HomeMy WebLinkAboutBHDC-24-189T.O.F. EL.= 42.2'f m FINISH GRADE OVER D-BOX = 38.8± /- PROPOSED EXTENSION RISER WITH COVER OVER INLET & REMOVABLE WATER -TIGHT COVER OVER OUTLET TO WITHIN 6" OF F.G. RISER TO WITHIN 6" OF FINISHED GRADE FINISH GRADE I @ FND. EL.= 41.2'± F.G. OVER TANK EL. = 41.41± (-5" DIA. OUTLET(S) _XiST€NG 4' PROPOSED 4" 9" MIN. �.- SCH. 40 PVC 36" MAX. SEWER PIPr SEWER PIPE 1�tl - t' J 6 3 3tt DROP MAX 3„ 9" L=71't --- PROVIDE WATERTIGHT -��-- .--------------- - 2 DROP MIN - Mw. sLOPE 1°i° ' FROM JOINTS_(TYP.) 14" i SEPTIC TANK 4" PVC OUT TO ' • LEACHING FACILITY ►NTRACTOR TO PROVIDE ECIFIED DROP BETWEEN .ET AND OUTLET CONTRACTOR CONTRACTOR SHALL 12' 6 "t tjN i i` At , i UR TO V LRIFY EXISTINu ELEVATION PRIOR TO ANY WORK & NOTIFY ENGINEER IF DIFFERENT. NOTES: 33 SHALL VERIFY SIZE 48" VERIFY CONDITION OF OUTLET TEE S.SO MIN. 35� AND CONDITION OF EXISTING TEES GAS BAFFLE I EXISTING SEPTIC AND REPLACE AS O CRUSHED STONE TANK NECESSARY � OVER MECHANICALLY COMPACTED BASE j5 OUTLET DISTRIBUTION BOX TO BE INSTALLED ON A LEVEL STABLE EXISTING 1,500 GALLON CONCRETE SEPTIC TANK SEI ! ' ��KIv ORO IL . NOT TO SCALE BASE. FIRST TWO FEET OF OUTLET PIPES TO BE LAID LEVEL. CROSS SECTION VIEW DISTRIE "r)X JETAIL NOT TO SCALE - 4" SCHEDULE 40 PVC MIN SLOPE 1 % 4.0' PROP. 35.20' SEE NOTE 22 _� 1 FINISH GRADE OVER CHAMBERS = 38.2' - 40.2' SLOPE @ 2% MIN. OVER SYSTEM TOP OF SAS = 36.20' BREAKOUT EL = 35.70' 0 0 0CD C) 0 33.20' 1. MAGNETIC MARKING TAPE SHALL BE PLACED ALONG THE TOP EDGE OF EACH SEPTIC SYSTEM COMPONENT. do 2. CONTRACTOR SHALL VERIFY SOIL CONDITIONS IN THE LOCATION OF THE PROPOSED LEACHING FACILITY TO ENSURE CONSISTENCY WITH TEST PIT DATA SHOWN ON THIS PLAN. REPORT TO ENGINEER AND LOCAL BOARD OF HEALTH IF SOILS ARE NOT CONSISTENT WITH TEST PIT DATA. � 1 3. ENTIRE PROPERTY IS LOCATED WITHIN A MASS DEP ZONE II. i 1 t 4. SWING TIES SHOWN ON THIS PLAN ARE PROVIDED ONLY AS A COURTESY FOR THE INSTALLER. INSTALLER SHALL VERIFY SWING TIE MEASUREMENTS IN THE FIELD PRIOR TO INSTALLING THE SYSTEM. CONTRACTOR SHALL NOTIFY ENGINEER IF MEASUREMENTS APPEAR TO BE INCORRECT IN THE FIELD. / r pGP J P��� �N�- ' / / _ - 40 t rr % f MAP 87 1 LOT 173 N N m SS 44'Nq 1 p0.00' r MAP 87 - 41- 16'!� LOT 172 1 HC-1 1 � a��., � 10,500± S.F. 1 31 x41 5 \ 41 \ 1 0 TOF=42.2'± \ ' #17 •� 1 1 E ` tW 4 EXISTING 1 1 \ 3-BEDROOM -4 x41.2 Z \ DWELLING ti _LJ o m M I (FULL BASEMENT) ' I c° 1 z 73 t \ I Ln N 1 40.5 I o `z 18" n x40 c' , p 1l x41.3 j /W40 DF 1 GARAGE V SLAB �' / GV \ (SLAB) - I N GAS \ v \ �" / S GAS GAS GA 11" HC-2 _,_ _- % t ,1 16" \ �- GAS HC-3 / GPS ROPOSED \09 �3 12 GAS 41 r 1 TION BOX (2 (1 3) 15" 41r 1 1 SAS DIMENSIONS SCALE: 1" = 10' SWING -TIES DESCRIPTION HCA 74. ` HC-2 HC-3 27.4 48.9 CORNER OF STONE (1) 10.2' 28.4' CORNER OF STONE (2) 69,7- 71 10.9' 25.3' CORNER OF STONE (3) 21.8' 31.4' CORNER OF STONE (4) 82. ' 33.8' 