Loading...
HomeMy WebLinkAboutSEPTIC PLAN BLD. APROPOS OF FOUP ELEVATION = LOCUS SCALE 1"=750' - LOCUS . SEPTIC TANK EXISTING SEPTIC TANK 1ST FLOOR SITE LOCUS SCALE 1 "- 300' NOTE: A SECOND PERCOLATION TEST SHALL BE PERFORMED AT TIME OF INSTALLATION OF THE SEPTIC SYSTEM IN THE C2 LAYER, FINE SAND. " I � 99.92 MAG NAIL ` 0� j1 1 90.85 '100.01 PAVED PARKING \ \0 Fact I AREA OP \ < 1 x 99.60 x 100.4 \70, x 99.21 Ilil 100.55 -� 098.78ul I III \ I 100.30 rm*t 99.44 I I \ ' p 99.81 ` 1 co x 99.68 I \ / 1 4. r_ .' EXISTING 2,000 N m 4� GAL. TANK TO o o REMAIN / �83^1, x 9;_.3 00 OHO 99.87 L, '`.,� (5) PROPOSED t�►, O `�� 500-GALLON PRECAST r I i mho / CONCRETE CHAMBERS o 3121 (H20) IN A 12.83' X 99.51 50.50' BED OF STONE o �) 1, '�hp rn x 99.76PROPOSED Vl VENT o 1-1 x 100.66 I I } O ;..:n -1 z f 100.26 I)' a x' �' AREAOSEDOF S ASS DTO IN 99.7 O ;' =^'� 'MATCH EXISTING GRADES Dc x 99.64 III p4' EXISTING LEACHFIELD 98 07 TO BE REMOVED x 99.27 �� 9• O �. i PROPOSED 9-OU�LET � }' f ' . +'•.`� DISTRIBUTION BOX (H O) _PROPOSED VENT PROPOSED 2,000 0 TP2 GALLON PRECAST ::,^' �_7hJ� 97.76 CONCRETE SEPTIC 99.81 / •: I / TANK (H 10) (5) PROPOSED 500-GALLON PRECAST 0 I / CONCRETE CHAMBERS /98.73 50 50' I BED OF BSTONE :/ I BENCHMARK x 97 38 -' W MAG NAIL SET ELEV. = 99.45 MIN. 10' SEPARATION To v 50 WATER SERVICE OR MAIN (TYP.) - - A 1F0 To cgMA x 96.36 F�qr sT�� x 95.38 Permit valid fur REPAIR OF SEPTIC SY'SITEM ONLI , title 11, and Local septic variances. Board tot Ilealth I1 I ICN ;Ind approtal 1% required for any futulc u1J11n nc�renu�a11UI1�i:Illcrat1tl/1S to sewage laclBtle. alldiol %tructures/d»cllulg. Yarmouth llcalth Departtl►cnt APPROVILll Name Date CL SEPTIC TANK PROPOSED JI :N i LIVING ROOM DINING ROOM KITCHEN RISERS ON INLET TO BE BROUGHT TO SYSTEM PROFILE NOT TO SCALE 2ND FLOOR w BEDROOM 0 U CL BATH BATH STUDIO/DEN CL FRONT FRONT FLOOR PLAN NOT TO SCALE 0" 12" 28" 70" '26" TP HTM B LOAMY M. SAND 1OYR 4/6 C1 COARSE SAND 10YR 6/3 C2FINE SAND 2.5Y 6/3 87.57 MOTTLING: NONE WEEPING: NONE 98.07 0" 97.07 12" 95.73 29" 70" 126" 111161 1; 1lei z •. RISER ON D-BOX TO SITE INFORMATION ADDRESS: 193 CAMP STREET, UNIT A, YARMOUTH MA ASSESSORS MAP/LOT: 53/6.1 DEED BOOK/PG 4572/155 PLAN BOOK/PG 388/27 DESIGN CALCULATIONS DESIGN FLOW 110 GALLONS/DAY/BEDROOM X 12 BEDROOMS = 1,320 GALLONS/DAY TANK CAPACITY 1ST COMP (48 HR. DETENTION TIME) = 2,640 GALLONS 2ND COMP (24 HR. DETENTION TIME) = 1,320 GALLONS = 3,960 GALLONS USE EXISTING 2,000 GALLON TANK AND ADD PROPOSED 2,000 GALLON TANK REQUIRED LEACHING CAPACITY DESIGN PERC RATE = < 2 MIN/INCH 1,320 GPD / 0.74 GALLONS PER DAY PER SQ. FT. = 1,783.78 SQ. FT. PROVIDED PROVIDED LEACHING CAPACITY BOTTOM AREA = 50.50' X 12.83' = 647.92 SQ. FT. SIDE AREA = 126.66' X 2.00' = 253.32 SQ. FT. = 901.24 SQ. FT. PROVIDE TWO LEACHING FACILOY- 1,802.48 SQ. FT. PROVIDED FLOW CAPACITY = 1,333.83 GPD Ve TP2 HTM B LOAMY M. SAND 1OYR 4/6 C1 COARSE SAND 10YR 5/4 PERC O 56" C FINE/MED SAND 10YR 6/3 87.26 