.9' GENERAL NOTES
SLOPE @ 2% MIN. OVER SYSTEM 3/4" TO 1-1/2" DOUBLE WASHED 1. UNLESS OTHERWISE NOTED, ALL SYSTEM COMPONENTS AND CONSTRUCTION
- 4" SCHEDULE 40 PVC STONE TO CROWN OF PIPE METHODS SHALL BE IN ACCORDANCE WITH TITLE 5 OF THE STATE ENVIRONMENTAL
MIN SLOPE 1% 2" CF 1/8" TO 1/2" DOUBLE WASHED CODE AND ANY APPLICABLE LOCAL RULES.
STONE OR GEOTEXTILE FILTER FABRIC 2. ANY CHANGES TO THIS PLAN MUST BE APPROVED BY THE BOARD OF HEALTH AND THE
DESIGN ENGINEER
TOP OF SAS = 33.50'
32,50' 36" MIAx.
N. BREAKOUT EL = 33.00 ---�
0
0 0 O
0
2'
4.0- I 8.5' (TYP) -I
n_
30.50'
,� EXISTING THREE (3; FLOW DIFFuz
(10'x30'x1') TO BE ABANDONED
(APPROXIMATE LOCATION ONLY)
MAP 91
LOT 57
�X35.3\-PROPOSEDTWO (21-&
GALLON LEACHING
I CHAMBERS w/ STONE
-PROPOSED ---
DISTRIBUTION BOX
IVI/1r J 1
LOT 47
SWING -TIES
DESCRIPTION
HC-1
HC-2
CORNER OF STONE (1)
52.0'
63.0'
CORNER OF STONE (2)
55.4'
54.4'
CORNER OF STONE (3)
79.2'
75.7'
CORNER OF STONE (4)
76.8'
PLACE RISER ON ALL 3. 4" SCHEDULE 40 PVC PIPE WITH WATER TIGHT JOINTS SHALL BE USED IN DISPOSAL
CHAMBERS w/ PIPED SYSTEM UNLESS OTHERWISE NOTED.
INLETS TO WITHIN 6"
OF FINISHED GRADE---' 4• TO PREVENT BREAKOUT, THE PROPOSED FINISHED GRADE SHALL NOT BE LESS THAN
ELEVATION = 33.00' FOR A DISTANCE OF 15AROUND THE PERIMETER OF THE SAS. UNLESS A
40 MIL GEOMEMBRANE LINER IS PLACE AT LEAST FIVE FEET FROM S.A.S. AND THE TOP OF
THE LINER IS NOT LESS THAN THE BREAKOUT ELEVATION.
t7c
8a� O0 5. SLOPE ALL SOLID PIPEAT 1.0% MINIMUM.
6. THIS SYSTEM IS NOT DESIGNED FOR A GARBAGE DISPOSAL.
o oo ...7. -L�BOARD OF HEALTH AND DESIGN -ENGINEER TO BE NOTIFIED PRIOR TO BACK
FILLING WHEN SYSTEM IS NEARLY COMPLETE AND READY FOR INSPECTION. SYSTEM IS
oo oo NOT TO BE BACK FILLED WITHOUT FIRST OBTAINING APPROVAL FROM BOARD OF HEALTH
AND DESIGN ENGINEER.
4.0' 4 0, 4. 0' 8. ELEVATIONS BASED ON APPROXIMATE M.S.L. DATUM. SEE BENCHMARK LOCATION AND
4.83' (TYP. ) ELEVATION AS SHOWN ON PLAN.
9. CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS PRIOR TO CONSTRUCTION
- --- GROUND WATER ELEV.= 24.50 12.83' THROUGH DIG -SAFE AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE AT
2 - 500 GALLON CHAMBERS �� 5' MIN., L,I�r�MBER END VIEVv 1-888-DIG-SAFE AND ANY OTHER APPLICABLE AGENCIES. REPORT ANY DISCREPANCIES
TO THE DESIGN ENGINEER.
TYPICAL CHAMBER PROFILE HAI\ �"> '"' '�'` TAILS 10. ALL JOINTS WHERE PIPE ENTERS AND EXITS CONC. STRUCTURES SHALL BE MADE WATERTIGHT,
NOT TO SCALE 11. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING
SITE PLAN- SWING -TIES & DIMS -
Co -Al C, Vl -')nI SCALE. V = 20'
4
LJII M /Y
TEST PIT DATA
REGULATIONS.WNEOAPPLICANT IS TO OBTAIN SUCH DETERMINATION FROM
APPROP,. AUTHORITY.
• ��
PERC NO. N/A
12,
ALL SEPTIC SYSTEM COMPONENTS SHALL WITHSTAND H-10 LOADING UNLESS LOCATED
INSPECTOR: Barry Lewis (BOH)
UNDER MORE THAN 3 FEET OF COVER OR LOCATED UNDER PAVEMENT, DRIVES, OR
QU
EVALUATOR: Michael Pimentei, EIT, CSE
TRAVELED WAYS IN WHICH CASE THEY SHALL WITHSTAND H-20 LOADING.
O
C.S.E. APPROVAL DATE: Oct. 27, 1999
13.
DOUBLE WASHED CRUSHED STONE SHALL BE FREE OF ALL DIRT, DUST AND FINES.
DATE: January 11, 2024
14.
WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL LOAM, SUBSOIL AND UNSUITABLE
TEST PIT #: 1
MATERIAL IN AREA BENEATH AND FOR 5 FT. ON ALL SIDES OF LEACHING FACILITY.
REPLACE ALL UNSUITABLE MATERIAL WITH CLEAN COARSE SAND FREE FROM CLAY,
ELEV TOP = 35,50'
FINES OR OTHER UNSUITABLE MATERIAL IN ACCORDANCE WITH 310 CMR 15.255(3).
ELEV WATER = < 24.50'
15.
CONTRACTOR SHALL NOTIFY DESIGN ENGINEER OF ANY DISCREPANCIES FOUND IN
SITE CONDITIONS FROM THOSE SHOWN PRIOR TO CONTINUATION OF WORK.
• (
_
PERC RATE < 2 min./inch
`�
16.
PROPOSED PROJECT IS LOCATED WITHIN:
-..
• --
•t (
DEPTH OF PERC = 36" - 54 11
ASSESSOR'S MAP 91 LOT 48
•
LOCUS
TEXTURAL CLASS: I
-
OWNER OF RECORD: IRENE & ALBANO PONTE
•
• ; ; %�•' i%`
gal " • �� ' •
• a
35 50'
ADDRESS: 46 DRIVING TEE CIRCLE
SOUTH YARMOUTH, MA 02664
♦ �l
B
3611
. .
,• • • "♦. P Salt BOX 54"
Beach /
1A7� C
LOCUS PLAN i
SCALE: 1" = 1000'�„
DESIGN DATA
NUMBER OF BEDRO MS (EXISTING) 3
DESIGN FLOW 10 GAL/DAY/BEDROOM
TOTAL DESIGN FLOW L330") GAL/DAY
DESIGN FLOW x 200 % = 660 GAUDAY
USE EXISTING 1,500 GALLON SEPTIC TANK
INSTALL 2 - 500 GAL. CHAMBERS w/ STONE
SIDEWALL CAPACITY
(LENGTH + WIDTH) (2 SIDES) (2' HIGH) (0.74 GPD/S.F,) = GAL/DAY
(25.0' + 12.83') (2) (2') (0.74 GPD/ S.F.) =112.0 GAUDAY
BOTTOM CAPACITY
(LENGTH x WIDTH) (0.74 GPD/S.F.) = GAUDAY
(25.0' x 12.83') (0.74 GPD/S.F.) = 237.4 GAL/DAY
TOTALS:
TOTAL NUMBER OF CHAMBERS 2
TOTAL LEACHING AREA 472.2 SQ.FT.
TOTAL LEACHING CAPACITY 349.4 GAL./DAY
RESERVED FOR BOARD OF HEALTH USE
FEMA FLOOD ZONE X
34.50' COMMUNITY PANEL# 25001CO591J
17. DEED REFERENCE: L.C. CERTIFICATE #142337
18. PLAN REFERENCE: L.C. PLAN #32248-B (SHEET 2)
32.50'
19. ALL DISTURBED AREAS SHALL BE RESTORED TO ORIGINAL CONDITION.
20. PROPERTY LINE INFORMATION IS ONLY APPROXIMATE. THIS PLAN IS TO BE USED ONLY
FOR SEPTIC SYSTEM UPGRADE. JC ENGINEERING WILL NOT ASSUME ANY LIABILITY
FOR USES OF THIS PLAN OTHER THAN ITS INTENDED PURPOSE.
21. OWNER / APPLICANT / CONTRACTOR SHALL BE RESPONSIBLE TO OBTAIN ANY AND ALL
REQUIRED PERMITS AND APPROVALS FOR THIS PROJECT.
24.50' _
No Mottling, Standing or Weeping Dbserved
LEGEND
504'
EXISTING SPOT GRADE
- - 50 - -
EXISTING CONTOUR
0
PROPOSED CONTOUR
50
PROPOSED SPOT GRADE
--- -- AS
EXISTING GAS LINE
0/H/W
EXISTING OVER HEAD WIRES
- W \�
EXISTING WATER LINE
[SA
EXISTING LANDSCAPED AREA
TEST PIT LOCATION
.O O
EXISTING 1,500 GALLON SEPTIC TANK
PROPOSED 4" SOLID SCHEDULE 40 PVC PIPE
Q
PROPOSED DISTRIBUTION BOX
O
PROPOSED 500 GALLON LEACHING CHAMBER
REV._I__ DATE BY
APP'D. DESCRIPTION
PROPOSED SEPTIC SYSTEM UPGRADE
OF Mgsr�c
PREPARED FOR
P�SN
JOHN L. yGs�n
ROBERT B. OUR CO., INC.
a CHURCHILL JR.
CIVIL ^ 1
I' 8066 I
LOCATED AT
JNI
v
46 DRIVING TEE CIRCLE
YARMOUTH, MA
SCALE:
1 INCH = 20 FT. DATE: JANUARY 17, 2024
0
10 20 40 80 FEET
ESN OF MgSS
9cyG
PREPARED BY
L.
CHURCHILL R.
o RCHIJa
JC ENGINEERING, INC.
U �141807 N
2854 CRANBERRY HIGHWAY
r,:
EAST WAREHAM, MA 02538
508,273.0377
Drawn By: MCP Designed By: MCP Checked By: JLC JOB No. 7492