52.6' CORNER OF STONE (5) 86 - MAP 87 LOT 173 8.5 0 C 00 C) 0 PROP. VENT WITH CHARCOAL FILTER TO ABOVE GRADE 3/4" TO 1-1/2" DOUBLE WASHED STONE TO CROWN OF PIPE 2" OF 1/8" TO 1/2" DOUBLE WASHED STONE OR GEOTEXTILE FILTER FABRIC PLACE RISER ON ALL CHAMBERS w/ PIPED INLETS TO WITHIN 6" OF FINISHED GRADE 0 �7 C O 0 D o 0 CD 0 o 0 VARIES - GROUND WATER ELEV= < 27.80' 2 - 500 GALLON CHAMBERS 5' MIN. TYPICAL CHAMBER PROFILE PROPOSED 12" x38 5 4 kLL0N��-26�;LEACHING TP_' 40, CHAMBERS w/ STONE . ,.. .� gITF PI AN SCALE: 1" = 10' H-20 CH," DETAILS NOT TO SCALE O IN14RCHA LOCUS PLAN SCALE: 1" = 1000' NUMBER OF BEDROOMS (EXISTIN 3 DESIGN FLOW 110 GAUD )EDROOM TOTAL DESIGN FLOW 330 GAUDAY DESIGN FLOW x 200 % = 660� GAUDAY U USE EXISTING 1,500 GALLON SEPTIC TANK INSTALL 2 - 500 GAL. CHAMBERS w/ STONE SIDEWALL CAPACITY (TOTAL PERIMETER) (2' HIGH) (0.74 GPD/S.F.) = GAUDAY (74.2') (2') (0.74 GPD/ S.F.) = 109.8 GAUDAY BOTTOM CAPACITY (FOOTPRINT AREA) (0.74 GPD/S.F.) = GAL/DAY (316.9 S.F.) (0.74 GPD/S. F.) = 234.5 GAUDAY TOTALS: TOTAL NUMBER OF CHAMBERS 2 TOTAL LEACHING AREA 465. SQ.FT. TOTAL LEACHING CAPACITY 344.3 GAL./DAY RESERVED FOR BOARD OF HEALTH USE 4.83' (TYP.) VARIES Twit lr-uviLv .X� LND VIEW TEST PIT DATA PERC NO. INSPECTOR: Barry Lewis (BOH) EVALUATOR: Michael Pimentel, EIT, CSE C.S.E. APPROVAL DATE: Oct. 27, 1999 DATE: Sept` ember , 2024 TEST PIT #: 1 ELEV TOP = 38.80' ELEV WATER = < 27.80' PERC RATE _ < 2 min./inch DEPTH OF PERC = 36" - 54" TEXTURAL CLASS: I 0" 38.80' Fill 6" 38.30' A Loamy Sand 12" 10Yr 5/1 37.80' Loamy Sand 10Yr 5/6 Med. to Coarse Sand 2.5Y 6/6 u 36" 35.80' 5a. 132" 27.80' No Mottling, Standing or Weeping Observed 1. UNLESS OTHERWISE NOTED. ALL SYSTEM COMPONENTS AND CONSTRUCTION METHODS SHALL BE IN ACCORDANCE WITH TITLE 5 OF THE STATE ENVIRONMENTAL CODE AND ANY APPLICABLE LOCAL RULES. 2. ANY CHANGES TO THIS PLAN MUST BE APPROVED BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 3. 4" SCHEDULE 40 PVC PIPE WITH WATER TIGHT JOINTS SHALL BE USED IN DISPOSAL SYSTEM UNLESS OTHERWISE NOTED. 4. TO PREVENT BREAKOUT, THE PROPOSED FINISHED GRADE SHALL NOT BE LESS THAN ELEVATION = 35.70' FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE SAS. UNLESS A 40 MIL GEOMEMBRANE LINER IS PLACE AT LEAST FIVE FEET FROM S.A.S. AND THE TOP OF THE LINER IS NOT LESS THAN THE BREAKOUT ELEVATION. 5. SLOPE ALL SOLIC7 o UM. THIS SYSTEM I OT DESIGNED FOR A GARBAGE DISPOSAL. �7. LOCAL BOARD OF HEALTH AND DESIGN ENGINEER TO BE NOTIFIED PRIOR TO BACK FILLING WHEN SYSTEM IS NEARLY COMPLETE AND READY FOR INSPECTION. SYSTEM IS NOT TO BE BACK FILLED WITHOUT FIRST OBTAINING APPROVAL FROM BOARD OF HEALTH AND DESIGN ENGINEER. 8. ELEVATIONS BASED ON NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD 88). SEE BENCHMARK LOCATION AND ELEVATION AS SHOWN ON PLAN. 9. CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS PRIOR TO CONSTRUCTION THROUGH DIG -SAFE AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE AT 1-888-.DIG-SAFE AND ANY OTHER APPLICABLE AGENCIES. REPORT ANY DISCREPANCIES TO THE DESIGN ENGINEER. 