MOTTLING: NONE WEEPING: NONE PERC RATE: <2 MIN./IN. SOIL PROFILES DATE: JANUARY 16, 2020 PERFORMED BY: RICHARD JUDD (SE 1165) WITNESSED BY: MALLORY LANGLER NOT TO SCALE 97.76 96.76 95.34 91.92 RIQCRQ MI ru A►JQ=C nAIC ru ALAPr D 3.98 GROUNDWATER NOT OBSERVED DURING OBSERVATION HOLES GENERAL NOTES: 1. NONE OF THE SUBJECT PROPERTY IS WITHIN THE LIMITS OF A FEMA FLOOD HAZARD ZONE AS SHOWN ON PANEL NO. 25001 CO567J, EFFECTIVE DATE JULY 16, 2014. 2. THE SITE IS LOCATED WITHIN A ZONE 11 AREA. 3. THERE ARE NO STREAMS OR WETLANDS WITHIN 100-FEET OF THE PROPOSED SUBSURFACE SEWAGE DISPOSAL SYSTEM. 4. VERTICAL DATUM IS ASSUMED 5. ALL CONSTRUCTION MEANS AND METHODS SHALL CONFORM TO 310 CMR 15.00 STATE REGULATIONS AND LOCAL BOARD OF HEALTH AND BUILDING DEPARTMENT REGULATIONS. 6. ALL JOINTS IN THE TANK AND DISTRIBUTION BOX SHALL BE MADE WATERTIGHT THROUGH THE USE OF ASPHALT OR SYNTHETIC POLYMER SEALERS OR HYDRAULIC CEMENT. 7. SYSTEM COMPONENTS SHALL BE H-20 LOADING WHERE NOTED 8. DIGSAFE AND LOCAL UTILITY COMPANIES SHALL BE CONTACTED PRIOR TO ANY EXCAVATION OCCURRING. 9. LOCATION OF UTILITIES ON THIS PLAN ARE APPROXIMATE AND SHALL BE VERIFIED IN THE FIELD. THE INVERT ELEVATIONS OF THE EXISTING SYSTEM COMPONENTS PROPOSED TO BE REUSED SHALL BE VERIFIED PRIOR TO INSTALLATION OF ANY NEW COMPONENTS. ANY DISCREPANCIES SHALL BE REPORTED TO THE ENGINEER 10. THE SEPTIC SYSTEM INSTALLER SHALL NOTIFY THE DESIGN ENGINEER 2 DAYS PRIOR TO BEGINNING INSTALLATION OF THE SYSTEM TO ALLOW FOR SCHEDULING OF INSPECTIONS 11. WHERE APPLICABLE, UNSUITABLE MATERIAL (A & B HORIZONS) ENCOUNTERED BELOW THE INVERT OF THE INLET TO THE SOIL ABSORPTION SYSTEM, SHALL BE REMOVED TO A DISTANCE 5' AROUND THE SYSTEM AND BROUGHT BACK TO THE APPROPRIATE ELEVATION WITH CLEAN SAND PER MASSACHUSETTS 310 CMR 15.00 REGULATIONS. 12. THIS DESIGN DOES NOT ALLOW FOR THE USE OF A GARBAGE GRINDER 13. THE SOILS IN THE AREA OF THE SOIL ABSORPTIONS SYSTEM SHALL BE FIELD VERIFIED DURING TIME OF CONSTRUCTION TO ENSURE CONSISTENCY WITH OBSERVATION HOLES PERFORMED. 14. EXISTING CONDITIONS SURVEY PERFORMED BY PAUL E. SWEETSER, PLS PO BOX 1146 DENNISPORT MA 02639 IN JANUARY 2020 LEGEND PROPERTY LINE EXISTING CONTOUR -- 104 PROPOSED CONTOUR ---- EXISTING FENCE EXISTING OVERHEAD UTILITIES ------'�"-- -- EXISTING WATER LINE - W PROPOSED WATER LINE G PROPOSED NATURAL GAS LINE UGE PROPOSED UNDERGROUND POWER/TELCOM TP LOCATION OF TEST PIT/PERC TEST EXISTING SPOT ELEVATION QFH EXISTING FIRE HYDRANT UP EXISTING UTILITY POLE BH BULKHEAD 101.50 PROPOSED SPOT GRADE ❑T EXISTING TRANSFORMER 4 CRESTVIEW DRIVE EAST SANDWICH, MA 02537 A =_rlVl PHONE: (508) 400-2365 SITE DESIGN, LLC Residential Site Design and Permitting LOC4T/ON.• 193 CAMP STREET (UNIT A) YARMOUTH, MA CLIENT DAVENPORT REALTY TRUST 20 NORTH MAIN STREET SOUTH YARMOUTH, MA 02664 DRAWING TITLE. SUBSURFACE SEWAGE DISPOSAL SYSTEM SITE PLAN AND PROFILE scgLE• T3��3/7/2020 DRAWING No.1 "=20' -L of _L REVISIONS NO. DATE DESCRIPTION