Loading...
HomeMy WebLinkAboutEngineer Report - repairs 11/4/24 MICHELE CUDILO, P.E. Consulting Structural Engineer 123 Cottonwood Lane,Centerville, Massachusetts 02632-1979• (508)737-8521 •mcudilo@ccmcast.net November 4,2024 Ms.Johnson West Yarmouth Series LLC POB 342 Hyannis, MA 02601 RE: Egress Inspection: BEACH BERRY INN 157 BERRY AVE.,Yarmouth,MA Dear Steve, The following items were observed during Site Observation 01 on November 1, 2024,and require follow-up construction,as discussed with you. REAR STAIRS/DECKS 1. Replace rusted joist hangers and lag bolts:use Simpson LU26(min.)and 2-Ledgerlok per 16" bay. The following criteria are required in your future maintenance. Any newly constructed rails shall meet the current criteria: 1. Height of Rail at upper floors: 42"above decking; 2. Spacing between balusters: 4" clear max.;not ladder-type; 3. Max.triangular space between stair parts: 6"sphere. 4. All components shall be capable of withstanding a 200 lb. load in any direction. 5. Height of rail above the leading edge of stair tread: 42" 6. Stair treads to have 1" nosing over riser Please call for final review of the above corrected conditions in the field for final observation. Sincerely, Michele Cudilo, P.E. /2024-314 qj ittj r 1 0