10. ALL JOINTS WHERE PIPE ENTERS AND EXITS CONC. STRUCTURES SHALL BE MADE WATERTIGHT. 11. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING REGULATIONS. OWNER/APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. 12. ALL SEPTIC SYSTEM COMPONENTS SHALL WITHSTAND H-10 LOADING UNLESS LOCATED UNDER MORE THAN 3 FEET OF COVER OR LOCATED UNDER PAVEMENT, DRIVES, OR TRAVELED WAYS IN WHICH CASE THEY SHALL WITHSTAND H-20 LOADING. 13. DOUBLE WASHED CRUSHED STONE SHALL BE FREE OF ALL DIRT, DUST AND FINES. 14. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL LOAM, SUBSOIL AND UNSUITABLE MATERIAL IN AREA BENEATH AND FOR 5 FT. ON ALL SIDES OF LEACHING FACILITY. REPLACE ALL UNSUITABLE MATERIAL WITH CLEAN COARSE SAND FREE FROM CLAY, FINES OR OTHER UNSUITABLE MATERIAL IN ACCORDANCE WITH 310 CMR 15.255(3). 15. CONTRACTOR SHALL NOTIFY DESIGN ENGINEER OF ANY DISCREPANCIES FOUND IN SITE CONDITIONS FROM THOSE SHOWN PRIOR TO CONTINUATION OF WORK. 16. PROPOSED PROJECT IS LOCATED WITHIN: ASSESSOR'S MAP 87 LOT 172 OWNER OF RECORD: AKTOV LLC ADDRESS: 66 PONDSIDE CIRCLE CENTERVILLE MA 02632 FEMA FLOOD ZONE X COMMUNITY PANEL # 25001C0587J 17. DEED REFERENCE: BOOK29651, PAGE 93 18. PLAN REFERENCE: P.B. 222, PG. 143 19. ALL DISTURBED AREAS SHALL BE RESTORED TO ORIGINAL CONDITION. 20. PROPERTY LINE INFORMATION IS ONLY APPROXIMATE. THIS PLAN IS TO BE USED ONLY FOR SEPTIC SYSTEM UPGRADE. JC ENGINEERING WILL NOT ASSUME ANY LIABILITY FOR USES OF THIS PLAN OTHER THAN ITS INTENDED PURPOSE. 21. OWNER / APPLICANT / CONTRACTOR SHALL BE RESPONSIBLE TO OBTAIN ANY AND ALL REQUIRED PERMITS AND APPROVALS FOR THIS PROJECT. 22. IN ACCORDANCE WITH 310 CMR 15.401-15.405, THE FOLLOWING LOCAL UPGRADE APPROVAL IS REQUESTED FROM 310 CMR 15.221(7): (1.) A 1.0' WAIVER (3.0' - 4.0') FOR THE MAXIMUM COVER OVER THE H-20 SAS. �50 50 GAS -- Yarmopth $ �1 ------ t" QED -LSA- NameDate OCT 18 2024 O HEALTH DEPT REV. DATE tH OF t%4S� r° JOHN L. V' c CHURCHILL JR. v CIVIL to NO- 48066 �LYtk OF y4S JOHN L. °ri CHURCHILL JR. c CIVIL NC ''807 EXISTING SPOT GRADE EXISTING CONTOUR PROPOSED CONTOUR PROPOSED SPOT GRADE EXISTING GAS LINE EXISTING OVERHEAD UTILITIES EXISTING WATER LINE EXISTING LANDSCAPED AREA TEST PIT LOCATION EXISTING 1,500 GALLON SEPTIC TANK PROPOSED 4" SOLID SCHEDULE 40 PVC PIPE PROPOSED DISTRIBUTION BOX PROPOSED 500 GALLON H-20 LEACHING CHAMBER BY APP'0. I DESCRIPTION PROPOSED SEPTIC SYSTEM UPGRADE PREPARED FOR ROBERT B. OUR CO., INC. LOCATED AT 17 QUARTERMASTER ROW YARMOUTH, MA SCALE: 1 INCH = 10 FT. DATE: OCTOBER 11, 2024 0 5 10 20 40 FEET PREPARED BY JC ENGINEERING, INC. 2854 CRANBERRY HIGHWAY EAST WAREHAM, MA 02538 508.273.0377 Drawn By: JTC Designed By: MCP Checked By: JLC JOB No. 8093